Literature DB >> 22743072

Biomechanical performance of subpectoral biceps tenodesis: a comparison of interference screw fixation, cortical button fixation, and interference screw diameter.

Paul M Sethi1, Arun Rajaram, Knut Beitzel, Thomas R Hackett, David M Chowaniec, Augustus D Mazzocca.   

Abstract

BACKGROUND: Subpectoral biceps tenodesis with interference screw fixation allows reproducible positioning of the tendon to help maintain the length-tension relationship. The aim of our study was to evaluate the role of cortical button fixation in isolation or as an augment to interference screw fixation and to determine if the diameter of the interference screw affected fixation strength.
MATERIALS AND METHODS: Thirty-two cadaveric shoulders were dissected and randomized to 1 of 4 groups: (1) 7-mm interference screw and cortical button, (2) cortical button alone, (3) 7-mm interference screw, or (4) 8-mm interference screw. Testing was performed on a materials testing system with a 100-N load cycled at 1 Hz for 5000 cycles, followed by an axial load to failure test. Cyclic displacement, ultimate load to failure, and site of failure were recorded for each specimen.
RESULTS: The mean ultimate failure loads were 7-mm interference screw with cortical button augmentation, 237.8 ± 120.4 N; cortical button alone, 99.4 ± 16.9 N; 7-mm interference screw, 275.5 ± 56 N; 8-mm interference screw, 277.1 ± 42.1 N. All specimens failed through tendon failure at the screw-tendon-bone interface.
CONCLUSIONS: The biomechanical performance of subpectoral biceps tenodesis with interference screw fixation was not improved with cortical button augmentation. In addition, cortical button fixation alone yielded a significantly lower ultimate load to failure compared with interference screws. Finally, the biomechanical performance of smaller-diameter interference screws with matching bone tunnels was not affected by interference screw diameter.
Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22743072     DOI: 10.1016/j.jse.2012.03.016

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  18 in total

1.  A cadaveric assessment of the risk of nerve injury during open subpectoral biceps tenodesis using a bicortical guidewire.

Authors:  Adnan Saithna; Alison Longo; R W Jordan; Jeff Leiter; Peter MacDonald; Jason Old
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-06       Impact factor: 4.342

2.  Biomechanical characterization of unicortical button fixation: a novel technique for proximal subpectoral biceps tenodesis.

Authors:  Joseph P DeAngelis; Alvin Chen; Michael Wexler; Benjamin Hertz; Leandro Grimaldi Bournissaint; Ara Nazarian; Arun J Ramappa
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-20       Impact factor: 4.342

3.  A Simple, All-Arthroscopic, Knotless Suture Lasso Loop Technique for Suprapectoral Biceps Tenodesis.

Authors:  David Saper; Xinning Li
Journal:  Arthrosc Tech       Date:  2017-05-22

4.  Low incidence of failure after proximal biceps tenodesis with unicortical suture button.

Authors:  Jay B Cook; David M Sedory; Michael C Freidl; Douglas R Adams
Journal:  J Orthop       Date:  2017-06-27

5.  [Subpectoral tenodesis of the long head of the biceps tendon with an interference screw and a cortical button : Clinical and cosmetic results after 1 year].

Authors:  P-C Nolte; N Pister; F Holz; M Egenolf; T Chatterjee
Journal:  Orthopade       Date:  2017-10       Impact factor: 1.087

6.  The biomechanical performance of a new forked knotless biceps tenodesis compared to a knotless and suture anchor tenodesis.

Authors:  Olaf Lorbach; Christian Trennheuser; Dieter Kohn; Konstantinos Anagnostakos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-08       Impact factor: 4.342

7.  Biomechanical properties of tenotomy versus biceps knot in a cadaver model.

Authors:  Micah Lissy; Amanda Esquivel; Allison Cracchiolo; Stephen Lemos
Journal:  J Orthop       Date:  2016-05-06

8.  Proximity of the axillary nerve during bicortical drilling for biceps tenodesis.

Authors:  Sarah Lancaster; Geoff Smith; Oluwafunto Ogunleye; Iain Packham
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-10       Impact factor: 4.342

9.  Long head of biceps tenodesis at the superior aspect of the biceps groove: A biomechanical comparison of inlay and onlay techniques.

Authors:  Paul J Cagle; Daniel A London; Matthew J Gluck; Sabrina Morel; Bradford O Parsons
Journal:  Shoulder Elbow       Date:  2018-12-04

10.  Long Biceps Subpectoral Tenodesis With Suspensory Button and Bicortical Fixation.

Authors:  Nuno Gomes; Manuel Ribeiro da Silva; Helder Pereira; Ricardo Aido; Ricardo Sampaio
Journal:  Arthrosc Tech       Date:  2017-07-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.