Literature DB >> 22785337

IVIM-DWI of transplanted kidneys: reduced diffusion and perfusion dependent on cold ischemia time.

S Rheinheimer1, F Schneider, B Stieltjes, C Morath, M Zeier, H U Kauczor, P Hallscheidt.   

Abstract

PURPOSE: To evaluate the effect of cold ischemia time (CIT) of renal allografts on diffusion and perfusion using intravoxel incoherent motion (IVIM) derived parameters.
MATERIAL AND METHODS: A total of 37 patients with renal allografts (CIT: 27 <15 h, 10 ≥15 h) and 30 individuals with healthy kidneys were examined at 1.5 T using a single-shot echo-planar diffusion-weighted pulse sequence with nine b-values ranging from 0 to 800 s/mm(2). ADC, perfusion fraction f, and the diffusion coefficient D were calculated using the IVIM model. Parameters of allografts stratified by CIT were compared with healthy kidney groups using the Mann-Whitney U test for unpaired data. We computed the Spearman correlation coefficient for correlation with creatinine values.
RESULTS: ADC, D, and f of transplanted kidneys were significantly lower than in the healthy controls. The long-CIT group showed significantly lower diffusion parameters compared with the short-CIT group [mean±SD]: ADC: 1.63±0.14 μm(2)/ms, f: 11.90±5.22%, D: 1.55±0.25 μm(2)/ms versus ADC: 1.79±0.13 μm(2)/ms, f: 16.12±3.43%, D: 1.73±0.14 μm(2)/ms, P(ADC), (f), (D)<0.05.
CONCLUSION: Our results suggest that diffusion parameters, especially the ADC, depend on the CIT of the kidney allograft. Potentially, this stands for functional changes in renal allografts. Diffusion-weighted imaging could be used for follow-up examinations. Thus, diffusion parameters may help guide therapy in patients with delayed graft function.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22785337     DOI: 10.1016/j.ejrad.2012.06.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Using intravoxel incoherent motion MR imaging to study the renal pathophysiological process of contrast-induced acute kidney injury in rats: Comparison with conventional DWI and arterial spin labelling.

Authors:  Long Liang; Wen-Bo Chen; Kannie W Y Chan; Yu-Guo Li; Bin Zhang; Chang-Hong Liang; Guan-Shu Liu; Shui-Xing Zhang
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

2.  Assessment of renal allograft function early after transplantation with isotropic resolution diffusion tensor imaging.

Authors:  Wen-jun Fan; Tao Ren; Qiong Li; Pan-li Zuo; Miao-miao Long; Chun-bai Mo; Li-hua Chen; Li-xiang Huang; Wen Shen
Journal:  Eur Radiol       Date:  2015-05-28       Impact factor: 5.315

3.  Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.

Authors:  Jun Lv; Wenjian Huang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-03-28       Impact factor: 3.039

4.  Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI.

Authors:  Octavia Bane; Mathilde Wagner; Jeff L Zhang; Hadrien A Dyvorne; Matthew Orton; Henry Rusinek; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2016-02-08       Impact factor: 4.813

5.  Evaluating early response of cervical cancer under concurrent chemo-radiotherapy by intravoxel incoherent motion MR imaging.

Authors:  Li Zhu; Lijing Zhu; Hua Shi; Huanhuan Wang; Jing Yan; Baorui Liu; Weibo Chen; Jian He; Zhengyang Zhou; Xiaofeng Yang; Tian Liu
Journal:  BMC Cancer       Date:  2016-02-10       Impact factor: 4.430

6.  Monitoring the progression of renal fibrosis by T2-weighted signal intensity and diffusion weighted magnetic resonance imaging in cisplatin induced rat models.

Authors:  Huan-Huan Wu; Hui-Ru Jia; Yi Zhang; Le Liu; Dong-Bo Xu; Hao-Ran Sun
Journal:  Chin Med J (Engl)       Date:  2015-03-05       Impact factor: 2.628

7.  Use of intravoxel incoherent motion imaging to monitor a rat kidney chronic allograft damage model.

Authors:  Qiang Zhang; Zexing Yu; Song Zeng; Lu Liang; Yue Xu; Zijian Zhang; Hao Tang; Wenjiao Jiao; Wenrui Xue; Wei Wang; Xiaodong Zhang; Tao Jiang; Xiaopeng Hu
Journal:  BMC Nephrol       Date:  2019-10-10       Impact factor: 2.388

8.  Evaluation of contrast-induced acute kidney injury using IVIM and DKI MRI in a rat model of diabetic nephropathy.

Authors:  Hongyan Dai; Chun Zhao; Yuxin Xiong; Qian He; Wei Su; Jianbo Li; Ying Yang; Ruyun Lin; Shutian Xiang; Juwei Shao
Journal:  Insights Imaging       Date:  2022-06-29

9.  Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report.

Authors:  Katarzyna Wypych-Klunder; Andrzej Adamowicz; Adam Lemanowicz; Wojciech Szczęsny; Zbigniew Włodarczyk; Zbigniew Serafin
Journal:  Pol J Radiol       Date:  2014-05-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.