Literature DB >> 8807760

Three-dimensional ultrasound: accuracy of distance and volume measurements.

M Riccabona1, T R Nelson, D H Pretorius.   

Abstract

The aim of this study was to evaluate the accuracy of three-dimensional ultrasound distance and volume measurements using a commercially available three-dimensional ultrasound scanner. Sixty-two distance measurements were performed twice on an ultrasound tissue-mimicking phantom located in a water bath. Three-dimensional ultrasound distance measurements were compared to the actual distance. Volume measurements were made in a water bath with 21 balloons of various shapes ranging in volume from 20 ml to 490 ml. Three-dimensional ultrasound volume measurements were compared to actual balloon volumes and to conventional two-dimensional ultrasound volume calculations. The mean absolute error in three-dimensional ultrasound distance measurements was 1.0 +/- 0.8% (range, -2.3 to +1.9%) in the plane of acquisition and 1.0 +/- 0.6% (range, -2.0 to -0.2%) for planes with other orientations. Three-dimensional ultrasound volume measurements showed a mean absolute error of 6.4 +/- 4.4% (range, -6.0% to +15.5%), which was considerably better than two-dimensional ultrasound volume estimates having a mean absolute error of 12.6 +/- 8.7% (range, -27.5% to +39.2%). Volume measurements using two-dimensional ultrasound methods were much less accurate than three-dimensional ultrasound methods for irregularly shaped objects. In conclusion, our data show that three-dimensional ultrasound measurements of distance and volume are sufficiently accurate to use clinically.

Entities:  

Mesh:

Year:  1996        PMID: 8807760     DOI: 10.1046/j.1469-0705.1996.07060429.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  25 in total

1.  Reproducibility of fetal heart volume by 3D-sonography using the XI VOCAL method.

Authors:  Enoch Q Barreto; Hérbene F Milani; Edward Araujo Júnior; Karina K Haratz; Liliam C Rolo; Luciano M Nardozza; Hélio A Guimarães Filho; Antonio F Moron
Journal:  Cardiovasc Ultrasound       Date:  2010-05-12       Impact factor: 2.062

2.  Potential of three-dimensional ultrasound in neonatal and paediatric neurosonography.

Authors:  M Riccabona; T R Nelson; C Weitzer; B Resch; D P Pretorius
Journal:  Eur Radiol       Date:  2003-03-06       Impact factor: 5.315

3.  Comparative analysis of 2-D versus 3-D ultrasound estimation of the fetal adrenal gland volume and prediction of preterm birth.

Authors:  Ozhan M Turan; Sifa Turan; Irina A Buhimschi; Edmund F Funai; Katherine H Campbell; Ozan M Bahtiyar; Chris R Harman; Joshua A Copel; Ahmet A Baschat; Catalin S Buhimschi
Journal:  Am J Perinatol       Date:  2012-05-29       Impact factor: 1.862

Review 4.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

Review 5.  Gestation-Specific Changes in the Anatomy and Physiology of Healthy Pregnant Women: An Extended Repository of Model Parameters for Physiologically Based Pharmacokinetic Modeling in Pregnancy.

Authors:  André Dallmann; Ibrahim Ince; Michaela Meyer; Stefan Willmann; Thomas Eissing; Georg Hempel
Journal:  Clin Pharmacokinet       Date:  2017-11       Impact factor: 6.447

6.  The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Authors:  J P Kusanovic; J K Nien; L F Gonçalves; J Espinoza; W Lee; M Balasubramaniam; E Soto; O Erez; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299

7.  Intraobserver variability in fibroid size measurements: estimated effects on assessing fibroid growth.

Authors:  Malana Moshesh; Shyamal D Peddada; Tracy Cooper; Donna Baird
Journal:  J Ultrasound Med       Date:  2014-07       Impact factor: 2.153

Review 8.  Three-dimensional ultrasound as a predictor of pregnancy in patients undergoing ART.

Authors:  Cemil Yaman; Richard Mayer
Journal:  J Turk Ger Gynecol Assoc       Date:  2012-06-01

9.  The role of chemotherapeutic drugs in the evaluation of breast tumour response to chemotherapy using serial FDG-PET.

Authors:  Michal E Schneider-Kolsky; Stewart Hart; Jane Fox; Peter Midolo; John Stuckey; Michael Hofman; Vinod Ganju
Journal:  Breast Cancer Res       Date:  2010-06-21       Impact factor: 6.466

10.  Renal dimensions measured by ultrasonography in children: variations as a function of the imaging plane and patient position.

Authors:  Sven C Michel; Ishilde Forster; Burkhardt Seifert; Ulrich V Willi; Thierry A G M Huisman
Journal:  Eur Radiol       Date:  2004-04-28       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.