Literature DB >> 17029223

Real-time rigid body motion correction and shimming using cloverleaf navigators.

André J W van der Kouwe1, Thomas Benner, Anders M Dale.   

Abstract

Subject motion during scanning can greatly reduce MRI image quality and is a major reason for discarding data in both clinical and research scanning. The quality of the high-resolution structural data used for morphometric analysis is especially compromised by subject movement because high-resolution scans are of longer duration. A method is presented that measures and corrects rigid body motion and associated first-order shim changes in real time, using a pulse sequence with embedded cloverleaf navigators and a feedback control mechanism. The procedure requires a 12-s preliminary mapping scan. A single-path, 4.2-ms cloverleaf navigator is inserted every repetition time (TR) after the readout of a 3D fast low-angle shot (FLASH) sequence, requiring no additional RF pulses and minimally impacting scan duration. Every TR, a rigid body motion estimate is made and a correction is fed back to adjust the gradients and shim offsets. Images are corrected and reconstructed on the scanner computer for immediate access. Correction for between-scan motion can be accomplished by using the same reference map for each scan repetition. Human and phantom tests demonstrated a consistent improvement in image quality if motion occurred during the acquisition. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 17029223     DOI: 10.1002/mrm.21038

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  82 in total

1.  Entorhinal verrucae geometry is coincident and correlates with Alzheimer's lesions: a combined neuropathology and high-resolution ex vivo MRI analysis.

Authors:  Jean C Augustinack; Kristen E Huber; Gheorghe M Postelnicu; Sita Kakunoori; Ruopeng Wang; André J W van der Kouwe; Lawrence L Wald; Thor D Stein; Matthew P Frosch; Bruce Fischl
Journal:  Acta Neuropathol       Date:  2011-12-13       Impact factor: 17.088

2.  An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T.

Authors:  Jessica Schulz; Thomas Siegert; Enrico Reimer; Christian Labadie; Julian Maclaren; Michael Herbst; Maxim Zaitsev; Robert Turner
Journal:  MAGMA       Date:  2012-06-13       Impact factor: 2.310

3.  Nonrigid motion correction in 3D using autofocusing with localized linear translations.

Authors:  Joseph Y Cheng; Marcus T Alley; Charles H Cunningham; Shreyas S Vasanawala; John M Pauly; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-02-03       Impact factor: 4.668

4.  H.M.'s contributions to neuroscience: a review and autopsy studies.

Authors:  Jean C Augustinack; André J W van der Kouwe; David H Salat; Thomas Benner; Allison A Stevens; Jacopo Annese; Bruce Fischl; Matthew P Frosch; Suzanne Corkin
Journal:  Hippocampus       Date:  2014-09-23       Impact factor: 3.899

5.  Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs).

Authors:  Gizeaddis L Simegn; Andre J W Van der Kouwe; Frances C Robertson; Ernesta M Meintjes; Ali Alhamud
Journal:  Magn Reson Med       Date:  2018-12-02       Impact factor: 4.668

6.  MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

Authors:  Ciprian Catana; Thomas Benner; Andre van der Kouwe; Larry Byars; Michael Hamm; Daniel B Chonde; Christian J Michel; Georges El Fakhri; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2011-01       Impact factor: 10.057

7.  Event-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing.

Authors:  Fa-Hsuan Lin; Thomas Witzel; Joseph B Mandeville; Jonathan R Polimeni; Thomas A Zeffiro; Douglas N Greve; Graham Wiggins; Lawrence L Wald; John W Belliveau
Journal:  Neuroimage       Date:  2008-04-23       Impact factor: 6.556

8.  Prospective motion correction using tracking coils.

Authors:  Lei Qin; Ehud J Schmidt; Zion Tsz Ho Tse; Juan Santos; William S Hoge; Clare Tempany-Afdhal; Kim Butts-Pauly; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2012-05-07       Impact factor: 4.668

Review 9.  Motion-compensation techniques in neonatal and fetal MR imaging.

Authors:  C Malamateniou; S J Malik; S J Counsell; J M Allsop; A K McGuinness; T Hayat; K Broadhouse; R G Nunes; A M Ederies; J V Hajnal; M A Rutherford
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

10.  Prospective active marker motion correction improves statistical power in BOLD fMRI.

Authors:  Jordan Muraskin; Melvyn B Ooi; Robin I Goldman; Sascha Krueger; William J Thomas; Paul Sajda; Truman R Brown
Journal:  Neuroimage       Date:  2012-12-05       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.