Literature DB >> 22732564

Improving diffusion MRI using simultaneous multi-slice echo planar imaging.

K Setsompop1, J Cohen-Adad, B A Gagoski, T Raij, A Yendiki, B Keil, V J Wedeen, L L Wald.   

Abstract

In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high g-factor penalties (i.e., lower SNR). The CAIPIRINHA technique was developed to reduce the g-factor in simultaneous multi-slice acquisitions by introducing inter-slice image shifts and thus increase the distance between aliased voxels. Because the CAIPIRINHA technique achieved this by controlling the phase of the RF excitations for each line of k-space, it is not directly applicable to single-shot EPI employed in conventional diffusion imaging. We adopt a recent gradient encoding method, which we termed "blipped-CAIPI", to create the image shifts needed to apply CAIPIRINHA to EPI. Here, we use pseudo-multiple replica SNR and bootstrapping metrics to assess the performance of the blipped-CAIPI method in 3× simultaneous multi-slice diffusion studies. Further, we introduce a novel image reconstruction method to reduce detrimental ghosting artifacts in these acquisitions. We show that data acquisition times for Q-ball and diffusion spectrum imaging (DSI) can be reduced 3-fold with a minor loss in SNR and with similar diffusion results compared to conventional acquisitions.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22732564      PMCID: PMC3429710          DOI: 10.1016/j.neuroimage.2012.06.033

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  37 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Simultaneous echo refocusing in EPI.

Authors:  David A Feinberg; Timothy G Reese; Van J Wedeen
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study.

Authors:  Derek K Jones
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

4.  Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution.

Authors:  J-Donald Tournier; Fernando Calamante; David G Gadian; Alan Connelly
Journal:  Neuroimage       Date:  2004-11       Impact factor: 6.556

5.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  Accelerated volumetric MRI with a SENSE/GRAPPA combination.

Authors:  Martin Blaimer; Felix A Breuer; Nicole Seiberlich; Matthias F Mueller; Robin M Heidemann; Vladimir Jellus; Graham Wiggins; Lawrence L Wald; Mark A Griswold; Peter M Jakob
Journal:  J Magn Reson Imaging       Date:  2006-08       Impact factor: 4.813

7.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Simultaneous multislice acquisition of MR images.

Authors:  J B Weaver
Journal:  Magn Reson Med       Date:  1988-11       Impact factor: 4.668

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging.

Authors:  David A Feinberg; Steen Moeller; Stephen M Smith; Edward Auerbach; Sudhir Ramanna; Matthias Gunther; Matt F Glasser; Karla L Miller; Kamil Ugurbil; Essa Yacoub
Journal:  PLoS One       Date:  2010-12-20       Impact factor: 3.240

View more
  140 in total

1.  Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA.

Authors:  Lukas Filli; Marco Piccirelli; David Kenkel; Andreas Boss; Andrei Manoliu; Gustav Andreisek; Himanshu Bhat; Val M Runge; Roman Guggenberger
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

2.  High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS).

Authors:  Kawin Setsompop; Qiuyun Fan; Jason Stockmann; Berkin Bilgic; Susie Huang; Stephen F Cauley; Aapo Nummenmaa; Fuyixue Wang; Yogesh Rathi; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

3.  Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI.

Authors:  Kangrong Zhu; Robert F Dougherty; Hua Wu; Matthew J Middione; Atsushi M Takahashi; Tao Zhang; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-02-18       Impact factor: 10.048

4.  Multishell Diffusion MRI-Based Tractography of the Facial Nerve in Vestibular Schwannoma.

Authors:  M Castellaro; M Moretto; V Baro; S Brigadoi; E Zanoletti; M Anglani; L Denaro; R Dell'Acqua; A Landi; F Causin; D d'Avella; A Bertoldo
Journal:  AJNR Am J Neuroradiol       Date:  2020-07-30       Impact factor: 3.825

5.  Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage.

Authors:  Cornelius Eichner; Kourosh Jafari-Khouzani; Stephen Cauley; Himanshu Bhat; Pavlina Polaskova; Ovidiu C Andronesi; Otto Rapalino; Robert Turner; Lawrence L Wald; Steven Stufflebeam; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2013-10-28       Impact factor: 4.668

Review 6.  Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging.

Authors:  Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2018-08-04

7.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

Review 8.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

9.  Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

Authors:  Bastien Guérin; Kawin Setsompop; Huihui Ye; Benedikt A Poser; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-17       Impact factor: 4.668

10.  Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T.

Authors:  Samantha By; Alex K Smith; Lindsey M Dethrage; Bailey D Lyttle; Bennett A Landman; Jeffrey L Creasy; Siddharama Pawate; Seth A Smith
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.