Literature DB >> 22549104

Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential.

Ralph Gnannt1, Anna Winklehner, Daniel Eberli, Alexander Knuth, Thomas Frauenfelder, Hatem Alkadhi.   

Abstract

OBJECTIVE: To evaluate prospectively, in patients with testicular cancer, the radiation dose-saving potential and image quality of contrast-enhanced chest and abdominal CT with automated tube potential selection.
METHODS: Forty consecutive patients with testicular cancer underwent contrast-enhanced arterio-venous chest and portal-venous abdominal CT with automated tube potential selection (protocol B; tube potential 80-140 kVp), which is based on the attenuation of the CT topogram. All had a first CT at 120 kVp (protocol A) using the same 64-section CT machine and similar settings. Image quality was assessed; dose information (CTDI(vol)) was noted.
RESULTS: Image noise and attenuation in the liver and spleen were significantly higher for protocol B (P < 0.05 each), whereas attenuation in the deltoid and erector spinae muscles was similar. In protocol B, tube potential was reduced to 100 kVp in 18 chest and 33 abdominal examinations, and to 80 kVp in 5 abdominal CT examinations; it increased to 140 kVp in one patient. Image quality of examinations using both CT protocols was rated as diagnostic. CTDI(vol) was significantly lower for protocol B compared to protocol A (reduction by 12%, P < 0.01).
CONCLUSION: In patients with testicular cancer, radiation dose of chest and abdominal CT can be reduced with automated tube potential selection, while image quality is preserved.

Entities:  

Mesh:

Year:  2012        PMID: 22549104     DOI: 10.1007/s00330-012-2453-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol.

Authors:  R Gnannt; A Winklehner; R Goetti; B Schmidt; S Kollias; H Alkadhi
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

3.  Automatic selection of tube potential for radiation dose reduction in CT: a general strategy.

Authors:  Lifeng Yu; Hua Li; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Duo Liu; Takeshi Nakaura; Yoshitaka Tamura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2006-11       Impact factor: 3.959

5.  Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results.

Authors:  Daniele Marin; Rendon C Nelson; Huiman Barnhart; Sebastian T Schindera; Lisa M Ho; Tracy A Jaffe; Terry T Yoshizumi; Richard Youngblood; Ehsan Samei
Journal:  Radiology       Date:  2010-08       Impact factor: 11.105

Review 6.  Guidelines on testicular cancer.

Authors:  Peter Albers; Walter Albrecht; Ferran Algaba; Carsten Bokemeyer; Gabriella Cohn-Cedermark; Alan Horwich; Olbjoern Klepp; M Pilar Laguna; Giorgio Pizzocaro
Journal:  Eur Urol       Date:  2005-07-18       Impact factor: 20.096

Review 7.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

8.  Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

Authors:  David J Brenner; Richard Doll; Dudley T Goodhead; Eric J Hall; Charles E Land; John B Little; Jay H Lubin; Dale L Preston; R Julian Preston; Jerome S Puskin; Elaine Ron; Rainer K Sachs; Jonathan M Samet; Richard B Setlow; Marco Zaider
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-10       Impact factor: 11.205

9.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

10.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

View more
  9 in total

1.  Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction.

Authors:  So Won Lee; Yookyung Kim; Sung Shine Shim; Jeong Kyong Lee; Seok Jeong Lee; Yon Ju Ryu; Jung Hyun Chang
Journal:  Eur Radiol       Date:  2014-01-18       Impact factor: 5.315

2.  Clinical evaluation of automatic tube voltage selection in chest CT angiography.

Authors:  Tilo Niemann; Simon Henry; Jean-Baptiste Faivre; Kanna Yasunaga; Sofiane Bendaoud; Ariana Simeone; Jacques Remy; Alain Duhamel; Thomas Flohr; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2013-07-05       Impact factor: 5.315

3.  Radiation exposure from diagnostic imaging in young patients with testicular cancer.

Authors:  C J Sullivan; K P Murphy; P D McLaughlin; M Twomey; K N O'Regan; D G Power; M M Maher; O J O'Connor
Journal:  Eur Radiol       Date:  2014-12-13       Impact factor: 5.315

4.  Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.

Authors:  Clara Park; Tatjana Gruber-Rouh; Doris Leithner; Amelie Zierden; Mortiz H Albrecht; Julian L Wichmann; Boris Bodelle; Mohamed Elsabaie; Jan-Erik Scholtz; Moritz Kaup; Thomas J Vogl; Martin Beeres
Journal:  Cancer Imaging       Date:  2016-10-10       Impact factor: 3.909

5.  Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.

Authors:  Claudia Frellesen; Wenzel Stock; J Matthias Kerl; Thomas Lehnert; Julian L Wichmann; Christoph Nau; Emanuel Geiger; Sebastian Wutzler; Martin Beeres; Boris Schulz; Boris Bodelle; Hanns Ackermann; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

6.  Chest-abdomen-pelvis CT for staging in cancer patients: dose effectiveness and image quality using automated attenuation-based tube potential selection.

Authors:  Martin Beeres; Marcus Römer; Boris Bodelle; Clara Lee; Tatjana Gruber-Rouh; Emmanuel Mbalisike; Josef M Kerl; Julian L Wichmann; Boris Schulz; Thomas J Vogl; Ralf W Bauer
Journal:  Cancer Imaging       Date:  2014-09-02       Impact factor: 3.909

7.  Attenuation-based automatic kilovoltage selection and sinogram-affirmed iterative reconstruction: effects on radiation exposure and image quality of portal-phase liver CT.

Authors:  Ji Soo Song; Eun Jung Choi; Eun Young Kim; Hyo Sung Kwak; Young Min Han
Journal:  Korean J Radiol       Date:  2015-01-09       Impact factor: 3.500

8.  Can fully iterative reconstruction technique enable routine abdominal CT at less than 1 mSv?

Authors:  Azadeh Tabari; Singh Ramandeep; Ruhani Doda Khera; Yiemeng Hoi; Erin Angel; Mannudeep K Kalra; Rachna Madan
Journal:  Eur J Radiol Open       Date:  2019-06-21

9.  Feasibility of low-dose CT with model-based iterative image reconstruction in follow-up of patients with testicular cancer.

Authors:  Kevin P Murphy; Lee Crush; Siobhan B O'Neill; James Foody; Micheál Breen; Adrian Brady; Paul J Kelly; Derek G Power; Paul Sweeney; Jackie Bye; Owen J O'Connor; Michael M Maher; Kevin N O'Regan
Journal:  Eur J Radiol Open       Date:  2016-02-16
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.