Literature DB >> 22841669

Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

Michael A DiMaio1, Malaya K Sahoo, Jesse Waggoner, Benjamin A Pinsky.   

Abstract

Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22841669      PMCID: PMC4075941          DOI: 10.1016/j.jviromet.2012.07.023

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  21 in total

1.  Comparison of GeneXpert FluA PCR to direct fluorescent antibody and respiratory viral panel PCR assays for detection of 2009 novel H1N1 influenza virus.

Authors:  Steve Miller; Morvarid Moayeri; Carolyn Wright; Lina Castro; Mark Pandori
Journal:  J Clin Microbiol       Date:  2010-10-20       Impact factor: 5.948

2.  Validation of the Cepheid Xpert Flu A real time RT-PCR detection panel for emergency use authorization.

Authors:  Anthony R Sambol; Peter C Iwen; Maura Pieretti; Samik Basu; Michael H Levi; Kimberly D Gilonske; Kimberly D Moses; Jamie L Marola; Preveen Ramamoorthy
Journal:  J Clin Virol       Date:  2010-06-26       Impact factor: 3.168

3.  Utility of the rapid antigen detection BinaxNOW Influenza A&B test for detection of novel influenza A (H1N1) virus.

Authors:  L Fuenzalida; S Blanco; C Prat; M Vivancos; M J Dominguez; J M Mòdol; C Rodrigo; V Ausina
Journal:  Clin Microbiol Infect       Date:  2010-10       Impact factor: 8.067

4.  A synonymous change in the influenza A virus neuraminidase gene interferes with PCR-based subtyping and oseltamivir resistance mutation detection.

Authors:  Christina Trevino; Selamawit Bihon; Benjamin A Pinsky
Journal:  J Clin Microbiol       Date:  2011-06-22       Impact factor: 5.948

5.  Comparison of Becton Dickinson Directigen EZ Flu A+B test against the CDC real-time PCR assay for detection of 2009 pandemic influenza A/H1N1 virus.

Authors:  Tess Karre; Hugh F Maguire; David Butcher; Amy Graepler; Diane Weed; Michael L Wilson
Journal:  J Clin Microbiol       Date:  2009-11-04       Impact factor: 5.948

6.  Evaluation of a new rapid influenza A diagnostic test for detection of pandemic (H1N1) 2009 and seasonal influenza A virus.

Authors:  Xiao-Dong Cheng; Quan Yuan; Qiao-Hong Yue; Qing-Bing Zheng; Yue-Yun Ma; Bing-Chun Yang; Rong Zhang; Yi-Xin Chen; Ming-Quan Su; Jun Zhang; Ning-Shao Xia; Xiao-Ke Hao
Journal:  J Clin Virol       Date:  2010-11-03       Impact factor: 3.168

Review 7.  Influenza: epidemiology, clinical features, therapy, and prevention.

Authors:  Nina M Clark; Joseph P Lynch
Journal:  Semin Respir Crit Care Med       Date:  2011-08-19       Impact factor: 3.119

8.  Evaluation of three influenza A and B real-time reverse transcription-PCR assays and a new 2009 H1N1 assay for detection of influenza viruses.

Authors:  Suresh B Selvaraju; Rangaraj Selvarangan
Journal:  J Clin Microbiol       Date:  2010-09-15       Impact factor: 5.948

9.  Retrospective and prospective verification of the Cepheid Xpert influenza virus assay.

Authors:  Elena B Popowitch; Elaine Rogers; Melissa B Miller
Journal:  J Clin Microbiol       Date:  2011-07-20       Impact factor: 5.948

10.  Comparison of a laboratory-developed RT-PCR and the CDC RT-PCR protocol with rapid immunodiagnostic testing during the 2009 H1N1 influenza A pandemic.

Authors:  Robert Steven Liao; Olfert Landt; Joseph Thaddeus Hill
Journal:  Diagn Microbiol Infect Dis       Date:  2011-03-09       Impact factor: 2.803

View more
  15 in total

1.  Comparison of the BD Veritor System for Flu A+B with the Alere BinaxNOW influenza A&B card for detection of influenza A and B viruses in respiratory specimens from pediatric patients.

Authors:  Ferdaus Hassan; Ashley Nguyen; Ashley Formanek; James J Bell; Rangaraj Selvarangan
Journal:  J Clin Microbiol       Date:  2014-01-03       Impact factor: 5.948

2.  Improved sensitivity of the novel Xpert flu test for detection of influenza B virus.

Authors:  N Salez; X de Lamballerie; C Zandotti; C Gazin; R N Charrel
Journal:  J Clin Microbiol       Date:  2013-09-25       Impact factor: 5.948

3.  Evaluation of the Xpert Flu rapid PCR assay in high-risk emergency department patients.

Authors:  Andrea F Dugas; Alexandra Valsamakis; Charlotte A Gaydos; Michael Forman; Justin Hardick; Pranav Kidambi; Sharmeen Amin; Alisha Gupta; Richard E Rothman
Journal:  J Clin Microbiol       Date:  2014-09-24       Impact factor: 5.948

4.  Direct Comparison of Alere i and cobas Liat Influenza A and B Tests for Rapid Detection of Influenza Virus Infection.

Authors:  Frederick S Nolte; Lori Gauld; Susan B Barrett
Journal:  J Clin Microbiol       Date:  2016-08-31       Impact factor: 5.948

Review 5.  Respiratory Infections in the U.S. Military: Recent Experience and Control.

Authors:  Jose L Sanchez; Michael J Cooper; Christopher A Myers; James F Cummings; Kelly G Vest; Kevin L Russell; Joyce L Sanchez; Michelle J Hiser; Charlotte A Gaydos
Journal:  Clin Microbiol Rev       Date:  2015-07       Impact factor: 26.132

Review 6.  Advances and challenges in biosensor-based diagnosis of infectious diseases.

Authors:  Mandy L Y Sin; Kathleen E Mach; Pak Kin Wong; Joseph C Liao
Journal:  Expert Rev Mol Diagn       Date:  2014-02-13       Impact factor: 5.225

7.  Performance of the Cobas(®) Influenza A/B Assay for Rapid Pcr-Based Detection of Influenza Compared to Prodesse ProFlu+ and Viral Culture.

Authors:  L Chen; Y Tian; S Chen; O Liesenfeld
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2015-12-04

8.  Simulated Respiratory Secretion for Use in the Development of Influenza Diagnostic Assays.

Authors:  Michael E Bose; Kate C McCaul; Hong Mei; Amy Sasman; Jie He; William Kramp; Roxanne Shively; Ke Yan; Kelly J Henrickson
Journal:  PLoS One       Date:  2016-11-21       Impact factor: 3.240

Review 9.  Sensitivity-Enhancing Strategies in Optical Biosensing.

Authors:  Youngsun Kim; John Gonzales; Yuebing Zheng
Journal:  Small       Date:  2020-12-28       Impact factor: 13.281

10.  Molecular and Culture-Based Bronchoalveolar Lavage Fluid Testing for the Diagnosis of Cytomegalovirus Pneumonitis.

Authors:  Susanna K Tan; Elizabeth B Burgener; Jesse J Waggoner; Kiran Gajurel; Sarah Gonzalez; Sharon F Chen; Benjamin A Pinsky
Journal:  Open Forum Infect Dis       Date:  2016-02-10       Impact factor: 3.835

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.