Literature DB >> 22684409

Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements.

Mark Lewis1, Karen Reid, Andoni P Toms.   

Abstract

PURPOSE: The aim of this study was to determine whether high keV monoenergetic reconstruction of dual energy computed tomography (DECT) could be used to overcome the effects of beam hardening artefact that arise from preferential deflection of low energy photons.
MATERIALS AND METHODS: Two phantoms were used: a Charnley total hip replacement set in gelatine and a Catphan 500. DECT datasets were acquired at 100, 200 and 400 mA (Siemens Definition Flash, 100 and 140 kVp) and reconstructed using a standard combined algorithm (1:1) and then as monoenergetic reconstructions at 10 keV intervals from 40 to 190 keV. Semi-automated segmentation with threshold inpainting was used to obtain the attenuation values and standard deviation (SD) of the streak artefact. High contrast line pair resolution and background noise were assessed using the Catphan 500.
RESULTS: Streak artefact is progressively reduced with increasing keV monoenergetic reconstructions. Reconstruction of a 400 mA acquisition at 150 keV results in reduction in the volume of streak artefact from 65 cm(3) to 17 cm(3) (74 %). There was a decrease in the contrast to noise ratio (CNR) at higher tube voltages, with the peak CNR seen at 70-80 keV. High contrast spatial resolution was maintained at high keV values.
CONCLUSION: Monoenergetic reconstruction of dual energy CT at increasing theoretical kilovoltages reduces the streak artefact produced by beam hardening from orthopaedic prostheses, accompanied by a modest increase in heterogeneity of background image attenuation, and decrease in contrast to noise ratio, but no deterioration in high contrast line pair resolution.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22684409     DOI: 10.1007/s00256-012-1458-6

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  21 in total

1.  Musculoskeletal imaging with multislice CT.

Authors:  K A Buckwalter; J Rydberg; K K Kopecky; K Crow; E L Yang
Journal:  AJR Am J Roentgenol       Date:  2001-04       Impact factor: 3.959

2.  Fast iterative algorithm for metal artifact reduction in X-ray CT.

Authors:  G Wang; T Frei; M W Vannier
Journal:  Acad Radiol       Date:  2000-08       Impact factor: 3.173

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study.

Authors:  C L Brown; R P Hartman; O P Dzyubak; N Takahashi; A Kawashima; C H McCollough; M R Bruesewitz; A M Primak; J G Fletcher
Journal:  Eur Radiol       Date:  2009-01-20       Impact factor: 5.315

Review 5.  Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient.

Authors:  Laura M Fayad; Ajanta Patra; Elliot K Fishman
Journal:  AJR Am J Roentgenol       Date:  2009-10       Impact factor: 3.959

6.  Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images.

Authors:  Carlo Nicola De Cecco; Vitaliano Buffa; Stefano Fedeli; Monica Luzietti; Andrea Vallone; Roberto Ruopoli; Vittorio Miele; Marco Rengo; Pasquale Paolantonio; Michelangelo Maurizi Enrici; Andrea Laghi; Vincenzo David
Journal:  Eur Radiol       Date:  2010-07-11       Impact factor: 5.315

7.  CT of metal implants: reduction of artifacts using an extended CT scale technique.

Authors:  T M Link; W Berning; S Scherf; U Joosten; A Joist; K Engelke; H E Daldrup-Link
Journal:  J Comput Assist Tomogr       Date:  2000 Jan-Feb       Impact factor: 1.826

8.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

9.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

10.  Influence of dental metallic artifact from multislice CT in the assessment of simulated mandibular lesions.

Authors:  Andréia Perrella; Patricia M L Lopes; Rodney G Rocha; Marlene Fenyo-Pereira; Marcelo G P Cavalcanti
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

View more
  32 in total

Review 1.  3D printing from diagnostic images: a radiologist's primer with an emphasis on musculoskeletal imaging-putting the 3D printing of pathology into the hands of every physician.

Authors:  Tamir Friedman; Mark Michalski; T Rob Goodman; J Elliott Brown
Journal:  Skeletal Radiol       Date:  2015-11-23       Impact factor: 2.199

Review 2.  Clinical applications of dual-energy CT in head and neck imaging.

Authors:  Daniel Thomas Ginat; Michael Mayich; Laleh Daftari-Besheli; Rajiv Gupta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-04       Impact factor: 2.503

3.  Metal artefact reduction in CT imaging of hip prostheses—an evaluation of commercial techniques provided by four vendors.

Authors:  K M Andersson; P Nowik; J Persliden; P Thunberg; E Norrman
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

Review 4.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

Review 5.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

6.  Case-control study to estimate the performance of dual-energy computed tomography for anterior cruciate ligament tears in patients with history of knee trauma.

Authors:  Katrina N Glazebrook; Lee J Brewerton; Shuai Leng; Rickey E Carter; Peter C Rhee; Naveen S Murthy; B Mathew Howe; Michael D Ringler; Diane L Dahm; Michael J Stuart; Cynthia H McCollough; J G Fletcher
Journal:  Skeletal Radiol       Date:  2013-12-14       Impact factor: 2.199

7.  CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar.

Authors:  Kai Roman Laukamp; Simon Lennartz; Victor-Frederic Neuhaus; Nils Große Hokamp; Robert Rau; Markus Le Blanc; Nuran Abdullayev; Anastasios Mpotsaris; David Maintz; Jan Borggrefe
Journal:  Eur Radiol       Date:  2018-05-03       Impact factor: 5.315

8.  Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?

Authors:  An De Crop; Jan Casselman; Tom Van Hoof; Melissa Dierens; Elke Vereecke; Nicolas Bossu; Jaime Pamplona; Katharina D'Herde; Hubert Thierens; Klaus Bacher
Journal:  Neuroradiology       Date:  2015-05-01       Impact factor: 2.804

9.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

Authors:  Shuai Leng; Lifeng Yu; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2015-04-10       Impact factor: 11.105

10.  Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts.

Authors:  Kai Roman Laukamp; David Zopfs; Simon Lennartz; Lenhard Pennig; David Maintz; Jan Borggrefe; Nils Große Hokamp
Journal:  Eur Radiol       Date:  2019-01-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.