Literature DB >> 9234927

Accuracy of three-dimensional ultrasonography in volume estimation of cervical carcinoma.

C Y Chou1, K F Hsu, S T Wang, S C Huang, C C Tzeng, K E Huang.   

Abstract

OBJECTIVE: To evaluate the accuracy of a three-dimensional (3D) ultrasound system in volume estimation of cervical carcinoma. STUDY
DESIGN: Transvaginal 3D and two-dimensional (2D) scans on cervical carcinoma volumes were performed 1 day before surgery. The volume of cervical carcinoma measured from each surgical specimen was compared with the corresponding volume of the cervical tumor measured by a 3D ultrasound and with the conventional 2D ultrasound volume measurement calculated using the formula pi/6 x(R1 x R2 x R3), where R1, R2, and R3 were the maximal transverse, anteroposterior, and longitudinal length of tumor, respectively. Limits of agreement and 95% confidence intervals were calculated and systemic bias between the methods was analyzed. The Klotz test was also used to assess the statistical significance of the degree of dispersion.
RESULTS: A total of 61 cases, 55 with exophytic tumors and 6 with endocervical tumors, were examined in this study. The limits of agreement between the volume measured from specimen and tumor volume determined by ultrasound were +6.68 to -6.10 mL for 3D measurements and +12.46 to -10.98 mL for 2D measurements. The Klotz test showed the discrepancy in the degree of dispersion between 3D and 2D ultrasound measurements was statistically significant (P = 0.01).
CONCLUSION: The true volume of cervical carcinoma is measured more accurately by a 3D ultrasound system than 2D ultrasound.

Entities:  

Mesh:

Year:  1997        PMID: 9234927     DOI: 10.1006/gyno.1997.4714

Source DB:  PubMed          Journal:  Gynecol Oncol        ISSN: 0090-8258            Impact factor:   5.482


  6 in total

Review 1.  The role of ultrasound in the assessment of uterine cervical cancer.

Authors:  Juan Luis Alcázar; Sara Arribas; José Angel Mínguez; Matías Jurado
Journal:  J Obstet Gynaecol India       Date:  2014-10-08

2.  Comparative analysis of 2-D versus 3-D ultrasound estimation of the fetal adrenal gland volume and prediction of preterm birth.

Authors:  Ozhan M Turan; Sifa Turan; Irina A Buhimschi; Edmund F Funai; Katherine H Campbell; Ozan M Bahtiyar; Chris R Harman; Joshua A Copel; Ahmet A Baschat; Catalin S Buhimschi
Journal:  Am J Perinatol       Date:  2012-05-29       Impact factor: 1.862

3.  The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Authors:  J P Kusanovic; J K Nien; L F Gonçalves; J Espinoza; W Lee; M Balasubramaniam; E Soto; O Erez; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299

4.  Three-Dimensional Carpal Arch Morphology Using Robot-Assisted Ultrasonography.

Authors:  Rakshit Shah; Zong-Ming Li
Journal:  IEEE Trans Biomed Eng       Date:  2022-01-20       Impact factor: 4.756

5.  Comparison of cervical parameters by three-dimensional ultrasound according to parity and previous delivery mode.

Authors:  Yun Sung Jo; Dong Gyu Jang; Narinay Kim; Sa Jin Kim; Guisera Lee
Journal:  Int J Med Sci       Date:  2011-10-21       Impact factor: 3.738

6.  Clinical efficacy of cervical length and volume for prediction of labor onset in VBAC candidates.

Authors:  Yun Sung Jo; Gui Se Ra Lee; Narinay Kim; Dong Gyu Jang; Sa Jin Kim; Young Lee
Journal:  Int J Med Sci       Date:  2012-10-17       Impact factor: 3.738