Literature DB >> 26486938

Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp.

Jin Hyeok Kim1, Ki Seok Choo2, Tae Yong Moon1, Jun Woo Lee1, Ung Bae Jeon1, Tae Un Kim1, Jae Yeon Hwang1, Myeong-Ja Yun3, Dong Wook Jeong4, Soo Jin Lim5.   

Abstract

PURPOSE: To evaluate the subjective and objective qualities of computed tomography (CT) venography images at 80 kVp using model-based iterative reconstruction (MBIR) and to compare these with those of filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) using the same CT data sets.
MATERIALS AND METHODS: Forty-four patients (mean age: 56.1 ± 18.1) who underwent 80 kVp CT venography (CTV) for the evaluation of deep vein thrombosis (DVT) during 4 months were enrolled in this retrospective study. The same raw data were reconstructed using FBP, ASIR, and MBIR. Objective and subjective image analysis were performed at the inferior vena cava (IVC), femoral vein, and popliteal vein.
RESULTS: The mean CNR of MBIR was significantly greater than those of FBP and ASIR and images reconstructed using MBIR had significantly lower objective image noise (p < .001). Subjective image quality and confidence of detecting DVT by MBIR group were significantly greater than those of FBP and ASIR (p < .005), and MBIR had the lowest score for subjective image noise (p < .001).
CONCLUSION: CTV at 80 kVp with MBIR was superior to FBP and ASIR regarding subjective and objective image qualities. KEY POINTS: • MBIR provides superior image quality compared with FBP and ASIR • CTV at 80kVp with MBIR improves diagnostic confidence in diagnosing DVT • CTV at 80kVp with MBIR presents better image quality with low radiation.

Entities:  

Keywords:  Diagnosis; Lower extremity; Multidetector computed tomography; Radiography; Veins

Mesh:

Year:  2015        PMID: 26486938     DOI: 10.1007/s00330-015-4060-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  53 in total

1.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

2.  Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Synho Do; Jean Baptiste Thibault; Homer Pien; Owen J O'Connor; Owen O J Connor; Michael A Blake
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

3.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

4.  Individual modulation of the tube current-seconds to achieve similar levels of image noise in contrast-enhanced abdominal CT.

Authors:  Toshiyuki Irie; Hiroaki Inoue
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

5.  Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation.

Authors:  Chan Kue Park; Ki Seok Choo; Ung Bae Jeon; Seung Kug Baik; Yong Woo Kim; Tae Un Kim; Chang Won Kim; Yeon Ju Jeong; Dong Wook Jeong; Soo Jin Lim
Journal:  Int J Cardiovasc Imaging       Date:  2013-06-09       Impact factor: 2.357

6.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach.

Authors:  Frédéric A Miéville; François Gudinchet; Francis Brunelle; François O Bochud; Francis R Verdun
Journal:  Phys Med       Date:  2012-01-02       Impact factor: 2.685

Review 7.  Deep vein thrombosis.

Authors:  Paul A Kyrle; Sabine Eichinger
Journal:  Lancet       Date:  2005 Mar 26-Apr 1       Impact factor: 79.321

8.  Combined CT venography and pulmonary angiography: how much venous enhancement is routinely obtained?

Authors:  D Bruce; P A Loud; D L Klippenstein; Z D Grossman; D S Katz
Journal:  AJR Am J Roentgenol       Date:  2001-05       Impact factor: 3.959

9.  Benefit of CT venography for the diagnosis of thromboembolic disease.

Authors:  Kyung Hwa Rhee; Ramesh S Iyer; Susan Cha; David P Naidich; Henry Rusinek; Glenn R Jacobowitz; Jane P Ko
Journal:  Clin Imaging       Date:  2007 Jul-Aug       Impact factor: 1.605

10.  CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction.

Authors:  Yasutaka Ichikawa; Kakuya Kitagawa; Naoki Nagasawa; Shuichi Murashima; Hajime Sakuma
Journal:  BMC Med Imaging       Date:  2013-08-09       Impact factor: 1.930

View more
  7 in total

1.  Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

Authors:  André Euler; Bram Stieltjes; Zsolt Szucs-Farkas; Reto Eichenberger; Clemens Reisinger; Anna Hirschmann; Caroline Zaehringer; Achim Kircher; Matthias Streif; Sabine Bucher; David Buergler; Luigia D'Errico; Sebastién Kopp; Markus Wilhelm; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2017-04-03       Impact factor: 5.315

2.  Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study.

Authors:  Atsushi Nakamoto; Yoshikazu Tanaka; Hiroshi Juri; Go Nakai; Shushi Yoshikawa; Yoshifumi Narumi
Journal:  Eur Radiol       Date:  2016-12-12       Impact factor: 5.315

3.  The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose.

Authors:  Cui Feng; Di Zhu; Xianlun Zou; Anqin Li; Xuemei Hu; Zhen Li; Daoyu Hu
Journal:  Medicine (Baltimore)       Date:  2018-03       Impact factor: 1.889

4.  Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp.

Authors:  Chankue Park; Ki Seok Choo; Jin Hyeok Kim; Kyung Jin Nam; Ji Won Lee; Jin You Kim
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

5.  Comparison study of image quality at various radiation doses for CT venography using advanced modeled iterative reconstruction.

Authors:  Jung Han Hwang; Jin Mo Kang; So Hyun Park; Suyoung Park; Jeong Ho Kim; Sang Tae Choi
Journal:  PLoS One       Date:  2021-08-31       Impact factor: 3.240

6.  Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose.

Authors:  Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Sung Min Ko
Journal:  PLoS One       Date:  2016-09-23       Impact factor: 3.240

7.  Low-tube-voltage combined with adaptive statistical iterative reconstruction-V technique in CT venography of lower limb deep vein thrombosis.

Authors:  Dan Chen; Jiahui Zhou; Peixi Wang; Quanxu Ge; Min Xu; Wei Qiu; Xinnan Li; Xiaodong Wang
Journal:  Sci Rep       Date:  2018-07-24       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.