Literature DB >> 22618594

Biometric evaluation of anterior chamber changes after physiologic pupil dilation using Pentacam and anterior segment optical coherence tomography.

Florent Aptel1, Christophe Chiquet, Sylvain Beccat, Philippe Denis.   

Abstract

PURPOSE: We evaluated changes in anterior chamber (AC) morphology and iris volume induced by physiological mydriasis in fellow eyes of acute angle-closure patients, and age-, sex-, and central AC depth-matched primary angle-closure suspects (PACS).
METHODS: In our study, 21 fellow eyes of patients with acute angle closure; 40 age-, sex-, and central AC depth-matched PACS eyes; and 40 age- and sex-matched normal open-angle eyes were imaged using a Pentacam and anterior segment optical coherence tomography (AS-OCT) under light conditions, and after 5 minutes of darkness using AS-OCT. Iris volume was estimated using AS-OCT and a customized image-processing software.
RESULTS: Central AC depth, corneal curvature, axial length, and lens thickness did not differ significantly between the PACS and fellow eyes. When going from light to dark, angle opening distance at 500 μm decreased significantly more in fellow eyes than in PACS (-68% vs. -52%, P < 0.001). When going from light to dark, the mean iris volume increased significantly in the fellow eyes (from 45.34 ± 2.1 to 47.68 ± 3.2 mm(3), P < 0.01), whereas it decreased significantly in most PACS eyes (from 45.01 ± 2.2 to 42.11 ± 2.3 mm(3), P < 0.01), and in all open-angle eyes (from 44.68 ± 1.16 to 41.67 ± 1.20 mm(3), P < 0.01). Based on multivariate analysis, significant predictors of angle narrowing under darkness (relative change in angle-opening distance 500) were fellow eyes compared to PACS (β = -2.98, SE = 0.249, P = 0.005) and higher iris volume increase with pupil dilation (β = -3.146, SE = 0.432, P = 0.015).
CONCLUSIONS: Under dark conditions, angles of fellow eyes closed dramatically more than did those of PACS. Iris volume increase per millimeter of pupil dilation is an independent predictor of angle narrowing in darkness.

Entities:  

Mesh:

Year:  2012        PMID: 22618594     DOI: 10.1167/iovs.11-9387

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects.

Authors:  Jing-Min Guo; Mu Li; Xiao-Lan Xu; Hong Zhang; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Determinants of pupil diameters and pupil dynamics in an adult Chinese population.

Authors:  Ce Zheng; John Mark S de Leon; Carol Y Cheung; Arun K Narayanaswamy; Sim-Heng Ong; Clement W Tan; Paul T Chew; Shamira A Perera; Tien Y Wong; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-01-25       Impact factor: 3.117

3.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

4.  Comparison of dynamic changes in anterior ocular structures examined with anterior segment optical coherence tomography in a cohort of various origins.

Authors:  Fiona E Seager; Joan L Jefferys; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-19       Impact factor: 4.799

5.  Anterior Segment Optical Coherence Tomography: Applications for Clinical Care and Scientific Research.

Authors:  Jing Shan; Charles DeBoer; Benjamin Y Xu
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019-04-25

6.  Ocular Biometric Determinants of Dark-to-Light Change in Angle Width: The Chinese American Eye Study.

Authors:  Jacob Lifton; Bruce Burkemper; Xuejuan Jiang; Anmol A Pardeshi; Grace Richter; Roberta McKean-Cowdin; Rohit Varma; Benjamin Y Xu
Journal:  Am J Ophthalmol       Date:  2021-11-02       Impact factor: 5.488

7.  Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters.

Authors:  Benjamin Y Xu; Rafaella C Penteado; Robert N Weinreb
Journal:  J Glaucoma       Date:  2018-01       Impact factor: 2.503

8.  Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography.

Authors:  Anna I Dastiridou; Xiaojing Pan; ZhouYuan Zhang; Kenneth M Marion; Brian A Francis; Srinivas R Sadda; Vikas Chopra
Journal:  J Ophthalmol       Date:  2015-03-23       Impact factor: 1.909

9.  Associated factors of acute primary angle closure glaucoma in a sub-group of Chinese people: comparison between attack eyes and normal controls.

Authors:  Lifang Liu; Xinyu Liu; Chukai Huang; Geng Wang; Di Ma; Wanqi Zhang; Ce Zheng; Mingzhi Zhang
Journal:  Sci Rep       Date:  2017-11-02       Impact factor: 4.379

Review 10.  Ageing and ocular surface immunity.

Authors:  Alireza Mashaghi; Jiaxu Hong; Sunil K Chauhan; Reza Dana
Journal:  Br J Ophthalmol       Date:  2016-07-04       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.