Literature DB >> 7053889

Factors that affect the reproducibility of measurements of left ventricular function from first-pass radionuclide ventriculograms.

D S Dymond, A Elliott, D Stone, G Hendrix, R Spurrell.   

Abstract

To examine which factors affect the reproducibility of ejection fraction (EF), pulmonary transit time (PTT) and segmental wall motion assessed from first-pass radionuclide angiograms (FPRA), 32 patients who had FPRA were randomized for site of injection of isotope (right or left arm) and projection (right or left anterior oblique [RAO or LAO]). The quality of injected bolus was measured from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. All patients had two sequential studies on each of two consecutive days, and each study was analyzed independently by two observers. For EF, inter- and intraobserver correlations ranged from 0.94-0.98. EF was higher in the RAO than the LAO projection (mean 47.4% vs 40.3%, p less than 0.001), but neither injection site nor bolus FWHM affected the results. For PTT, interobserver correlations ranged from 0.75-0.93 and intraobserver correlations from 0.61-0.85. Variability in PTT was large, and inter- and intraobserver variabilities were directly related to bolus FWHM (mean 0.60 +/- 0.21 second for interobserver differences in PTT of less than 2.0 seconds, mean 1.55 +/- 0.86 seconds for interobserver differences in PTT of greater than 2 seconds [p less than 0.005]). Differences in FWHM between sequential studies were 0.28 +/- 0.29 second when intraobserver differences in PTT were less than 2 seconds and 1.04 +/- 0.67 seconds when differences in PTT were greater than 2.0 seconds (p less than 0.005). Variations in PTT were not related to differences in projection or injection site. Wall motion was highly reproducible for both projections. In the RAO projection, one of 116 anterior segments (0.9%), one of 116 apical segments (0.9%), and four of 116 inferior segments (3%) were judged normal from one observer's images and abnormal from another. In the LAO view, discrepancies occurred in one of 126 septal segments (0.8%), two of 126 apical segments (1.6%) and four of 126 posterolateral segments (3%). This study shows that EF and wall motion are highly reproducible in any projection, but the choice of projection significantly affects the values for EF from FPRA. PTT measurements are less reliable, highly bolus dependent, and their use in clinical practice depends on quality control of the bolus of injected radionuclide.

Entities:  

Mesh:

Year:  1982        PMID: 7053889     DOI: 10.1161/01.cir.65.2.311

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

1.  Repeatability of treadmill exercise ejection fraction and wall motion using technetium 99m-labeled sestamibi first-pass radionuclide ventriculography.

Authors:  B Benari; H Kiat; J Erel; M Hyun; F P Wang; C Williams; J D Friedman; G Germano; K F Van Train; D Berman
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

2.  Influence of respiratory variations on right ventricular function.

Authors:  J L Caplin; W D Flatman; L Dyke; M N Wiseman; D S Dymond
Journal:  Br Heart J       Date:  1989-10

3.  The reliability of measuring left ventricular ejection fraction by radionuclide cardiography: evaluation by the method of variance components.

Authors:  P F Høilund-Carlsen; S L Lauritzen; J Marving; S Rasmussen; B Hesse; K Folke; J Godtfredsen; B Chraemmer-Jørgensen; N Gadsbøll; H Dige-Petersen
Journal:  Br Heart J       Date:  1988-06

4.  Effects of projection and background correction method upon calculation of right ventricular ejection fraction using first-pass radionuclide angiography.

Authors:  J L Caplin; W D Flatman; D S Dymond
Journal:  Int J Card Imaging       Date:  1985

5.  Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography.

Authors:  E Vallejo; D P Dione; A J Sinusas; F J Wackers
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

6.  Assessment of left ventricular ejection fraction measured by quantitative gated SPECT: correlation with left ventriculography and first-pass radionuclide angiography.

Authors:  Koichiro Abe; Koichi Hirakawa; Takenori Yonenaga; Satoshi Kobayashi; Masao Nishimura; Zenji Ayabe
Journal:  Int J Cardiovasc Imaging       Date:  2005-10-18       Impact factor: 2.357

7.  Global and regional right ventricular function after acute myocardial infarction: dependence upon site of left ventricular infarction.

Authors:  J L Caplin; D S Dymond; W D Flatman; R A Spurrell
Journal:  Br Heart J       Date:  1987-08

8.  Novel approach to the interpretation of long-term "deterioration" in ejection fraction in individual patients with coronary artery disease.

Authors:  R Lim; L Dyke; J Thomas; D S Dymond
Journal:  Br Heart J       Date:  1993-09

9.  Simultaneous measurement of left ventricular function and perfusion.

Authors:  A T Elliott; J H McKillop; S D Pringle; G J Gillen; J T Wilson; A R Lorimer; H J Dargie
Journal:  Eur J Nucl Med       Date:  1990

10.  Technically suboptimal first-pass radionuclide angiographic studies.

Authors:  R Gal; R P Grenier; D H Schmidt; S C Port
Journal:  Eur J Nucl Med       Date:  1990
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.