Literature DB >> 22752320

Dose distribution for dental cone beam CT and its implication for defining a dose index.

R Pauwels1, C Theodorakou, A Walker, H Bosmans, R Jacobs, K Horner, R Bogaerts.   

Abstract

OBJECTIVES: To characterize the dose distribution for a range of cone beam CT (CBCT) units, investigating different field of view sizes, central and off-axis geometries, full or partial rotations of the X-ray tube and different clinically applied beam qualities. The implications of the dose distributions on the definition and practicality of a CBCT dose index were assessed.
METHODS: Dose measurements on CBCT devices were performed by scanning cylindrical head-size water and polymethyl methacrylate phantoms, using thermoluminescent dosemeters, a small-volume ion chamber and radiochromic films.
RESULTS: It was found that the dose distribution can be asymmetrical for dental CBCT exposures throughout a homogeneous phantom, owing to an asymmetrical positioning of the isocentre and/or partial rotation of the X-ray source. Furthermore, the scatter tail along the z-axis was found to have a distinct shape, generally resulting in a strong drop (90%) in absorbed dose outside the primary beam.
CONCLUSIONS: There is no optimal dose index available owing to the complicated exposure geometry of CBCT and the practical aspects of quality control measurements. Practical validation of different possible dose indices is needed, as well as the definition of conversion factors to patient dose.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22752320      PMCID: PMC3608380          DOI: 10.1259/dmfr/20920453

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  23 in total

1.  Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient.

Authors:  K N Wise; M Sandborg; J Persliden; G A Carlsson
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

2.  A new look at CT dose measurement: beyond CTDI.

Authors:  Robert L Dixon
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

3.  Cone beam CT dosimetry: a unified and self-consistent approach including all scan modalities--with or without phantom motion.

Authors:  Robert L Dixon; John M Boone
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

4.  Effective dose range for dental cone beam computed tomography scanners.

Authors:  Ruben Pauwels; Jilke Beinsberger; Bruno Collaert; Chrysoula Theodorakou; Jessica Rogers; Anne Walker; Lesley Cockmartin; Hilde Bosmans; Reinhilde Jacobs; Ria Bogaerts; Keith Horner
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

5.  ALARA still applies.

Authors:  Allan G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-10

6.  Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.

Authors:  O Rampado; E Garelli; S Deagostini; R Ropolo
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

7.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

8.  Novel methods of measuring single scan dose profiles and cumulative dose in CT.

Authors:  K D Nakonechny; B G Fallone; S Rathee
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

9.  Measurement of radiation dose in dental radiology.

Authors:  Ebba Helmrot; Gudrun Alm Carlsson
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

10.  Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry.

Authors:  Shinichiro Mori; Masahiro Endo; Kanae Nishizawa; Takanori Tsunoo; Takahiko Aoyama; Hideaki Fujiwara; Kenya Murase
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

View more
  15 in total

1.  Movement characteristics in young patients and the impact on CBCT image quality.

Authors:  Rubens Spin-Neto; Louise H Matzen; Lars Schropp; Erik Gotfredsen; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2016-02-26       Impact factor: 2.419

2.  Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use.

Authors:  Ruben Pauwels; Keith Horner; Jenia Vassileva; Madan M Rehani
Journal:  Dentomaxillofac Radiol       Date:  2019-07-09       Impact factor: 2.419

3.  Image quality optimization using a narrow vertical detector dental cone-beam CT.

Authors:  Danieli Moura Brasil; Ruben Pauwels; Wim Coucke; Francisco Haiter-Neto; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2019-01-31       Impact factor: 2.419

4.  Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography--an in-vitro investigation.

Authors:  Elisabeth Hofmann; Matthias Schmid; Martin Sedlmair; Rosemarie Banckwitz; Ursula Hirschfelder; Michael Lell
Journal:  Clin Oral Investig       Date:  2013-03-05       Impact factor: 3.573

5.  Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

Authors:  R Pauwels; G Zhang; C Theodorakou; A Walker; H Bosmans; R Jacobs; R Bogaerts; K Horner
Journal:  Br J Radiol       Date:  2014-10       Impact factor: 3.039

6.  Detection of patient movement during CBCT examination using video observation compared with an accelerometer-gyroscope tracking system.

Authors:  Rubens Spin-Neto; Louise H Matzen; Lars Schropp; Erik Gotfredsen; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2016-10-27       Impact factor: 2.419

7.  The growing concern of radiation dose in paediatric dental and maxillofacial CBCT: an easy guide for daily practice.

Authors:  Andreas Stratis; Guozhi Zhang; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans
Journal:  Eur Radiol       Date:  2019-07-01       Impact factor: 5.315

8.  Dose indices in dental cone beam CT and correlation with dose-area product.

Authors:  K Araki; S Patil; A Endo; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

9.  A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures.

Authors:  H Lang; J Neubauer; B Fritz; E M Spira; J Strube; M Langer; E Kotter
Journal:  Eur Radiol       Date:  2016-03-22       Impact factor: 5.315

10.  A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

Authors:  R Pauwels; O Silkosessak; R Jacobs; R Bogaerts; H Bosmans; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2014-04-08       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.