Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters.

Benjamin Y Xu1,2, Rafaella C Penteado1, Robert N Weinreb1.   

Abstract

PURPOSE: To examine the diurnal variation of static and dynamic anterior segment parameters in young, healthy eyes by comparing anterior segment optical coherence tomography (AS-OCT) measurements obtained in the morning and evening and also in the light and dark.
METHODS: Twenty-two subjects ranging from 19 to 47 years of age with no past ocular history were selected. Imaging was performed with the Tomey CASIA2 AS-OCT device in 2 fixed lighting environments, light and dark, between the hours of 08:30 to 10:00 and 17:30 to 19:00. Four AS-OCT images were analyzed per eye. Pupil diameter (PD), iris area (IA), iris curvature (IC), anterior chamber depth (ACD), lens vault (LV), anterior chamber width (ACW), anterior chamber area (ACA), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were measured.
RESULTS: Pupil diameter was similar between the AM and PM groups in the light (P=0.89) and dark (P=0.51). There was no significant difference between AM and PM measurement values for any of the static or dynamic parameters in the light (P>0.39) and dark (P>0.31). Intraclass correlation coefficients (ICC) demonstrated excellent agreement between AM and PM measurement values in the light (ICC>0.81) and dark (ICC>0.93). In addition, there was no significant difference between AM and PM angle opening distance at 500 µm measurement values in the light (P>0.34) and dark (P>0.40) when each of 8 angle sectors was analyzed individually.
CONCLUSIONS: No significant diurnal variation of static or dynamic anterior segment parameter measurements was detected in the light and dark. Diurnal variation of these parameters does not regularly occur in young, healthy eyes.

Entities:  

Mesh:

Year:  2018        PMID: 29194197      PMCID: PMC5741520          DOI: 10.1097/IJG.0000000000000832

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  30 in total

1.  Diurnal variation of choroidal thickness in normal, healthy subjects measured by spectral domain optical coherence tomography.

Authors:  Colin S Tan; Yanling Ouyang; Humberto Ruiz; SriniVas R Sadda
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-25       Impact factor: 4.799

2.  Circadian variation of aqueous humor dynamics in older healthy adults.

Authors:  Cherie B Nau; Mehrdad Malihi; Jay W McLaren; David O Hodge; Arthur J Sit
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-15       Impact factor: 4.799

3.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

4.  Anterior segment biometry using spectral-domain optical coherence tomography.

Authors:  Florent Aptel; Christophe Chiquet; Aurélie Gimbert; Jean-Paul Romanet; Gilles Thuret; Philippe Gain; Nelly Campolmi
Journal:  J Refract Surg       Date:  2014-04-02       Impact factor: 3.573

Review 5.  Angle closure glaucoma: a mechanistic review.

Authors:  Monisha E Nongpiur; Judy Y F Ku; Tin Aung
Journal:  Curr Opin Ophthalmol       Date:  2011-03       Impact factor: 3.761

6.  Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations.

Authors:  Tin Aung; Winifred P Nolan; David Machin; Steve K L Seah; Jamyanjav Baasanhu; Peng T Khaw; Gordon J Johnson; Paul J Foster
Journal:  Arch Ophthalmol       Date:  2005-04

7.  Acute closed angle glaucoma and sunshine.

Authors:  J M Teikari; J O'Donnell; M Nurminen; I Raivio
Journal:  J Epidemiol Community Health       Date:  1991-12       Impact factor: 3.710

8.  Dynamic Iris Changes as a Risk Factor in Primary Angle Closure Disease.

Authors:  Ye Zhang; Si Zhen Li; Lei Li; Ming Guang He; Ravi Thomas; Ning Li Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-01-01       Impact factor: 4.799

9.  Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics.

Authors:  Handan Akil; Anna Dastiridou; Kenneth Marion; Brian A Francis; Vikas Chopra
Journal:  BMC Ophthalmol       Date:  2017-03-23       Impact factor: 2.209

10.  Reproducibility of scleral spur identification and angle measurements using fourier domain anterior segment optical coherence tomography.

Authors:  Ricardo J Cumba; Sunita Radhakrishnan; Nicholas P Bell; Kundandeep S Nagi; Alice Z Chuang; Shan C Lin; Kimberly A Mankiewicz; Robert M Feldman
Journal:  J Ophthalmol       Date:  2012-11-01       Impact factor: 1.909

View more
  4 in total

1.  Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness.

Authors:  Xuepei Li; Yijing Zhou; Charlotte Aimee Young; Aiming Chen; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2020-07

2.  Ocular Biometric Determinants of Dark-to-Light Change in Angle Width: The Chinese American Eye Study.

Authors:  Jacob Lifton; Bruce Burkemper; Xuejuan Jiang; Anmol A Pardeshi; Grace Richter; Roberta McKean-Cowdin; Rohit Varma; Benjamin Y Xu
Journal:  Am J Ophthalmol       Date:  2021-11-02       Impact factor: 5.488

3.  Differences in Anterior Chamber Angle Assessments Between Gonioscopy, EyeCam, and Anterior Segment OCT: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Anmol A Pardeshi; Bruce Burkemper; Grace M Richter; Shan C Lin; Roberta McKean-Cowdin; Rohit Varma
Journal:  Transl Vis Sci Technol       Date:  2019-03-26       Impact factor: 3.283

4.  Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT.

Authors:  Pedro Tañá-Rivero; Ramón Ruiz-Mesa; Salvador Aguilar-Córcoles; Cristina Tello-Elordi; María Ramos-Alzamora; Robert Montés-Micó
Journal:  J Optom       Date:  2021-11-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.