Literature DB >> 17969103

Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence.

Jinnan Wang1, Vasily L Yarnykh, Thomas Hatsukami, Baocheng Chu, Niranjan Balu, Chun Yuan.   

Abstract

In this study, a turbo spin-echo (TSE) based motion-sensitized driven-equilibrium (MSDE) sequence was used as an alternative black-blood (BB) carotid MRI imaging scheme. The MSDE sequence was first optimized for more efficient residual blood signal suppression in the carotid bulb of healthy volunteers. Effective contrast-to-noise ratio (CNR(eff)) and residual signal-to-noise ratio (SNR) in the lumen measured from MSDE images were then compared to those measured from inflow saturation (IS) and double inversion-recovery (DIR) images. Statistically significant higher CNR(eff) and lower lumen SNR were obtained from MSDE images. To assess MSDE sequence in a clinical carotid protocol, 42 locations from six subjects with 50% to 79% carotid stenosis by duplex ultrasound were scanned with both MSDE and multislice DIR. The comparison showed that MSDE images present significantly higher CNR and lower lumen SNR compared to corresponding multislice DIR images. The vessel wall area and mean wall thickness measurements in MSDE images were slightly but significantly lower than those obtained with other blood suppression techniques. In conclusion, in vivo comparisons demonstrated that MSDE sequence can achieve better blood suppression and provide a more accurate depiction of the lumen boundaries by eliminating plaque mimicking artifacts in carotid artery (CA) imaging. Copyright 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17969103     DOI: 10.1002/mrm.21385

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  75 in total

1.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Fast plaque burden assessment of the femoral artery using 3D black-blood MRI and automated segmentation.

Authors:  Bernard Chiu; Jie Sun; Xihai Zhao; Jinnan Wang; Niranjan Balu; Jiachang Chi; Jianrong Xu; Chun Yuan; William S Kerwin
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

4.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

5.  Evaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.

Authors:  A Hiwatashi; T Yoshiura; O Togao; K Yamashita; K Kikuchi; K Kobayashi; M Ohga; S Sonoda; H Honda; M Obara
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

6.  3D turbo field echo with diffusion-sensitized driven-equilibrium preparation technique (DSDE-TFE) versus echo planar imaging in evaluation of diffusivity of retinoblastoma.

Authors:  Akio Hiwatashi; Osamu Togao; Koji Yamashita; Kazufumi Kikuchi; Hiroshi Yoshikawa; Makoto Obara; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-09-16       Impact factor: 3.039

7.  Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

Authors:  Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad
Journal:  Magn Reson Med       Date:  2016-09-16       Impact factor: 4.668

8.  Dual stack black blood carotid artery CMR at 3T: application to wall thickness visualization.

Authors:  Axel Bornstedt; Mathias Burgmaier; Vinzenz Hombach; Nikolaus Marx; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-10       Impact factor: 5.364

Review 9.  Magnetic [corrected] resonance imaging [corrected] features of the disruption-prone and the disrupted carotid plaque.

Authors:  Baocheng Chu; Marina S Ferguson; Huijun Chen; Daniel S Hippe; William S Kerwin; Gador Canton; Chun Yuan; Thomas S Hatsukami
Journal:  JACC Cardiovasc Imaging       Date:  2009-07

10.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.