Literature DB >> 21715214

Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation.

Ehsan Dehghan1, Ameet K Jain, Mehdi Moradi, Xu Wen, W James Morris, Septimiu E Salcudean, Gabor Fichtinger.   

Abstract

C-arm fluoroscopy images are frequently used for qualitative assessment of prostate brachytherapy. Three-dimensional seed reconstruction from C-arm images is necessary for intraoperative dosimetry and quantitative assessment. Seed reconstruction requires accurately known C-arm poses. We propose to measure the C-arm rotation angles and computationally compensate for inevitable C-arm motion to compute the pose. We compensate the translational motions of a C-arm, such as oscillation, sagging and wheel motion using a three-level optimization algorithm and obviate the need for full pose tracking using external trackers or fiducials. We validated our approach on simulated and 100 clinical data sets from 10 patients and gained on average, a seed matching rate of 98.5%, projection error of 0.33 mm (STD=0.21 mm) and computation time of 19.8s per patient, which must be considered as clinically excellent results. We also show that without motion compensation the reconstruction is likely to fail.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21715214     DOI: 10.1016/j.media.2011.05.017

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  4 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

Authors:  Shahram Amiri; David R Wilson; Bassam A Masri; Carolyn Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-10       Impact factor: 2.924

3.  Segmentation of iodine brachytherapy implants in fluoroscopy.

Authors:  Eric Moult; Gabor Fichtinger; W James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-25       Impact factor: 2.924

4.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.