Literature DB >> 22644825

Comparative analysis of 2-D versus 3-D ultrasound estimation of the fetal adrenal gland volume and prediction of preterm birth.

Ozhan M Turan1, Sifa Turan, Irina A Buhimschi, Edmund F Funai, Katherine H Campbell, Ozan M Bahtiyar, Chris R Harman, Joshua A Copel, Ahmet A Baschat, Catalin S Buhimschi.   

Abstract

OBJECTIVE: We aim to test the hypothesis that two-dimensional (2-D) fetal adrenal gland volume (AGV) measurements offer similar volume estimates as volume calculations based on 3-D technique.
METHODS: Fetal AGV was estimated by three-dimensional (3-D) ultrasound (VOCAL) in 93 women with signs/symptoms of preterm labor and 73 controls. Fetal AGV was calculated using an ellipsoid formula derived from 2-D measurements of the same blocks (0.523 × length × width × depth). Comparisons were performed by intraclass correlation coefficient (ICC), coefficient of repeatability, and Bland-Altman method. The corrected AGV (cAGV; AGV/fetal weight) was calculated for both methods and compared for prediction of preterm birth (PTB) within 7 days.
RESULTS: Among 168 volumes, there was a significant correlation between 3-D and 2-D methods (ICC = 0.979; 95% confidence interval [CI]: 0.971 to 0.984). The coefficient of repeatability for the 3-D was superior to the 2-D method (intraobserver 3-D: 30.8, 2-D:57.6; interobserver 3-D:12.2, 2-D: 15.6). Based on 2-D calculations, cAGV ≥ 433 mm3/kg was best for prediction of PTB (sensitivity: 75%, 95% CI = 59 to 87; specificity: 89%, 95% CI = 82 to 94). Sensitivity and specificity for the 3-D cAGV (cutoff ≥ 420 mm3/kg) was 85% (95% CI = 70 to 94) and 95% (95% CI = 90 to 98), respectively. In receiver-operating-curve curve analysis, 3-D cAGV was superior to 2-D cAGV for prediction of PTB (z = 1.99, p = 0.047).
CONCLUSION: 2-D volume estimation of fetal adrenal gland using ellipsoid formula cannot replace 3-D AGV calculations for prediction of PTB. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2012        PMID: 22644825      PMCID: PMC3838705          DOI: 10.1055/s-0032-1314887

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  22 in total

1.  Receiver operating characteristic plots to evaluate Guthrie, Wallac, and Isolab phenylalanine kit performance for newborn phenylketonuria screening.

Authors:  S T Wang; S Pizzolato; H P Demshar
Journal:  Clin Chem       Date:  1997-10       Impact factor: 8.327

2.  Accuracy and precision of in vitro volumetric measurements by three-dimensional sonography.

Authors:  J Wong; E O Gerscovich; M S Cronan; J A Seibert
Journal:  Invest Radiol       Date:  1996-01       Impact factor: 6.016

3.  Three-dimensional ultrasound: accuracy of distance and volume measurements.

Authors:  M Riccabona; T R Nelson; D H Pretorius
Journal:  Ultrasound Obstet Gynecol       Date:  1996-06       Impact factor: 7.299

4.  Size of the fetal adrenal in bilateral renal agenesis.

Authors:  S Droste; J Fitzsimmons; J Pascoe-Mason; T H Shepard; L A Mack
Journal:  Obstet Gynecol       Date:  1990-08       Impact factor: 7.661

5.  Estimation of nongravid uterine volume based on a nomogram of gravid uterine volume: its value in gynecologic uterine abnormalities.

Authors:  S R Goldstein; S C Horii; J R Snyder; B N Raghavendra; B Subramanyam
Journal:  Obstet Gynecol       Date:  1988-07       Impact factor: 7.661

6.  Transvaginal three-dimensional ultrasound: reproducibility of ovarian and endometrial volume measurements.

Authors:  A Kyei-Mensah; N Maconochie; J Zaidi; R Pittrof; S Campbell; S L Tan
Journal:  Fertil Steril       Date:  1996-11       Impact factor: 7.329

7.  Intraobserver and interobserver variations in sonographic measurements of kidney size in adult volunteers. A comparison of linear measurements and volumetric estimates.

Authors:  S A Emamian; M B Nielsen; J F Pedersen
Journal:  Acta Radiol       Date:  1995-07       Impact factor: 1.990

8.  The accuracy of a hand-held real time ultrasound scanner for estimating bladder volume.

Authors:  G Ravichandran; G J Fellows
Journal:  Br J Urol       Date:  1983-02

9.  Accuracy of three-dimensional ultrasonography in volume estimation of cervical carcinoma.

Authors:  C Y Chou; K F Hsu; S T Wang; S C Huang; C C Tzeng; K E Huang
Journal:  Gynecol Oncol       Date:  1997-07       Impact factor: 5.482

10.  ACOG practice bulletin. Management of preterm labor. Number 43, May 2003.

Authors: 
Journal:  Int J Gynaecol Obstet       Date:  2003-07       Impact factor: 3.561

View more
  2 in total

1.  Fetal Adrenal Gland Volume a Novel Predictor of Onset of Labor.

Authors:  Chandana S Bhat; Sapna Vinit Amin; Prashanth Adiga; Deeksha Pandey
Journal:  J Obstet Gynaecol India       Date:  2018-11-21

2.  Longitudinal adrenal gland measurements and growth trajectories as risk markers for late preterm delivery.

Authors:  Janina Goletzke; Mirja Pagenkemper; Christian Wiessner; Franziska Rüber; Petra Arck; Kurt Hecher; Anke Diemert
Journal:  BMC Pregnancy Childbirth       Date:  2020-09-29       Impact factor: 3.007