Literature DB >> 22754417

A pre-clinical test platform for the functional evaluation of scaffolds for musculoskeletal defects: the meniscus.

Suzanne A Maher1, Scott A Rodeo, Hollis G Potter, Lawrence J Bonassar, Timothy M Wright, Russell F Warren.   

Abstract

In an attempt to delay the progression of osteoarthritis from an index injury, early intervention via repair of injured musculoskeletal soft tissue has been advocated. Despite the development of a number of scaffolds intended to treat soft tissue defects, information about their functional performance is lacking. The goal of this study was to consolidate a suite of in vitro and in vivo models into a pre-clinical test platform to assess the functional performance of meniscal repair scaffolds. Our objective was to assess the ability of a scaffold (Actifit™; Orteq, UK) to carry load without detrimentally abrading against articular cartilage. Three test modules were used to assess the functional performance of meniscal repair scaffolds. The first module tested the ability of the scaffold to carry load in an in vitro model designed to measure the change in normal contact stress magnitude on the tibial plateau of cadaveric knees after scaffold implantation. The second module assessed the in vitro frictional coefficient of the scaffold against cartilage to assess the likelihood that the scaffold would destructively abrade against articular cartilage in vivo. The third module consisted of an assessment of functional performance in vivo by measuring the structure and composition of articular cartilage across the tibial plateau 12 months after scaffold implantation in an ovine model. In vitro, the scaffold improved contact mechanics relative to a partly meniscectomized knee suggesting that, in vivo, less damage would be seen in the scaffold implanted knees vs. partly meniscectomized knees. However, there was no significant difference in the condition of articular cartilage between the two groups. Moreover, in spite of the high coefficient of friction between the scaffold and articular cartilage, there was no significant damage in the articular cartilage underneath the scaffold. The discrepancy between the in vitro and in vivo models was likely influenced by the abundant tissue generated within the scaffold and the unexpected tissue that regenerated within the site of the partial meniscectomy. We are currently augmenting our suite of tests so that we can pre-clinically evaluate the functional performance at time zero and as a function of time after implantation.

Entities:  

Keywords:  cartilage; knee; meniscus; scaffold

Year:  2011        PMID: 22754417      PMCID: PMC3145852          DOI: 10.1007/s11420-010-9188-6

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  35 in total

1.  Second generation of meniscus transplantation: in-vivo study with tissue engineered meniscus replacement.

Authors:  V Martinek; P Ueblacker; K Bräun; S Nitschke; R Mannhardt; K Specht; B Gansbacher; A B Imhoff
Journal:  Arch Orthop Trauma Surg       Date:  2005-10-08       Impact factor: 3.067

2.  A tissue engineering approach to meniscus regeneration in a sheep model.

Authors:  C Chiari; U Koller; R Dorotka; C Eder; R Plasenzotti; S Lang; L Ambrosio; E Tognana; E Kon; D Salter; S Nehrer
Journal:  Osteoarthritis Cartilage       Date:  2006-05-30       Impact factor: 6.576

3.  Tissue engineering for total meniscal substitution: animal study in sheep model.

Authors:  Elizaveta Kon; Catharina Chiari; Maurilio Marcacci; Marco Delcogliano; Donald M Salter; Ivan Martin; Luigi Ambrosio; Milena Fini; Matilde Tschon; Enrico Tognana; Roberto Plasenzotti; Stefan Nehrer
Journal:  Tissue Eng Part A       Date:  2008-06       Impact factor: 3.845

4.  How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

Authors:  Tammy L Haut Donahue; M L Hull; Mark M Rashid; Christopher R Jacobs
Journal:  J Biomech       Date:  2003-01       Impact factor: 2.712

5.  Evaluation of a porous polyurethane scaffold in a partial meniscal defect ovine model.

Authors:  Suzanne A Maher; Scott A Rodeo; Stephen B Doty; Robert Brophy; Hollis Potter; Li-Foong Foo; Lauren Rosenblatt; Xiang-Hua Deng; Anthony S Turner; Timothy M Wright; Russell F Warren
Journal:  Arthroscopy       Date:  2010-09-19       Impact factor: 4.772

6.  Cemented total knee arthroplasty using a modern prosthesis in young patients with osteoarthritis.

Authors:  Gavan P Duffy; Amy R Crowder; Robert R Trousdale; Daniel J Berry
Journal:  J Arthroplasty       Date:  2007-09       Impact factor: 4.757

7.  Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci.

Authors:  H Kurosawa; T Fukubayashi; H Nakajima
Journal:  Clin Orthop Relat Res       Date:  1980-06       Impact factor: 4.176

8.  Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants.

Authors:  Roland Becker; Dieter Wirz; Cornelius Wolf; Beat Göpfert; Wolfgang Nebelung; Niklaus Friederich
Journal:  Arch Orthop Trauma Surg       Date:  2004-09-07       Impact factor: 3.067

9.  Hip resurfacing increases bone strains associated with short-term femoral neck fracture.

Authors:  Jason P Long; Thomas J Santner; Donald L Bartel
Journal:  J Orthop Res       Date:  2009-10       Impact factor: 3.494

10.  Assessment of a bovine co-culture, scaffold-free method for growing meniscus-shaped constructs.

Authors:  Adam C Aufderheide; Kyriacos A Athanasiou
Journal:  Tissue Eng       Date:  2007-09
View more
  10 in total

Review 1.  Synthetic meniscus replacement: a review.

Authors:  Anne Christiane Theodora Vrancken; Pieter Buma; Tony George van Tienen
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

Review 2.  * The Ovine Model for Meniscus Tissue Engineering: Considerations of Anatomy, Function, Implantation, and Evaluation.

Authors:  Andrzej Brzezinski; Salim A Ghodbane; Jay M Patel; Barbara A Perry; Charles J Gatt; Michael G Dunn
Journal:  Tissue Eng Part C Methods       Date:  2017-09-29       Impact factor: 3.056

3.  A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

Authors:  Feini Qu; Brendan D Stoeckl; Peter M Gebhard; Todd J Hullfish; Josh R Baxter; Robert L Mauck
Journal:  Ann Biomed Eng       Date:  2018-08-06       Impact factor: 3.934

4.  T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee.

Authors:  Rachel K Surowiec; Erin P Lucas; Eric K Fitzcharles; Benjamin M Petre; Grant J Dornan; J Erik Giphart; Robert F LaPrade; Charles P Ho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-24       Impact factor: 4.342

5.  In Vitro Testing of Scaffolds for Mesenchymal Stem Cell-Based Meniscus Tissue Engineering-Introducing a New Biocompatibility Scoring System.

Authors:  Felix P Achatz; Richard Kujat; Christian G Pfeifer; Matthias Koch; Michael Nerlich; Peter Angele; Johannes Zellner
Journal:  Materials (Basel)       Date:  2016-04-07       Impact factor: 3.623

6.  Tissue Engineering of Large Full-Size Meniscus Defects by a Polyurethane Scaffold: Accelerated Regeneration by Mesenchymal Stromal Cells.

Authors:  Matthias Koch; Felix P Achatz; Siegmund Lang; Christian G Pfeifer; Girish Pattappa; Richard Kujat; Michael Nerlich; Peter Angele; Johannes Zellner
Journal:  Stem Cells Int       Date:  2018-05-07       Impact factor: 5.443

7.  Articular cartilage and meniscus reveal higher friction in swing phase than in stance phase under dynamic gait conditions.

Authors:  Daniela Warnecke; Maxi Meßemer; Luisa de Roy; Svenja Stein; Cristina Gentilini; Robert Walker; Nick Skaer; Anita Ignatius; Lutz Dürselen
Journal:  Sci Rep       Date:  2019-04-08       Impact factor: 4.379

8.  Synthetic PVA Osteochondral Implants for the Knee Joint: Mechanical Characteristics During Simulated Gait.

Authors:  Tony Chen; Caroline Brial; Moira McCarthy; Russell F Warren; Suzanne A Maher
Journal:  Am J Sports Med       Date:  2021-08-04       Impact factor: 7.010

9.  In vivo performance of a novel silk fibroin scaffold for partial meniscal replacement in a sheep model.

Authors:  Katharina Gruchenberg; Anita Ignatius; Benedikt Friemert; Falk von Lübken; Nick Skaer; Kris Gellynck; Oliver Kessler; Lutz Dürselen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-26       Impact factor: 4.342

10.  Augmented repair of radial meniscus tear with biomimetic electrospun scaffold: an in vitro mechanical analysis.

Authors:  Benjamin B Rothrauff; Piya-On Numpaisal; Brian B Lauro; Peter G Alexander; Richard E Debski; Volker Musahl; Rocky S Tuan
Journal:  J Exp Orthop       Date:  2016-09-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.