Literature DB >> 17894576

A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes.

Osama I I Soliman1, Boudewijn J Krenning, Marcel L Geleijnse, Attila Nemes, Robert-Jan van Geuns, Timo Baks, Ashraf M Anwar, Tjebbe W Galema, Wim B Vletter, Folkert J ten Cate.   

Abstract

OBJECTIVES: To compare the interobserver variability and accuracy of two different real time three-dimensional echocardiography (RT3DE) analyzing programs.
METHODS: Forty-one patients (mean age 56 +/- 11 years, 28 men) in sinus rhythm with a cardiomyopathy and adequate 2D image quality underwent RT3DE and magnetic resonance imaging (MRI) within one day. Off-line left ventricular (LV) volume analysis was performed with QLAB V4.2 (semiautomated border detection with biplane projections) and TomTec 4D LV analysis V2.0 (primarily manual tracking with triplane projections and semiautomated border detection).
RESULTS: Excellent correlations (R(2) > 0.98) were found between MRI and RT3DE. Bland-Altman analysis revealed an underestimated LV end-diastolic volume (LV-EDV) for both TomTec (-9.4 +/- 8.7 mL) and QLAB (-16.4 +/- 13.1 ml). Also, an underestimated LV end-systolic volume (LV-ESV) for both TomTec (-4.8 +/- 9.9 mL) and QLAB (-8.5 +/- 14.2 mL) was found. LV-EDV and LV-ESV were significantly more underestimated with QLAB software. Both programs accurately calculated LV ejection fraction (LV-EF) without a bias. Interobserver variability was 6.4 +/- 7.8% vs. 12.2 +/- 10.1% for LV-EDV, 7.8 +/- 9.7% vs. 13.6 +/- 11.2% for LV-ESV, and 7.1 +/- 6.9% vs. 9.7 +/- 8.8% for LV-EF for TomTec vs. QLAB, respectively. The analysis time was shorter with QLAB (4 +/- 2 minutes vs. 6 +/- 2 minutes, P < 0.05).
CONCLUSIONS: RT3DE with TomTec or QLAB software analysis provides accurate LV-EF assessment in cardiomyopathic patients with distorted LV geometry and adequate 2D image quality. However, LV volumes may be somewhat more underestimated with the current QLAB software version.

Entities:  

Mesh:

Year:  2007        PMID: 17894576     DOI: 10.1111/j.1540-8175.2007.00502.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  20 in total

Review 1.  Echocardiography in pericardial diseases: new developments.

Authors:  Gabriella Veress; Dali Feng; Jae K Oh
Journal:  Heart Fail Rev       Date:  2013-05       Impact factor: 4.214

2.  Single-beat real-time three-dimensional echocardiographic automated contour detection for quantification of left ventricular volumes and systolic function.

Authors:  Ben Ren; Wim B Vletter; Jackie McGhie; Osama I I Soliman; Marcel L Geleijnse
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-13       Impact factor: 2.357

3.  Effect of ultrasound-assisted freezing on the textural characteristics of dough and the structural characterization of wheat gluten.

Authors:  Yinli Li; Yanyan Zhang; Xingli Liu; Hongwei Wang; Hua Zhang
Journal:  J Food Sci Technol       Date:  2019-06-08       Impact factor: 2.701

4.  Quantification of left ventricular volume and global function using a fast automated segmentation tool: validation in a clinical setting.

Authors:  Daniel Barbosa; Brecht Heyde; Thomas Dietenbeck; Helene Houle; Denis Friboulet; Olivier Bernard; Jan D'hooge
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-01       Impact factor: 2.357

Review 5.  [Artificial intelligence in cardiac surgery].

Authors:  M Cypko; M Y Emmert; V Falk; A Meyer
Journal:  Chirurg       Date:  2020-03       Impact factor: 0.955

6.  TNF-α, myocardial perfusion and function in patients with ST-segment elevation myocardial infarction and primary percutaneous coronary intervention.

Authors:  Eva S Kehmeier; Wolfgang Lepper; Martina Kropp; Christian Heiss; Ulrike Hendgen-Cotta; Jan Balzer; Mirja Neizel; Christian Meyer; Marc W Merx; Pablo E Verde; Christian Ohmann; Gerd Heusch; Malte Kelm; Tienush Rassaf
Journal:  Clin Res Cardiol       Date:  2012-05-06       Impact factor: 5.460

Review 7.  Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis.

Authors:  Jennifer L Dorosz; Dennis C Lezotte; David A Weitzenkamp; Larry A Allen; Ernesto E Salcedo
Journal:  J Am Coll Cardiol       Date:  2012-05-15       Impact factor: 24.094

8.  Three-dimensional echocardiography for left ventricular quantification: fundamental validation and clinical applications.

Authors:  J A van der Heide; S A Kleijn; M F A Aly; J Slikkerveer; O Kamp
Journal:  Neth Heart J       Date:  2011-10       Impact factor: 2.380

9.  Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography.

Authors:  Jøger Hansegård; Stig Urheim; Ketil Lunde; Siri Malm; Stein Inge Rabben
Journal:  Cardiovasc Ultrasound       Date:  2009-04-20       Impact factor: 2.062

10.  Automated quantification of left atrial size using three-beat averaging real-time three dimensional Echocardiography in patients with atrial fibrillation.

Authors:  Ran Heo; Geu-Ru Hong; Young-Jin Kim; Joel Mancina; In-Jeong Cho; Chi Young Shim; Hyuk-Jae Chang; Jong-Won Ha; Namsik Chung
Journal:  Cardiovasc Ultrasound       Date:  2015-08-25       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.