Phase-field dithering for active catheter tracking.

Charles L Dumoulin1, Richard P Mallozzi, Robert D Darrow, Ehud J Schmidt.   

Abstract

A strategy to increase the robustness of active MR tracking of microcoils in low signal-to-noise ratio conditions was developed and tested. The method employs dephasing magnetic field gradient pulses that are applied orthogonal to the frequency-encoding gradient pulse used in conventional point-source MR tracking. In subsequent acquisitions, the orthogonal dephasing gradient pulse is rotated while maintaining a perpendicular orientation with respect to the frequency-encoding gradient. The effect of the dephasing gradient is to apply a spatially dependent phase shift in directions perpendicular to the frequency-encoding gradient. Since the desired MR signal for robust MR tracking comes from the small volume of nuclear spins near the small detection coil, the desired signal is not dramatically altered by the dephasing gradient. Undesired MR signals arising from larger volumes (e.g., due to coupling with the body coil or surface coils), on the other hand, are dephased and reduced in signal intensity. Since the approach requires no a priori knowledge of the microcoil orientation with respect to the main magnetic field, data from several orthogonal dephasing gradients are acquired and analyzed in real time. One of several selection algorithms is employed to identify the "best" data for use in the coil localization algorithm. This approach was tested in flow phantoms and animal models, with several multiplexing schemes, including the Hadamard and zero-phase reference approaches. It was found to provide improved MR tracking of untuned microcoils. It also dramatically improved MR tracking robustness in low signal-to-noise-ratio conditions and permitted tracking of microcoils that were inductively coupled to the body coil. (c) 2010 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 20432311     DOI: 10.1002/mrm.22297

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  In vivo MR acoustic radiation force imaging in the porcine liver.

Authors:  Andrew B Holbrook; Pejman Ghanouni; Juan M Santos; Yoav Medan; Kim Butts Pauly
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Prospective motion correction using tracking coils.

Authors:  Lei Qin; Ehud J Schmidt; Zion Tsz Ho Tse; Juan Santos; William S Hoge; Clare Tempany-Afdhal; Kim Butts-Pauly; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2012-05-07       Impact factor: 4.668

3.  MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation.

Authors:  Akbar Alipour; Eric S Meyer; Charles L Dumoulin; Ronald D Watkins; Hassan Elahi; Wolfgang Loew; Jeffrey Schweitzer; Gregory Olson; Yue Chen; Susumu Tao; Michael Guttman; Aravindan Kolandaivelu; Henry R Halperin; Ehud J Schmidt
Journal:  IEEE Trans Biomed Eng       Date:  2019-09-13       Impact factor: 4.538

4.  Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases.

Authors:  Matthias Grothoff; Matthias Gutberlet; Gerhard Hindricks; Christian Fleiter; Bernhard Schnackenburg; Steffen Weiss; Sascha Krueger; Christopher Piorkowski; Thomas Gaspar; Steve Wedan; Thomas Lloyd; Philipp Sommer; Sebastian Hilbert
Journal:  Eur Radiol       Date:  2016-08-23       Impact factor: 5.315

5.  Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.

Authors:  Matthew S Adams; Vasant A Salgaonkar; Juan Plata-Camargo; Peter D Jones; Aurea Pascal-Tenorio; Hsin-Yu Chen; Donna M Bouley; Graham Sommer; Kim Butts Pauly; Chris J Diederich
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

Review 6.  MRI use for atrial tissue characterization in arrhythmias and for EP procedure guidance.

Authors:  Ehud J Schmidt; Henry R Halperin
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-07       Impact factor: 2.357

7.  Real-time active MR-tracking of metallic stylets in MR-guided radiation therapy.

Authors:  Wei Wang; Charles L Dumoulin; Akila N Viswanathan; Zion T H Tse; Alireza Mehrtash; Wolfgang Loew; Isaiah Norton; Junichi Tokuda; Ravi T Seethamraju; Tina Kapur; Antonio L Damato; Robert A Cormack; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-06-05       Impact factor: 4.668

8.  3-T MR-guided brachytherapy for gynecologic malignancies.

Authors:  Tina Kapur; Jan Egger; Antonio Damato; Ehud J Schmidt; Akila N Viswanathan
Journal:  Magn Reson Imaging       Date:  2012-08-13       Impact factor: 2.546

9.  Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Authors:  Ehud J Schmidt; Zion T H Tse; Tobias R Reichlin; Gregory F Michaud; Ronald D Watkins; Kim Butts-Pauly; Raymond Y Kwong; William Stevenson; Jeffrey Schweitzer; Israel Byrd; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

Authors:  Santhi Elayaperumal; Juan Camilo Plata; Andrew B Holbrook; Yong-Lae Park; Kim Butts Pauly; Bruce L Daniel; Mark R Cutkosky
Journal:  IEEE Trans Med Imaging       Date:  2014-06-23       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.