Literature DB >> 22760825

Reduced blood flow artifact in intraplaque hemorrhage imaging using CineMPRAGE.

Jason Mendes1, Dennis L Parker, Seong-Eun Kim, Gerald S Treiman.   

Abstract

Magnetization prepared rapid acquisition gradient echo (3D MPRAGE) has been shown to be a sensitive method to image carotid intraplaque hemorrhage. As the MPRAGE sequence used to identify potential intraplaque hemorrhage does not utilize cardiac gating, it is difficult to optimize the inversion times due to the dynamic nature of flowing blood. As a result, a best fit inversion time is often determined experimentally and then used for in vivo clinical examination. This results in compromised blood suppression and occasional hemorrhage mimicking flow artifacts. We demonstrate that a retrospective cardiac correlated reconstruction can be applied to the conventional MPRAGE sequence (CineMPRAGE) to more accurately identify blood signal. This CineMPRAGE reconstruction uses the data from a standard nongated MPRAGE sequence to generate a full sequence of cardiac correlated images throughout the cardiac cycle and, therefore, provides a dynamic view of the carotid artery and a better ability to discern blood signal from potential intraplaque hemorrhage. In our preliminary study of 35 patients, signal from potential hemorrhage was constant over the cardiac cycle, whereas any signal from blood flow artifact was observed as an oscillating signal over the cardiac cycle.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22760825      PMCID: PMC3465506          DOI: 10.1002/mrm.24354

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence.

Authors:  Jinnan Wang; Vasily L Yarnykh; Thomas Hatsukami; Baocheng Chu; Niranjan Balu; Chun Yuan
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

2.  Carotid intraplaque hemorrhage imaging at 3.0-T MR imaging: comparison of the diagnostic performance of three T1-weighted sequences.

Authors:  Hideki Ota; Vasily L Yarnykh; Marina S Ferguson; Hunter R Underhill; J Kevin Demarco; David C Zhu; Minako Oikawa; Li Dong; Xihai Zhao; Alonso Collar; Thomas S Hatsukami; Chun Yuan
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

3.  An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage imaging at 3.0 T.

Authors:  David C Zhu; Marina S Ferguson; J Kevin DeMarco
Journal:  Magn Reson Imaging       Date:  2008-06-25       Impact factor: 2.546

4.  In vivo three-dimensional blood velocity profile shapes in the human common, internal, and external carotid arteries.

Authors:  Alexey V Kamenskiy; Yuris A Dzenis; Jason N Mactaggart; Anastasia S Desyatova; Iraklis I Pipinos
Journal:  J Vasc Surg       Date:  2011-05-28       Impact factor: 4.268

5.  Improved carotid intraplaque hemorrhage imaging using a slab-selective phase-sensitive inversion-recovery (SPI) sequence.

Authors:  Jinnan Wang; Marina S Ferguson; Niranjan Balu; Chun Yuan; Thomas S Hatsukami; Peter Börnert
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

6.  An optimized 3D spoiled gradient recalled echo pulse sequence for hemorrhage assessment using inversion recovery and multiple echoes (3D SHINE) for carotid plaque imaging.

Authors:  David C Zhu; Anthony T Vu; Hideki Ota; J Kevin DeMarco
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

7.  Association between signal hyperintensity on T1-weighted MR imaging of carotid plaques and ipsilateral ischemic events.

Authors:  N Yamada; M Higashi; R Otsubo; T Sakuma; N Oyama; R Tanaka; K Iihara; H Naritomi; K Minematsu; H Naito
Journal:  AJNR Am J Neuroradiol       Date:  2007-02       Impact factor: 3.825

8.  In vivo 3D high-spatial-resolution MR imaging of intraplaque hemorrhage.

Authors:  Richard Bitar; Alan R Moody; General Leung; Sean Symons; Susan Crisp; Jagdish Butany; Corwyn Rowsell; Alexander Kiss; Andrew Nelson; Robert Maggisano
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

9.  Moderate carotid artery stenosis: MR imaging-depicted intraplaque hemorrhage predicts risk of cerebrovascular ischemic events in asymptomatic men.

Authors:  Navneet Singh; Alan R Moody; David J Gladstone; General Leung; Radhakrishnan Ravikumar; James Zhan; Robert Maggisano
Journal:  Radiology       Date:  2009-06-09       Impact factor: 11.105

10.  Intraplaque hemorrhage is associated with higher structural stresses in human atherosclerotic plaques: an in vivo MRI-based 3D fluid-structure interaction study.

Authors:  Xueying Huang; Zhongzhao Teng; Gador Canton; Marina Ferguson; Chun Yuan; Dalin Tang
Journal:  Biomed Eng Online       Date:  2010-12-31       Impact factor: 2.819

View more
  7 in total

1.  Age-Specific Sex Differences in Magnetic Resonance Imaging-Depicted Carotid Intraplaque Hemorrhage.

Authors:  Navneet Singh; Alan R Moody; Bowen Zhang; Isabella Kaminski; Kush Kapur; Stephanie Chiu; Pascal N Tyrrell
Journal:  Stroke       Date:  2017-07-13       Impact factor: 7.914

2.  Carotid MRI Detection of Intraplaque Hemorrhage at 3T and 1.5T.

Authors:  J Scott McNally; Hyo-Chun Yoon; Seong-Eun Kim; Krishna K Narra; Michael S McLaughlin; Dennis L Parker; Gerald S Treiman
Journal:  J Neuroimaging       Date:  2014-07-15       Impact factor: 2.486

Review 3.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

4.  Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique.

Authors:  Seong-Eun Kim; John A Roberts; Laura B Eisenmenger; Booth W Aldred; Osama Jamil; Bradley D Bolster; Xiaoming Bi; Dennis L Parker; Gerald S Treiman; J Scott McNally
Journal:  J Magn Reson Imaging       Date:  2016-07-07       Impact factor: 4.813

5.  Semi-automatic carotid intraplaque hemorrhage detection and quantification on Magnetization-Prepared Rapid Acquisition Gradient-Echo (MP-RAGE) with optimized threshold selection.

Authors:  Jin Liu; Niranjan Balu; Daniel S Hippe; Marina S Ferguson; Vanesa Martinez-Malo; J Kevin DeMarco; David C Zhu; Hideki Ota; Jie Sun; Dongxiang Xu; William S Kerwin; Thomas S Hatsukami; Chun Yuan
Journal:  J Cardiovasc Magn Reson       Date:  2016-07-16       Impact factor: 5.364

Review 6.  Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage.

Authors:  J Scott McNally; Seong-Eun Kim; Jason Mendes; J Rock Hadley; Akihiko Sakata; Adam H De Havenon; Gerald S Treiman; Dennis L Parker
Journal:  Magn Reson Insights       Date:  2017-03-07

7.  Quantification of Carotid Intraplaque Hemorrhage: Comparison between Manual Segmentation and Semi-Automatic Segmentation on Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequences.

Authors:  Young Ju Song; Hyo Sung Kwak; Gyung Ho Chung; Seongil Jo
Journal:  Diagnostics (Basel)       Date:  2019-11-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.