Literature DB >> 28890754

CT AND MRI FUSION FOR POSTIMPLANT PROSTATE BRACHYTHERAPY EVALUATION.

Ehsan Dehghan1, Yi Le2, Junghoon Lee3, Daniel Y Song3, Gabor Fichtinger3,4, Jerry L Prince3.   

Abstract

Postoperative evaluation of prostate brachytherapy is typically performed using CT, which does not have sufficient soft tissue contrast for accurate anatomy delineation. MR-CT fusion enables more accurate localization of both anatomy and implanted radioactive seeds, and hence, improves the accuracy of postoperative dosimetry. We propose a method for automatic registration of MR and CT images without a need for manual initialization. Our registration method employs a point-to-volume registration scheme during which localized seeds in the CT images, produced by commercial treatment planning systems as part of the standard of care, are rigidly registered to preprocessed MRI images. We tested our algorithm on ten patient data sets and achieved an overall registration error of 1.6 ± 0.8 mm with a running time of less than 20s. With high registration accuracy and computational speed, and no need for manual intervention, our method has the potential to be employed in clinical applications.

Entities:  

Keywords:  CT; MRI; Multi-Modality Registration; Prostate Brachytherapy

Year:  2016        PMID: 28890754      PMCID: PMC5589189          DOI: 10.1109/ISBI.2016.7493345

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  9 in total

1.  Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy.

Authors:  K Kagawa; W R Lee; T E Schultheiss; M A Hunt; A H Shaer; G E Hanks
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-05-01       Impact factor: 7.038

2.  The use of mutual information in registration of CT and MRI datasets post permanent implant.

Authors:  Patrick W McLaughlin; Vrinda Narayana; Marc Kessler; Daniel McShan; Sara Troyer; Lon Marsh; George Hixson; Peter L Roberson
Journal:  Brachytherapy       Date:  2004       Impact factor: 2.362

3.  Use and uncertainties of mutual information for computed tomography/ magnetic resonance (CT/MR) registration post permanent implant of the prostate.

Authors:  Peter L Roberson; P William McLaughlin; Vrinda Narayana; Sara Troyer; George V Hixson; Marc L Kessler
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

4.  Prostate seed implant quality assessment using MR and CT image fusion.

Authors:  R J Amdur; D Gladstone; K A Leopold; R D Harris
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-01-01       Impact factor: 7.038

5.  AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: report of Task Group 137.

Authors:  Ravinder Nath; William S Bice; Wayne M Butler; Zhe Chen; Ali S Meigooni; Vrinda Narayana; Mark J Rivard; Yan Yu
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

7.  Sequential evaluation of prostate edema after permanent seed prostate brachytherapy using CT-MRI fusion.

Authors:  Daniel Taussky; Lyn Austen; Ants Toi; Ivan Yeung; Theresa Williams; Shannon Pearson; Michael McLean; Gregory Pond; Juanita Crook
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

8.  The effect of interobserver differences in post-implant prostate CT image interpretation on dosimetric parameters.

Authors:  Ben H Han; Kent Wallner; Gregory Merrick; Kas Badiozamani; Wayne Butler
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

9.  Post-implant computed tomography-magnetic resonance prostate image registration using feature line parallelization and normalized mutual information.

Authors:  Sandra Vidakovic; Hans S Jans; Abe Alexander; Ron S Sloboda
Journal:  J Appl Clin Med Phys       Date:  2006-07-05       Impact factor: 2.102

  9 in total
  2 in total

1.  3D-Image-Guided Multi-Catheter Interstitial Brachytherapy for Bulky and High-Risk Stage IIB-IVB Cervical Cancer.

Authors:  Tetsuya Kokabu; Koji Masui; Yosuke Tarumi; Naoki Noguchi; Kohei Aoyama; Hisashi Kataoka; Hiroshi Matsushima; Kaori Yoriki; Daisuke Shimizu; Hideya Yamazaki; Kei Yamada; Taisuke Mori
Journal:  Cancers (Basel)       Date:  2022-02-28       Impact factor: 6.639

2.  Value of CT-MRI fusion in iodine-125 brachytherapy for high-grade glioma.

Authors:  Yang Gao; Yan Han; Guo Nan; Man Hu; Xiaobin Zhou; Xiaokun Hu
Journal:  Oncotarget       Date:  2017-12-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.