Literature DB >> 24221906

Single-beat real-time three-dimensional echocardiographic automated contour detection for quantification of left ventricular volumes and systolic function.

Ben Ren1, Wim B Vletter, Jackie McGhie, Osama I I Soliman, Marcel L Geleijnse.   

Abstract

To assess the feasibility and accuracy in measuring left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) with Siemens single-beat real-time 3D transthoracic echocardiography. The LV volumes and EF were measured in 3D datasets acquired by six imaging modes (time-1-harmonic (T1H), time-1-fundamental, time-2-harmonic, time-2-fundamental, space-1-harmonic (S1H), and space-1-fundamental) in 41 patients using the automated contouring algorithm and compared with manually corrected 3DE QLAB measurements. The main determinates of the temporal and spatial resolutions of 3D datasets acquired were the fundamental and harmonic modes. Consequently, the S1H mode had the lowest volume rate and highest spatial resolution. Compared with the 3DE QLAB analysis, the S1H mode resulted in the best LV volumes and EF estimates in all patients (0 ± 10 % for EF, -7 ± 44 ml for EDV, -7 ± 39 ml for ESV) and in the 10 patients with correct LV contour tracking according to a visual assessment from the multiplanar reconstruction views in all six modes (0 ± 9 % for EF, -3 ± 23 ml for EDV, -2 ± 14 ml for ESV). The T1H mode was the best alternative. Overall 28 patients (68 %) could be analysed automatically and satisfyingly with the S1H and T1H modes: 0 ± 8 % (EF), 0 ± 27 ml (EDV) and -1 ± 16 ml (ESV). The accuracy of the Siemens automated RT-3D algorithm in measuring LV volumes and EF is significantly influenced by the different imaging modes. The S1H mode may be the preferred 3D acquisition mode, supplemented by the T1H mode in enlarged LVs that do not fit in the S1H acquisition sector.

Entities:  

Mesh:

Year:  2013        PMID: 24221906     DOI: 10.1007/s10554-013-0327-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  15 in total

1.  Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function.

Authors:  Boudewijn J Krenning; Sharon W Kirschbaum; Osama I I Soliman; Attila Nemes; Robert-Jan van Geuns; Wim B Vletter; Caroline E Veltman; Folkert J Ten Cate; Jos R T C Roelandt; Marcel L Geleijnse
Journal:  Am J Cardiol       Date:  2007-08-24       Impact factor: 2.778

2.  Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error.

Authors:  Victor Mor-Avi; Carly Jenkins; Harald P Kühl; Hans-Joachim Nesser; Thomas Marwick; Andreas Franke; Christian Ebner; Benjamin H Freed; Regina Steringer-Mascherbauer; Heidi Pollard; Lynn Weinert; Johannes Niel; Lissa Sugeng; Roberto M Lang
Journal:  JACC Cardiovasc Imaging       Date:  2008-07

3.  Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography.

Authors:  Denisa Muraru; Luigi P Badano; Gianluca Piccoli; Pasquale Gianfagna; Lorenzo Del Mestre; Davide Ermacora; Alessandro Proclemer
Journal:  Eur J Echocardiogr       Date:  2009-12-30

4.  Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation.

Authors:  Paaladinesh Thavendiranathan; Shizhen Liu; David Verhaert; Anna Calleja; Adrien Nitinunu; Thomas Van Houten; Nathalie De Michelis; Orlando Simonetti; Sanjay Rajagopalan; Thomas Ryan; Mani A Vannan
Journal:  JACC Cardiovasc Imaging       Date:  2012-03

5.  Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: a prospective, randomly assigned, blinded study.

Authors:  H L Thomson; A J Basmadjian; A J Rainbird; M Razavi; J F Avierinos; P A Pellikka; K R Bailey; J F Breen; M Enriquez-Sarano
Journal:  J Am Coll Cardiol       Date:  2001-09       Impact factor: 24.094

6.  Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography.

Authors:  Carly Jenkins; Kristen Bricknell; Lizelle Hanekom; Thomas H Marwick
Journal:  J Am Coll Cardiol       Date:  2004-08-18       Impact factor: 24.094

7.  Natural history of asymptomatic left ventricular systolic dysfunction in the community.

Authors:  Thomas J Wang; Jane C Evans; Emelia J Benjamin; Daniel Levy; Elizabeth C LeRoy; Ramachandran S Vasan
Journal:  Circulation       Date:  2003-08-11       Impact factor: 29.690

8.  Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.

Authors:  H D White; R M Norris; M A Brown; P W Brandt; R M Whitlock; C J Wild
Journal:  Circulation       Date:  1987-07       Impact factor: 29.690

9.  A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes.

Authors:  Osama I I Soliman; Boudewijn J Krenning; Marcel L Geleijnse; Attila Nemes; Robert-Jan van Geuns; Timo Baks; Ashraf M Anwar; Tjebbe W Galema; Wim B Vletter; Folkert J ten Cate
Journal:  Echocardiography       Date:  2007-10       Impact factor: 1.724

Review 10.  Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis.

Authors:  Jennifer L Dorosz; Dennis C Lezotte; David A Weitzenkamp; Larry A Allen; Ernesto E Salcedo
Journal:  J Am Coll Cardiol       Date:  2012-05-15       Impact factor: 24.094

View more
  2 in total

1.  Evaluation of right ventricular function using single-beat three-dimensional echocardiography in neonate.

Authors:  Kazuhiro Watanabe; Ikuo Hashimoto; Keijiro Ibuki; Mako Okabe; Hisashi Kaneda; Fukiko Ichida
Journal:  Pediatr Cardiol       Date:  2015-01-15       Impact factor: 1.655

2.  The Role of Automated 3D Echocardiography for Left Ventricular Ejection Fraction Assessment.

Authors:  Ernest Spitzer; Ben Ren; Felix Zijlstra; Nicolas M Van Mieghem; Marcel L Geleijnse
Journal:  Card Fail Rev       Date:  2017-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.