Literature DB >> 22752522

MR T1ρ as an imaging biomarker for monitoring liver injury progression and regression: an experimental study in rats with carbon tetrachloride intoxication.

Feng Zhao1, Yi-Xiang J Wang, Jing Yuan, Min Deng, Hing Lok Wong, Eagle S H Chu, Minnie Y Y Go, Gao-Jun Teng, Anil T Ahuja, Jun Yu.   

Abstract

OBJECTIVES: Recently it was shown that the magnetic resonance imaging (MRI) T1ρ value increased with the severity of liver fibrosis in rats with bile duct ligation. Using a rat carbon tetrachloride (CCl(4)) liver injury model, this study further investigated the merit of T1ρ relaxation for liver fibrosis evaluation.
METHODS: Male Sprague-Dawley rats received intraperitoneal injection of 2 ml/kg CCl(4) twice weekly for up to 6 weeks. Then CCl(4) was withdrawn and the animals were allowed to recover. Liver T1ρ MRI and conventional T2-weighted images were acquired. Animals underwent MRI at baseline and at 2 days, 2 weeks, 4 weeks and 6 weeks post CCl(4) injection, and they were also examined at 1 week and 4 weeks post CCl(4) withdrawal. Liver histology was also sampled at these time points.
RESULTS: Liver T1ρ values increased slightly, though significantly, on day 2, and then increased further and were highest at week 6 post CCl(4) insults. The relative liver signal intensity change on T2-weighted images followed a different time course compared with that of T1ρ. Liver T1ρ values decreased upon the withdrawal of the CCl(4) insult. Histology confirmed the animals had typical CCl(4) liver injury and fibrosis progression and regression processes.
CONCLUSIONS: MR T1ρ imaging can monitor CCl(4)-induced liver injury and fibrosis. KEY POINTS: • MR T1ρ is a valuable imaging biomarker for liver injury/fibrosis. • Liver T1ρ was only mildly affected by oedema and acute inflammation. • Liver MR T1ρ decreased when liver fibrosis and injury regressed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22752522     DOI: 10.1007/s00330-012-2419-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  46 in total

1.  Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence.

Authors:  M Deng; F Zhao; J Yuan; A T Ahuja; Y-X J Wang
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

Review 2.  Assessment of fibrosis in chronic liver diseases.

Authors:  Kun Zhou; Lun Gen Lu
Journal:  J Dig Dis       Date:  2009-02       Impact factor: 2.325

Review 3.  Biomedical imaging in the safety evaluation of new drugs.

Authors:  Yi-Xiang J Wang; Sen-Xiang Yan
Journal:  Lab Anim       Date:  2008-09-09       Impact factor: 2.471

4.  Liver fibrosis: noninvasive diagnosis with double contrast material-enhanced MR imaging.

Authors:  Diego A Aguirre; Cynthia A Behling; Elliot Alpert; Tarek I Hassanein; Claude B Sirlin
Journal:  Radiology       Date:  2006-05       Impact factor: 11.105

Review 5.  Experimental models of hepatic fibrosis: a review.

Authors:  H Tsukamoto; M Matsuoka; S W French
Journal:  Semin Liver Dis       Date:  1990-02       Impact factor: 6.115

6.  Regression of human cirrhosis. Morphologic features and the genesis of incomplete septal cirrhosis.

Authors:  I R Wanless; E Nakashima; M Sherman
Journal:  Arch Pathol Lab Med       Date:  2000-11       Impact factor: 5.534

7.  Spin locking for magnetic resonance imaging with application to human breast.

Authors:  G E Santyr; R M Henkelman; M J Bronskill
Journal:  Magn Reson Med       Date:  1989-10       Impact factor: 4.668

8.  Regression of liver fibrosis after biliary drainage in patients with chronic pancreatitis and stenosis of the common bile duct.

Authors:  P Hammel; A Couvelard; D O'Toole; A Ratouis; A Sauvanet; J F Fléjou; C Degott; J Belghiti; P Bernades; D Valla; P Ruszniewski; P Lévy
Journal:  N Engl J Med       Date:  2001-02-08       Impact factor: 91.245

9.  Protein dynamics studied by rotating frame 15N spin relaxation times.

Authors:  T Szyperski; P Luginbühl; G Otting; P Güntert; K Wüthrich
Journal:  J Biomol NMR       Date:  1993-03       Impact factor: 2.835

10.  Mechanisms of spontaneous resolution of rat liver fibrosis. Hepatic stellate cell apoptosis and reduced hepatic expression of metalloproteinase inhibitors.

Authors:  J P Iredale; R C Benyon; J Pickering; M McCullen; M Northrop; S Pawley; C Hovell; M J Arthur
Journal:  J Clin Invest       Date:  1998-08-01       Impact factor: 14.808

View more
  25 in total

1.  Further exploration of MRI techniques for liver T1rho quantification.

Authors:  Feng Zhao; Jing Yuan; Min Deng; Pu-Xuan Lu; Anil T Ahuja; Yi-Xiang J Wang
Journal:  Quant Imaging Med Surg       Date:  2013-12

Review 2.  Advances in functional and molecular MRI technologies in chronic liver diseases.

Authors:  Iris Y Zhou; Onofrio A Catalano; Peter Caravan
Journal:  J Hepatol       Date:  2020-06-22       Impact factor: 25.083

3.  Accelerated T1rho relaxation quantification in intervertebral disc using limited spin-lock times.

Authors:  Yi-Xiang J Wang; Feng Zhao; Jing Yuan; Greta Sp Mok; Anil T Ahuja; James F Griffith
Journal:  Quant Imaging Med Surg       Date:  2013-02

4.  Age related reduction of T1rho and T2 magnetic resonance relaxation times of lumbar intervertebral disc.

Authors:  Yi-Xiang J Wang; James F Griffith; Jason C S Leung; Jing Yuan
Journal:  Quant Imaging Med Surg       Date:  2014-08

5.  Evaluation of liver fibrosis with T1ρ MR imaging.

Authors:  Yi-Xiang J Wang; Jing Yuan
Journal:  Quant Imaging Med Surg       Date:  2014-06

6.  Chemical Exchange Saturation Transfer (CEST) MR Technique for Liver Imaging at 3.0 Tesla: an Evaluation of Different Offset Number and an After-Meal and Over-Night-Fast Comparison.

Authors:  Min Deng; Shu-Zhong Chen; Jing Yuan; Queenie Chan; Jinyuan Zhou; Yì-Xiáng J Wáng
Journal:  Mol Imaging Biol       Date:  2016-04       Impact factor: 3.488

7.  How liver pathologies contribute to T1rho contrast require more careful studies.

Authors:  Yì Xiáng J Wáng; Weitian Chen; Min Deng
Journal:  Quant Imaging Med Surg       Date:  2017-10

8.  Black blood T1rho MR imaging may diagnose early stage liver fibrosis: a proof-of-principle study with rat biliary duct ligation model.

Authors:  Chi-Man Koon; Xin Zhang; Weitian Chen; Eagle Siu Hong Chu; Clara Bik San Lau; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-08

Review 9.  T₁ρ MRI of human musculoskeletal system.

Authors:  Ligong Wang; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

10.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.