Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.

Naveen M Kulkarni1, Dushyant V Sahani, Gaurav S Desai, Sanjeeva P Kalva.   

Abstract

PURPOSE: To study the performance of dual-energy indirect computed tomography (CT) venography from single-source dual-energy CT in the assessment of lower extremity deep venous thrombosis (DVT).
MATERIALS AND METHODS: In a retrospective study, 110 patients suspected to have pulmonary embolism (PE) underwent dual-energy CT venography on a single-source dual-energy CT scanner as a part of CT pulmonary angiography protocol at 3 minutes after injection of contrast material. Two radiologists evaluated 50-kiloelectron volt (keV) and 70-keV monochromatic images reconstructed from a dual-energy CT scan for image quality, image noise, venous contrast, and confidence level in interpretation for DVT using a scale of 1-5. In addition, a combined 50-keV and 70-keV data set was assessed for confidence level in image interpretation. Attenuation, contrast-to-noise ratio (CNR), and objective noise were measured in bilateral common femoral and popliteal veins. Data were analyzed using Student t test and Wilcoxon rank sum test. Radiation dose was measured for dual-energy CT venography protocol.
RESULTS: A diagnosis of DVT was made in 8 of 110 patients (7.27%). The subjective image quality was comparable between 50-keV and 70-keV images (4.3 vs 4.5; P > .05). The subjective venous contrast opacification (4.7 vs 3.5; P = .0036) and confidence (4.8 vs 3.9; P = .0028) in image interpretation were superior at 50 keV. Confidence level for interpretation on combined 50-keV and 70-keV series (score 4.7) was similar to that for 50-keV series (score 4.8). Compared with 70-keV data, 50-keV data yielded 90% increase in intravascular CT attenuation (207.4 Hounsfield units [HU] ± 39.0 vs 106.8 HU ± 7.6; P <.0001) and higher CNR (10.7 ± 4.07 vs 7.2 ± 4.1; P = .0001) of the deep veins. However, objective noise at 50 keV was higher (14.8 HU vs 6.5 HU; P = .0031). Because of inadequate contrast opacification, 6% of CT venography studies were deemed suboptimal for rendering a diagnostic interpretation on 70-keV images, but these images were considered acceptable at 50 keV. The mean effective radiation dose for the dual-energy CT venography examination was 4.2 mSv.
CONCLUSIONS: Optimal image quality with substantially higher venous attenuation is provided by 50-keV monochromatic images from dual-energy CT venography acquisition compared with 70-keV images. The 50-keV monochromatic images increase the confidence in the image interpretation of DVT and decrease the number of indeterminate studies.
Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22633619     DOI: 10.1016/j.jvir.2012.04.012

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  12 in total

1.  Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp.

Authors:  Jin Hyeok Kim; Ki Seok Choo; Tae Yong Moon; Jun Woo Lee; Ung Bae Jeon; Tae Un Kim; Jae Yeon Hwang; Myeong-Ja Yun; Dong Wook Jeong; Soo Jin Lim
Journal:  Eur Radiol       Date:  2015-10-20       Impact factor: 5.315

2.  Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation.

Authors:  Chan Kue Park; Ki Seok Choo; Ung Bae Jeon; Seung Kug Baik; Yong Woo Kim; Tae Un Kim; Chang Won Kim; Yeon Ju Jeong; Dong Wook Jeong; Soo Jin Lim
Journal:  Int J Cardiovasc Imaging       Date:  2013-06-09       Impact factor: 2.357

3.  Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study.

Authors:  Malte N Bongers; Christoph Schabel; Bernhard Krauss; Ilias Tsiflikas; Dominik Ketelsen; Stefanie Mangold; Claus D Claussen; Konstantin Nikolaou; Christoph Thomas
Journal:  Eur Radiol       Date:  2014-12-21       Impact factor: 5.315

4.  Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions.

Authors:  Lorenzo Mannelli; Lee M Mitsumori; Marina Ferguson; Dongxiang Xu; Baocheng Chu; Kelley R Branch; William P Shuman; Chun Yuan
Journal:  Eur Radiol       Date:  2012-08-21       Impact factor: 5.315

5.  Comparative study of hepatic venography using non-linear-blending images, monochromatic images and low-voltage images of dual-energy CT.

Authors:  Q Wang; S Gaofeng; F Xueli; W Lijia; W Runze
Journal:  Br J Radiol       Date:  2014-07-23       Impact factor: 3.039

6.  Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction.

Authors:  Dong Han; Xiaoxia Chen; Yuxin Lei; Chunling Ma; Jieli Zhou; Yingcong Xiao; Yong Yu
Journal:  Br J Radiol       Date:  2019-07-10       Impact factor: 3.039

Review 7.  Spectral detector CT applications in advanced liver imaging.

Authors:  Noor Fatima Majeed; Marta Braschi Amirfarzan; Christoph Wald; Jeremy R Wortman
Journal:  Br J Radiol       Date:  2021-05-28       Impact factor: 3.629

8.  Combined Direct and Indirect CT Venography (Combined CTV) in Detecting Lower Extremity Deep Vein Thrombosis.

Authors:  Wan-Yin Shi; Li-Wei Wang; Shao-Juan Wang; Xin-Dao Yin; Jian-Ping Gu
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

9.  Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT.

Authors:  Makoto Sakane; Tonsok Kim; Masatoshi Hori; Hiromitsu Onishi; Atsushi Nakamoto; Takahiro Tsuboyama; Mitsuaki Tatsumi; Noriyuki Tomiyama
Journal:  Springerplus       Date:  2014-05-08

10.  Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose.

Authors:  Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Sung Min Ko
Journal:  PLoS One       Date:  2016-09-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.