Lukas Filli1, Marco Piccirelli2, David Kenkel3, Andreas Boss3, Andrei Manoliu3, Gustav Andreisek3, Himanshu Bhat4, Val M Runge3, Roman Guggenberger3. 1. Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Raemistrasse 100, CH-8091, Zurich, Switzerland. lukas.filli@usz.ch. 2. Department of Neuroradiology, University Hospital of Zurich, Zurich, Switzerland. 3. Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Raemistrasse 100, CH-8091, Zurich, Switzerland. 4. Siemens Medical Solutions USA Inc, Charlestown, MA, USA.
Abstract
PURPOSE: To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS: After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS: Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION: Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS: • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.
PURPOSE: To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS: After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS: Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION: Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS: • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.
Authors: Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob Journal: Magn Reson Med Date: 2005-03 Impact factor: 4.668
Authors: Cornelius Eichner; Kourosh Jafari-Khouzani; Stephen Cauley; Himanshu Bhat; Pavlina Polaskova; Ovidiu C Andronesi; Otto Rapalino; Robert Turner; Lawrence L Wald; Steven Stufflebeam; Kawin Setsompop Journal: Magn Reson Med Date: 2013-10-28 Impact factor: 4.668
Authors: Roman Guggenberger; Daniel Nanz; Lorenz Bussmann; Avneesh Chhabra; Michael A Fischer; Jürg Hodler; Christian W A Pfirrmann; Gustav Andreisek Journal: Eur J Radiol Date: 2013-06-12 Impact factor: 3.528
Authors: Angus Z Lau; Elizabeth M Tunnicliffe; Robert Frost; Peter J Koopmans; Damian J Tyler; Matthew D Robson Journal: Magn Reson Med Date: 2014-03-21 Impact factor: 4.668
Authors: A S Klauser; M Abd Ellah; C Kremser; M Taljanovic; G Schmidle; M Gabl; F Cartes-Zumelzu; R Steiger; E R Gizewski Journal: Eur Radiol Date: 2017-09-27 Impact factor: 5.315
Authors: Felix P Kuhn; Georg Spinner; Filippo Del Grande; Michael Wyss; Marco Piccirelli; Stefan Erni; Pascal Pfister; Michael Ho; Bert-Ram Sah; Lukas Filli; Dominik A Ettlin; Luigi M Gallo; Gustav Andreisek; Andrei Manoliu Journal: Dentomaxillofac Radiol Date: 2016-12-18 Impact factor: 2.419
Authors: Moritz Kronlage; Véronique Schwehr; Daniel Schwarz; Tim Godel; Lorenz Uhlmann; Sabine Heiland; Martin Bendszus; Philipp Bäumer Journal: Eur Radiol Date: 2017-12-11 Impact factor: 5.315
Authors: Annina B Schmid; Jon Campbell; Samuel A Hurley; Saad Jbabdi; Jesper L Andersson; Mark Jenkinson; Neal K Bangerter; David L Bennett; Irene Tracey; Robert Frost; Stuart Clare Journal: Invest Radiol Date: 2018-12 Impact factor: 6.016
Authors: Barbara Cervantes; Anh T Van; Dominik Weidlich; Hendrick Kooijman; Andreas Hock; Ernst J Rummeny; Alexandra Gersing; Jan S Kirschke; Dimitrios C Karampinos Journal: Magn Reson Med Date: 2018-01-29 Impact factor: 4.668