Literature DB >> 22575319

Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis.

Jennifer L Dorosz1, Dennis C Lezotte, David A Weitzenkamp, Larry A Allen, Ernesto E Salcedo.   

Abstract

OBJECTIVES: The primary aim of this systematic review is to objectively evaluate the test performance characteristics of three-dimensional echocardiography (3DE) in measuring left ventricular (LV) volumes and ejection fraction (EF).
BACKGROUND: Despite its growing use in clinical laboratories, the accuracy of 3DE has not been studied on a large scale. It is unclear if this technology offers an advantage over traditional two-dimensional (2D) methods.
METHODS: We searched for studies that compared LV volumes and EF measured by 3DE and cardiac magnetic resonance (CMR) imaging. A subset of those also compared standard 2D methods with CMR. We used meta-analyses to determine the overall bias and limits of agreement of LV end-diastolic volume (EDV), end-systolic volume (ESV), and EF measured by 3DE and 2D echocardiography (2DE).
RESULTS: Twenty-three studies (1,638 echocardiograms) were included. The pooled biases ± 2 SDs for 3DE were -19.1 ± 34.2 ml, -10.1 ± 29.7 ml, and - 0.6 ± 11.8% for EDV, ESV, and EF, respectively. Nine studies also included data from 2DE, where the pooled biases were -48.2 ± 55.9 ml, -27.7 ± 45.7 ml, and 0.1 ± 13.9% for EDV, ESV, and EF, respectively. In this subset, the difference in bias between 3DE and 2D volumes was statistically significant (p = 0.01 for both EDV and ESV). The difference in variance was statistically significant (p < 0.001) for all 3 measurements.
CONCLUSIONS: Three-dimensional echocardiography underestimates volumes and has wide limits of agreement, but compared with traditional 2D methods in these carefully performed studies, 3DE is more accurate for volumes and more precise in all 3 measurements.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22575319      PMCID: PMC3773600          DOI: 10.1016/j.jacc.2012.01.037

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  34 in total

1.  Live/real time three-dimensional transthoracic echocardiographic assessment of left ventricular volumes, ejection fraction, and mass compared with magnetic resonance imaging.

Authors:  Xin Qi; Bryan Cogar; Ming Chon Hsiung; Navin C Nanda; Andrew P Miller; Pridhvi Yelamanchili; Oben Baysan; Yu Shu Wu; Gong Yau Lan; James S Ko; Charles H Cheng; Chang Chyi Lin; Chien Ming Huang; Wei Hsian Yin; Mason Shing Young
Journal:  Echocardiography       Date:  2007-02       Impact factor: 1.724

2.  2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce W Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Rick A Nishimura; Blase A Carabello; David P Faxon; Michael D Freed; Bruce W Lytle; Patrick T O'Gara; Robert A O'Rourke; Pravin M Shah
Journal:  J Am Coll Cardiol       Date:  2008-09-23       Impact factor: 24.094

3.  Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters.

Authors:  Carly Jenkins; Jonathan Chan; Lizelle Hanekom; Thomas H Marwick
Journal:  J Am Soc Echocardiogr       Date:  2006-09       Impact factor: 5.251

4.  Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: insights from three-dimensional echocardiography and cardiac magnetic resonance imaging.

Authors:  Ebere O Chukwu; Eddy Barasch; Dennis G Mihalatos; Alan Katz; Justine Lachmann; Jing Han; Nathaniel Reichek; Aasha S Gopal
Journal:  J Am Soc Echocardiogr       Date:  2008-09       Impact factor: 5.251

5.  A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes.

Authors:  Osama I I Soliman; Boudewijn J Krenning; Marcel L Geleijnse; Attila Nemes; Robert-Jan van Geuns; Timo Baks; Ashraf M Anwar; Tjebbe W Galema; Wim B Vletter; Folkert J ten Cate
Journal:  Echocardiography       Date:  2007-10       Impact factor: 1.724

6.  Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: comparison with two-dimensional echocardiography and magnetic resonance imaging.

Authors:  Letícia S Bicudo; Jeane M Tsutsui; Afonso Shiozaki; Carlos E Rochitte; Edmundo Arteaga; Charles Mady; José A F Ramires; Wilson Mathias
Journal:  Echocardiography       Date:  2008-04-27       Impact factor: 1.724

7.  Quantification of left ventricular volumes and function in patients with cardiomyopathies by real-time three-dimensional echocardiography: a head-to-head comparison between two different semiautomated endocardial border detection algorithms.

Authors:  Osama I I Soliman; Boudewijn J Krenning; Marcel L Geleijnse; Attila Nemes; Johan G Bosch; Robert-Jan van Geuns; Sharon W Kirschbaum; Ashraf M Anwar; Tjebbe W Galema; Wim B Vletter; Folkert J ten Cate
Journal:  J Am Soc Echocardiogr       Date:  2007-06-12       Impact factor: 5.251

8.  Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging.

Authors:  Carly Jenkins; Rodel Leano; Jonathan Chan; Thomas H Marwick
Journal:  J Am Soc Echocardiogr       Date:  2007-07       Impact factor: 5.251

9.  Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance.

Authors:  Osama I I Soliman; Sharon W Kirschbaum; Bas M van Dalen; Heleen B van der Zwaan; Babak Mahdavian Delavary; Wim B Vletter; Robert-Jan M van Geuns; Folkert J Ten Cate; Marcel L Geleijnse
Journal:  Am J Cardiol       Date:  2008-07-09       Impact factor: 2.778

10.  Assessment of left ventricular mass and volumes by three-dimensional echocardiography in patients with or without wall motion abnormalities: comparison against cine magnetic resonance imaging.

Authors:  A-C Pouleur; J-B le Polain de Waroux; A Pasquet; B L Gerber; O Gérard; P Allain; J-L J Vanoverschelde
Journal:  Heart       Date:  2007-11-01       Impact factor: 5.994

View more
  85 in total

Review 1.  Echocardiographic assessment of left ventricular systolic function: from ejection fraction to torsion.

Authors:  Matteo Cameli; Sergio Mondillo; Marco Solari; Francesca Maria Righini; Valentina Andrei; Carla Contaldi; Eugenia De Marco; Michele Di Mauro; Roberta Esposito; Sabina Gallina; Roberta Montisci; Andrea Rossi; Maurizio Galderisi; Stefano Nistri; Eustachio Agricola; Donato Mele
Journal:  Heart Fail Rev       Date:  2016-01       Impact factor: 4.214

2.  Role of cardiovascular imaging in selection of donor hearts.

Authors:  Nandini Nair; Enrique Gongora
Journal:  World J Transplant       Date:  2015-12-24

3.  Single-beat real-time three-dimensional echocardiographic automated contour detection for quantification of left ventricular volumes and systolic function.

Authors:  Ben Ren; Wim B Vletter; Jackie McGhie; Osama I I Soliman; Marcel L Geleijnse
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-13       Impact factor: 2.357

Review 4.  Cardiotoxicity due to chemotherapy: role of cardiac imaging.

Authors:  Frédéric Poulin; Paaladinesh Thavendiranathan
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

5.  Real-time three-dimensional left ventricular contraction in patients with diastolic dysfunction.

Authors:  Suzan Hatipoğlu; Gamze Babur Güler; Özgür Kaya; Gökhan Kahveci; Ekrem Güler; Elif Eroğlu; Nihal Özdemir
Journal:  J Med Ultrason (2001)       Date:  2016-04-06       Impact factor: 1.314

6.  Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study.

Authors:  Seisyou Kou; Luis Caballero; Raluca Dulgheru; Damien Voilliot; Carla De Sousa; George Kacharava; George D Athanassopoulos; Daniele Barone; Monica Baroni; Nuno Cardim; Jose Juan Gomez De Diego; Andreas Hagendorff; Christine Henri; Krasimira Hristova; Teresa Lopez; Julien Magne; Gonzalo De La Morena; Bogdan A Popescu; Martin Penicka; Tolga Ozyigit; Jose David Rodrigo Carbonero; Alessandro Salustri; Nico Van De Veire; Ralph Stephan Von Bardeleben; Dragos Vinereanu; Jens-Uwe Voigt; Jose Luis Zamorano; Erwan Donal; Roberto M Lang; Luigi P Badano; Patrizio Lancellotti
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-01-21       Impact factor: 6.875

7.  Semiautomated biventricular segmentation in three-dimensional echocardiography by coupled deformable surfaces.

Authors:  Jørn Bersvendsen; Fredrik Orderud; Øyvind Lie; Richard John Massey; Kristian Fosså; Raúl San José Estépar; Stig Urheim; Eigil Samset
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-24

8.  Hcc-1 is a novel component of the nuclear matrix with growth inhibitory function.

Authors:  C L Leaw; E C Ren; M L Choong
Journal:  Cell Mol Life Sci       Date:  2004-09       Impact factor: 9.261

9.  Left atrial size and function in a South Asian population and their potential influence on the risk of atrial fibrillation.

Authors:  James O'Neill; Peter P Swoboda; Sven Plein; Muzahir H Tayebjee
Journal:  Clin Cardiol       Date:  2018-10-21       Impact factor: 2.882

Review 10.  Current Clinical Applications of Three-Dimensional Echocardiography: When the Technique Makes the Difference.

Authors:  Elena Surkova; Denisa Muraru; Patrizia Aruta; Gabriella Romeo; Jurate Bidviene; Diana Cherata; Luigi P Badano
Journal:  Curr Cardiol Rep       Date:  2016-11       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.