Literature DB >> 19338031

Hip resurfacing increases bone strains associated with short-term femoral neck fracture.

Jason P Long1, Thomas J Santner, Donald L Bartel.   

Abstract

Short-term femoral neck fracture is a primary complication associated with contemporary hip resurfacing. Some fractures are associated with neck notching, while others occur in the absence of notching. These unexplained fractures may be due to large magnitude strains near the implant rim, which could cause bone damage accumulation and eventual neck fracture. We used statistically augmented finite element analysis to identify design and environmental variables that increase bone strains near the implant rim after resurfacing, and lead to strain magnitudes sufficient for rapid damage accumulation. After resurfacing, the compressive strains in the inferior, peripheral neck increased by approximately 25%, particularly when the implant shell was bonded. While the tensile strains in the peripheral neck were low in magnitude in the immediate postoperative models, they increased substantially following compressive damage accumulation. Low bone modulus, within the range of normal bone, and high head load contributed the most to large magnitude strains. Therefore, in some cases, hip resurfacing may cause a region of compressive bone damage to develop rapidly, which in turn leads to large tensile strains and potential neck fracture. Our study suggests that indications for surgery should account for bone material quality, and that rehabilitation protocols should avoid high-load activities. (c) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19338031     DOI: 10.1002/jor.20884

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  3 in total

1.  Improved mechanical long-term reliability of hip resurfacing prostheses by using silicon nitride.

Authors:  Wen Zhang; M Titze; B Cappi; D C Wirtz; R Telle; H Fischer
Journal:  J Mater Sci Mater Med       Date:  2010-08-20       Impact factor: 3.896

2.  A pre-clinical test platform for the functional evaluation of scaffolds for musculoskeletal defects: the meniscus.

Authors:  Suzanne A Maher; Scott A Rodeo; Hollis G Potter; Lawrence J Bonassar; Timothy M Wright; Russell F Warren
Journal:  HSS J       Date:  2011-01-08

3.  Failed internal fixation.

Authors:  Praveen Mereddy
Journal:  Acta Orthop       Date:  2011-02-01       Impact factor: 3.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.