Literature DB >> 1386573

Amplitude analysis of stress technetium-99m methoxy isobutylisonitrile images in coronary artery disease.

E E Camargo1, F H Hironaka, M C Giorgi, J Soares Júnior, J C Meneguetti, R Abe, C C Robilotta, A C Munhoz, H Checchi, J A Ramirez.   

Abstract

To determine the role of rest and stress gated technetium-99m methoxyisobutylisonitrile (sestamibi), in the detection of coronary artery disease, routine Fourier analysis of these images was performed with the best septal left anterior oblique (LAO) position of 20 patients (17 men, 3 women; aged 40-75 years) who also underwent rest or redistribution/stress single photon emission tomography (SPET) (99mTc-sestamibi and Thallium-201), gated blood pool imaging and coronary angiogram. There were 6 patients with single-vessel disease, 6 with two-vessel disease, 4 with three-vessel disease, 2 with coronary spasms, 1 with a patent graft and 1 with anginal episodes but a normal angiogram result. Three normal volunteers (2 women, 1 man; aged 24-26 years) also had rest and stress gated blood pool as well as rest and stress gated 99mTc-sestamibi imaging. Rest and stress 99mTc-sestamibi amplitude and phase images depicted regional myocardial wall shortening from the outer layer of the myocardium to the center of the left ventricle as follows: a high amplitude halo of maximal negative count rate variation; a circular thinner halo of negligible amplitude; a central region of maximal positive count rate variation, as the images evolved from end-diastole to end-systole. Similar patterns with regional differences represented abnormal myocardial wall shortening. 99mTc-sestamibi and 201Tl SPET images were in agreement in 90% of the patients and 92% of myocardial regions. 201Tl SPET detected 83% of angiographically proven lesions, as compared with 80% for 99mTc-setamibi SPET and 80% for the amplitude images. The amplitude images demonstrated a larger number of other abnormalities not predicted on the angiogram, probably because they were able to detect regions with a potential for flow improvement and transient regional wall shortening abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1386573     DOI: 10.1007/bf00185853

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  18 in total

1.  Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

Authors:  J K Kahn; I McGhie; M S Akers; M N Sills; T L Faber; P V Kulkarni; J T Willerson; J R Corbett
Journal:  Circulation       Date:  1989-06       Impact factor: 29.690

2.  The contraction fraction (CF) in myocardial studies with technetium-99m-isonitrile (MIBI)--correlations with radionuclide ventriculography and infarct size measured by SPECT.

Authors:  M Clausen; E Henze; A Schmidt; R Weller; R Lietzenmayer; D Hellwig; F Bitter; P Hildebrand; V Hombach; W E Adam
Journal:  Eur J Nucl Med       Date:  1989

3.  Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi.

Authors:  E V Garcia; C D Cooke; K F Van Train; R Folks; J Peifer; E G DePuey; J Maddahi; N Alazraki; J Galt; N Ezquerra
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

4.  Detection and location of myocardial infarction using technetium-99m sestamibi imaging at rest.

Authors:  C A Boucher
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

5.  Planar imaging techniques used with technetium-99m sestamibi to evaluate chronic myocardial ischemia.

Authors:  M N Maisey; R Mistry; E Sowton
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

6.  99mTc-MIBI (RP-30) to define the extent of myocardial ischemia and evaluate ventricular function.

Authors:  M P Larock; R Cantineau; V Legrand; H Kulbertus; P Rigo
Journal:  Eur J Nucl Med       Date:  1990

7.  Simultaneous measurement of left ventricular function and perfusion.

Authors:  A T Elliott; J H McKillop; S D Pringle; G J Gillen; J T Wilson; A R Lorimer; H J Dargie
Journal:  Eur J Nucl Med       Date:  1990

8.  Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT.

Authors:  J Villanueva-Meyer; I Mena; K A Narahara
Journal:  J Nucl Med       Date:  1990-04       Impact factor: 10.057

9.  Biological studies of a new class of technetium complexes: the hexakis(alkylisonitrile)technetium(I) cations.

Authors:  A G Jones; M J Abrams; A Davison; J W Brodack; A K Toothaker; S J Adelstein; A I Kassis
Journal:  Int J Nucl Med Biol       Date:  1984

10.  Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging.

Authors:  A S Iskandrian; J Heo; B Kong; E Lyons; S Marsch
Journal:  Am J Cardiol       Date:  1989-08-01       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.