Literature DB >> 21726295

Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.

Amilcar C Freitas1, Estevam A Bonfante, Eduardo P Rocha, Nelson R F A Silva, Leonard Marotta, Paulo G Coelho.   

Abstract

The mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; Colosso Evolution system) were divided into four groups (n=21 each): screw-retained and internal connection (Si), screw-retained and external connection (Se), cement-retained and internal connection (Ci), and cement-retained and external connection (Ce). Ti-6Al-4V abutments were torqued (30 Ncm) to the implants, and maxillary central incisor metal crowns were torqued (30 Ncm) or cemented (Rely X Unicem; 3M-ESPE) and subjected to accelerated life-testing in water. Use-level probability Weibull curves and reliability for 50,000 cycles at 150 N were calculated. The β values for Si (1.72), Se (1.50), Ci (1.34), and Ce (1.77) groups indicated that fatigue/damage accumulation accelerated their failure. The Ci group presented the highest reliability, the Se group presented the lowest reliability, and Si and Ce groups presented intermediate reliability. Screw-retained restorations presented mainly abutment fracture. Cement-retained restorations resulted in failures of the screw in the Ce group, but implant/screw fracture in the Ci group.
© 2011 Eur J Oral Sci.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21726295     DOI: 10.1111/j.1600-0722.2011.00837.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  10 in total

1.  Stress distribution of multiple implant-supported prostheses: Photoelastic and strain gauge analyses of external hexagon and morse taper connections.

Authors:  Ana-Beatriz-Bueno-Carlini Bittencourt; Erica-de Oliveira-Paiva Rezende; Marcio Campaner; Sandro-Basso Bitencourt; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2022-03-01

Review 2.  Properties of polyetheretheretherketone (PEEK) implant abutments: A systematic review.

Authors:  Romaisa Ghazal-Maghras; Jaime Vilaplana-Vivo; Fabio Camacho-Alonso; Yolanda Martínez-Beneyto
Journal:  J Clin Exp Dent       Date:  2022-04-01

Review 3.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

4.  Reliability evaluation of alumina-blasted/acid-etched versus laser-sintered dental implants.

Authors:  Erika O Almeida; Amilcar C Freitas Júnior; Estevam A Bonfante; Nelson R F A Silva; Paulo G Coelho
Journal:  Lasers Med Sci       Date:  2012-07-28       Impact factor: 3.161

5.  Reliability and failure modes of narrow implant systems.

Authors:  Ronaldo Hirata; Estevam A Bonfante; Rodolfo B Anchieta; Lucas S Machado; Gileade Freitas; Vinicius P Fardin; Nick Tovar; Paulo G Coelho
Journal:  Clin Oral Investig       Date:  2015-11-03       Impact factor: 3.573

6.  The importance of prosthetic planning for implant-supported dentures in esthetic zones - A case report.

Authors:  Gustavo Vargas Da Silva Salomão; Fernando Toledo Santos; Sergio Allegrini Junior
Journal:  Int J Surg Case Rep       Date:  2018-11-27

Review 7.  A Systematic Review of Screw versus Cement-Retained Fixed Implant Supported Reconstructions.

Authors:  Mohamed Tharwat Hamed; Hisham Abdullah Mously; Saeed Khalid Alamoudi; Abou Bakr Hossam Hashem; Ghada Hussein Naguib
Journal:  Clin Cosmet Investig Dent       Date:  2020-01-14

8.  Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study.

Authors:  Sara Hussain Alhammadi; Girvan Burnside; Alexander Milosevic
Journal:  BMC Oral Health       Date:  2021-04-01       Impact factor: 2.757

9.  Mechanical testing of thin-walled zirconia abutments.

Authors:  Luigi Canullo; Paulo G Coelho; Estevam A Bonfante
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

10.  Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.

Authors:  Edmara T P Bergamo; Everardo N S de Araújo-Júnior; Adolfo C O Lopes; Paulo G Coelho; Abbas Zahoui; Ernesto B Benalcázar Jalkh; Estevam A Bonfante
Journal:  Biomed Res Int       Date:  2020-09-07       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.