Prospective motion correction using tracking coils.

Lei Qin1, Ehud J Schmidt, Zion Tsz Ho Tse, Juan Santos, William S Hoge, Clare Tempany-Afdhal, Kim Butts-Pauly, Charles L Dumoulin.   

Abstract

Intracavity imaging coils provide higher signal-to-noise than surface coils and have the potential to provide higher spatial resolution in shorter acquisition times. However, images from these coils suffer from physiologically induced motion artifacts, as both the anatomy and the coils move during image acquisition. We developed prospective motion-correction techniques for intracavity imaging using an array of tracking coils. The system had <50 ms latency between tracking and imaging, so that the images from the intracavity coil were acquired in a frame of reference defined by the tracking array rather than by the system's gradient coils. Two-dimensional gradient-recalled and three-dimensional electrocardiogram-gated inversion-recovery-fast-gradient-echo sequences were tested with prospective motion correction using ex vivo hearts placed on a moving platform simulating both respiratory and cardiac motion. Human abdominal tests were subsequently conducted. The tracking array provided a positional accuracy of 0.7 ± 0.5 mm, 0.6 ± 0.4 mm, and 0.1 ± 0.1 mm along the X, Y, and Z directions at a rate of 20 frames-per-second. The ex vivo and human experiments showed significant image quality improvements for both in-plane and through-plane motion correction, which although not performed in intracavity imaging, demonstrates the feasibility of implementing such a motion-correction system in a future design of combined tracking and intracavity coil.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22565377      PMCID: PMC3416927          DOI: 10.1002/mrm.24310

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Phase-field dithering for active catheter tracking.

Authors:  Charles L Dumoulin; Richard P Mallozzi; Robert D Darrow; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

2.  Magnetic resonance imaging of the uterine cervix using an intravaginal coil.

Authors:  C J Baudouin; W P Soutter; D J Gilderdale; G A Coutts
Journal:  Magn Reson Med       Date:  1992-03       Impact factor: 4.668

3.  Flexible real-time magnetic resonance imaging framework.

Authors:  Juan M Santos; Graham A Wright; John M Pauly
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

4.  Real-time rigid body motion correction and shimming using cloverleaf navigators.

Authors:  André J W van der Kouwe; Thomas Benner; Anders M Dale
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

5.  3D coronary motion tracking in swine models with MR tracking catheters.

Authors:  Ehud J Schmidt; Ryuichi Yoneyama; Charles L Dumoulin; Robert D Darrow; Eric Klein; Andrew J M Kiruluta; Motoya Hayase
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

6.  An expandable catheter loop coil for intravascular MRI in larger blood vessels.

Authors:  Ann-Kathrin Homagk; Reiner Umathum; Matthias Korn; Marc-André Weber; Peter Hallscheidt; Wolfhard Semmler; Michael Bock
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

7.  Role of endorectal coil magnetic resonance imaging in treatment of patients with prostate cancer and in determining radical prostatectomy surgical margin status: report of a single surgeon's practice.

Authors:  Jian Qing Zhang; Kevin R Loughlin; Kelly H Zou; Steven Haker; Clare M C Tempany
Journal:  Urology       Date:  2007-06       Impact factor: 2.649

8.  Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine.

Authors:  Alexander J Dick; Michael A Guttman; Venkatesh K Raman; Dana C Peters; Breno S S Pessanha; Jonathan M Hill; Scott Smith; Greig Scott; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2003-12-01       Impact factor: 29.690

9.  Electroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking.

Authors:  Ehud J Schmidt; Richard P Mallozzi; Aravinda Thiagalingam; Godtfred Holmvang; Andre d'Avila; Renee Guhde; Robert Darrow; Glenn S Slavin; Maggie M Fung; Jeremy Dando; Lori Foley; Charles L Dumoulin; Vivek Y Reddy
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

10.  Prospective real-time correction for arbitrary head motion using active markers.

Authors:  Melvyn B Ooi; Sascha Krueger; William J Thomas; Srirama V Swaminathan; Truman R Brown
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

View more
  11 in total

1.  An MR-conditional high-torque pneumatic stepper motor for MRI-guided and robot-assisted intervention.

Authors:  Yue Chen; Ka-Wai Kwok; Zion Tsz Ho Tse
Journal:  Ann Biomed Eng       Date:  2014-06-24       Impact factor: 3.934

2.  Bayesian framework inspired no-reference region-of-interest quality measure for brain MRI images.

Authors:  Michael Osadebey; Marius Pedersen; Douglas Arnold; Katrina Wendel-Mitoraj
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-13

3.  MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: phantom study.

Authors:  Chuan Huang; Jerome L Ackerman; Yoann Petibon; Thomas J Brady; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

4.  Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET-MR: phantom and non-human primate studies.

Authors:  Chuan Huang; Jerome L Ackerman; Yoann Petibon; Marc D Normandin; Thomas J Brady; Georges El Fakhri; Jinsong Ouyang
Journal:  Neuroimage       Date:  2014-01-10       Impact factor: 6.556

5.  Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil.

Authors:  Nelly A Volland; Eugene G Kholmovski; Dennis L Parker; J Rock Hadley
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

Review 6.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

7.  Statistical estimation of physiological brain age as a descriptor of senescence rate during adulthood.

Authors:  Andrei Irimia; Carinna M Torgerson; S-Y Matthew Goh; John D Van Horn
Journal:  Brain Imaging Behav       Date:  2015-12       Impact factor: 3.978

8.  Acceleration and motion-correction techniques for high-resolution intravascular MRI.

Authors:  Shashank Sathyanarayana Hegde; Yi Zhang; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2014-08-27       Impact factor: 4.668

9.  Prospective motion correction using inductively coupled wireless RF coils.

Authors:  Melvyn B Ooi; Murat Aksoy; Julian Maclaren; Ronald D Watkins; Roland Bammer
Journal:  Magn Reson Med       Date:  2013-06-27       Impact factor: 4.668

10.  Design and Fabrication of MR-Tracked Metallic Stylet for Gynecologic Brachytherapy.

Authors:  Yue Chen; Wei Wang; Ehud J Schmidt; Ka-Wai Kwok; Akila N Viswanathan; Robert Cormack; Zion Tsz Ho Tse
Journal:  IEEE ASME Trans Mechatron       Date:  2015-11-24       Impact factor: 5.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.