Literature DB >> 12485635

How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

Tammy L Haut Donahue1, M L Hull, Mark M Rashid, Christopher R Jacobs.   

Abstract

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage. Copyright 2002 Elsevier Science Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12485635     DOI: 10.1016/s0021-9290(02)00305-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  57 in total

1.  [Anterior meniscotibial ligaments. Forces under various load conditions].

Authors:  A M Seitz; R Kasisari; A Lubomierski; A Ignatius; L Dürselen
Journal:  Orthopade       Date:  2012-04       Impact factor: 1.087

2.  Forces acting on the anterior meniscotibial ligaments.

Authors:  Andreas Seitz; Riza Kasisari; Lutz Claes; Anita Ignatius; Lutz Dürselen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-18       Impact factor: 4.342

Review 3.  Multiscale mechanics of articular cartilage: potentials and challenges of coupling musculoskeletal, joint, and microscale computational models.

Authors:  J P Halloran; S Sibole; C C van Donkelaar; M C van Turnhout; C W J Oomens; J A Weiss; F Guilak; A Erdemir
Journal:  Ann Biomed Eng       Date:  2012-05-31       Impact factor: 3.934

4.  The influence of pre-tensioning of meniscal transplants on the tibiofemoral contact area.

Authors:  G von Lewinski; C Hurschler; C Allmann; C J Wirth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-11-22       Impact factor: 4.342

5.  Physical validation of a patient-specific contact finite element model of the ankle.

Authors:  Donald D Anderson; Jane K Goldsworthy; Wendy Li; M James Rudert; Yuki Tochigi; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-12       Impact factor: 2.712

Review 6.  The transverse genicular ligament: anatomical study and review of the literature.

Authors:  R Shane Tubbs; Jennifer Michelson; Marios Loukas; Mohammadali M Shoja; Mohammad R Ardalan; E George Salter; W Jerry Oakes
Journal:  Surg Radiol Anat       Date:  2007-11-08       Impact factor: 1.246

Review 7.  Verification, validation and sensitivity studies in computational biomechanics.

Authors:  Andrew E Anderson; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-06       Impact factor: 1.763

8.  Quantification of meniscal volume by segmentation of 3T magnetic resonance images.

Authors:  Megan E Bowers; Glenn A Tung; Braden C Fleming; Joseph J Crisco; Jesus Rey
Journal:  J Biomech       Date:  2007-03-27       Impact factor: 2.712

9.  From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments.

Authors:  Adam C Abraham; Tammy L Haut Donahue
Journal:  Acta Biomater       Date:  2013-02-04       Impact factor: 8.947

10.  Bone Plug Versus Suture-Only Fixation of Meniscal Grafts: Effect on Joint Contact Mechanics During Simulated Gait.

Authors:  Hongsheng Wang; Albert O Gee; Ian D Hutchinson; Kirsten Stoner; Russell F Warren; Tony O Chen; Suzanne A Maher
Journal:  Am J Sports Med       Date:  2014-04-28       Impact factor: 6.202

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.