Literature DB >> 22843309

Reliability evaluation of alumina-blasted/acid-etched versus laser-sintered dental implants.

Erika O Almeida1, Amilcar C Freitas Júnior, Estevam A Bonfante, Nelson R F A Silva, Paulo G Coelho.   

Abstract

Step-stress accelerated life testing (SSALT) and fractographic analysis were performed to evaluate the reliability and failure modes of dental implant fabricated by machining (surface treated with alumina blasting/acid etching) or laser sintering for anterior single-unit replacements. Forty-two dental implants (3.75 × 10 mm) were divided in two groups (n=21 each): laser sintered (LS) and alumina blasting/acid etching (AB/AE). The abutments were screwed to the implants and standardized maxillary central incisor metallic crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized light and scanning electron microscopes were used for failure analyses. The Beta (β) value derived from use-level probability Weibull calculation of 1.48 for group AB/AE indicated that damage accumulation likely was an accelerating factor, whereas the β of 0.78 for group LS indicated that load alone likely dictated the failure mechanism for this group, and that fatigue damage did not appear to accumulate. The reliability was not significantly different (p>0.9) between AB/AE (61 %) and LS (62 %). Fracture of the abutment and fixation screw was the chief failure mode. No implant fractures were observed. No differences in reliability and fracture mode were observed between LS and AB/AE implants used for anterior single-unit crowns.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22843309     DOI: 10.1007/s10103-012-1170-8

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  40 in total

Review 1.  Clinical complications of osseointegrated implants.

Authors:  C J Goodacre; J Y Kan; K Rungcharassaeng
Journal:  J Prosthet Dent       Date:  1999-05       Impact factor: 3.426

2.  Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces.

Authors:  W O Soboyejo; B Nemetski; S Allameh; N Marcantonio; C Mercer; J Ricci
Journal:  J Biomed Mater Res       Date:  2002-10

3.  Laboratory simulation of Y-TZP all-ceramic crown clinical failures.

Authors:  P G Coelho; E A Bonfante; N R F Silva; E D Rekow; V P Thompson
Journal:  J Dent Res       Date:  2009-04       Impact factor: 6.116

4.  The early osseointegration of the laser-treated and acid-etched dental implants surface: an experimental study in rabbits.

Authors:  Mingdeng Rong; Lei Zhou; Zehong Gou; Andi Zhu; Dongfeng Zhou
Journal:  J Mater Sci Mater Med       Date:  2009-03-17       Impact factor: 3.896

5.  Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.

Authors:  Amilcar C Freitas; Estevam A Bonfante; Eduardo P Rocha; Nelson R F A Silva; Leonard Marotta; Paulo G Coelho
Journal:  Eur J Oral Sci       Date:  2011-08       Impact factor: 2.612

6.  Osseointegration on metallic implant surfaces: effects of microgeometry and growth factor treatment.

Authors:  Sally R Frenkel; Jordan Simon; Harold Alexander; Michael Dennis; John L Ricci
Journal:  J Biomed Mater Res       Date:  2002

7.  Implant treatment in partially edentulous patients: a report on prostheses after 3 years.

Authors:  J Gunne; T Jemt; B Lindén
Journal:  Int J Prosthodont       Date:  1994 Mar-Apr       Impact factor: 1.681

8.  Effect of water storage time and composite cement thickness on fatigue of a glass-ceramic trilayer system.

Authors:  Nelson R F A Silva; Grace M de Souza; Paulo G Coelho; Christian F J Stappert; Elizabeth A Clark; Elizabeth D Rekow; Van P Thompson
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-01       Impact factor: 3.368

9.  Influence of loading frequency on implant failure under cyclic fatigue conditions.

Authors:  Matthias Karl; J Robert Kelly
Journal:  Dent Mater       Date:  2009-07-29       Impact factor: 5.304

10.  Reliability and failure modes of implant-supported Y-TZP and MCR three-unit bridges.

Authors:  Estevam Augusto Bonfante; Paulo Guilherme Coelho; Jose Manuel Navarro; Luiz Fernando Pegoraro; Gerson Bonfante; Van Purdy Thompson; Nelson Renato Franç Alves Silva
Journal:  Clin Implant Dent Relat Res       Date:  2009-03-31       Impact factor: 3.932

View more
  3 in total

1.  Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients.

Authors:  Francesco Guido Mangano; Michele De Franco; Alberto Caprioglio; Aldo Macchi; Adriano Piattelli; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2013-03-15       Impact factor: 3.161

2.  Reliability and failure modes of narrow implant systems.

Authors:  Ronaldo Hirata; Estevam A Bonfante; Rodolfo B Anchieta; Lucas S Machado; Gileade Freitas; Vinicius P Fardin; Nick Tovar; Paulo G Coelho
Journal:  Clin Oral Investig       Date:  2015-11-03       Impact factor: 3.573

Review 3.  Direct metal laser sintering titanium dental implants: a review of the current literature.

Authors:  F Mangano; L Chambrone; R van Noort; C Miller; P Hatton; C Mangano
Journal:  Int J Biomater       Date:  2014-12-01
  3 in total