Literature DB >> 22547125

[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

A Frings1, I Steinbrugger, E Wissiak, B Vidic, Y El-Shabrawi, N Ardjomand.   

Abstract

BACKGROUND: Based on previous data on single-piece and three-piece intraocular lenses (IOLs) there is no evidence for significant differences in decentration, tilt and refractive shift. The purpose of the current study was to compare single-piece and three-piece IOLs in patients with high axial myopia.
MATERIAL AND METHODS: A total of 68 eyes of 50 patients with high axial myopia (axis length ≥ 28.00 mm) with and without cataract who underwent complication-free phacoemulsification and IOL implantation were retrospectively examined. To compare single-piece and three-piece IOLs, the patients were retrospectively grouped depending on IOL type: group 1 acrylic single-piece IOL (n = 37; ACR6D SE, Corneal, France) and group 2 acrylic three-piece IOL with fixed haptic frame (n = 31; AF-1 UY, Hoya, Japan). Patient files were analyzed regarding best spectacle-corrected visual acuity (BSCVA), refractive predictability and stability.
RESULTS: In this study the mean BSCVA was determined as 0.22 ± 0.12 logMAR and 0.13 ± 0.11 logMAR 6 months postoperatively for the ACR6D SE group and the AF-1 UV group, respectively (p = 0.09). Refractive predictability was less accurate in the ACR6D SE (+ 1.75 ± 2.2 dpt) compared to the AF-1 UV (- 0.37 ± 1.1) treated eyes (p = 0.001). Refractive stability, defined as the difference in diopters between the first week and the sixth month after surgery, resulted in  + 0.40 ± 1.7 dpt and -0.16 ± 1.2 dpt for the ACR6D SE and the AF-1 UV, respectively (p = 0.022).
CONCLUSIONS: The three-piece AF-1 UV showed satisfactory refractive predictability and stability in patients with high axial myopia. The ACR6D SE has a high refractive unpredictability and should not be used in eyes with high axial myopia.

Entities:  

Mesh:

Year:  2012        PMID: 22547125     DOI: 10.1007/s00347-012-2556-5

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  20 in total

1.  Pseudophakic retinal detachment after phacoemulsification cataract surgery: Ten-year retrospective review.

Authors:  Matthew Russell; Brent Gaskin; Daniel Russell; Philip John Polkinghorne
Journal:  J Cataract Refract Surg       Date:  2006-03       Impact factor: 3.351

2.  Clinicopathologic correlation of capsulorhexis phimosis with anterior flexing of single-piece hydrophilic acrylic intraocular lens haptics.

Authors:  Brian Zaugg; Liliana Werner; Tobias Neuhann; Michael Burrow; Don Davis; Nick Mamalis; Manfred Tetz
Journal:  J Cataract Refract Surg       Date:  2010-09       Impact factor: 3.351

3.  Hyperopic shift from posterior migration of hydrophilic acrylic intraocular lens optic.

Authors:  Dania Qatarneh; Scott Hau; Stephen Tuft
Journal:  J Cataract Refract Surg       Date:  2010-01       Impact factor: 3.351

4.  Anterior segment parameters: comparison of 1-piece and 3-piece acrylic foldable intraocular lenses.

Authors:  Mahmoud Jabbarvand Behrouz; Ahmad Kheirkhah; Hesam Hashemian; Rahman Nazari
Journal:  J Cataract Refract Surg       Date:  2010-10       Impact factor: 3.351

5.  Intraocular lens calculation in extreme myopia.

Authors:  Wolfgang Haigis
Journal:  J Cataract Refract Surg       Date:  2009-05       Impact factor: 3.351

6.  Impact of intraocular lens haptic design and orientation on decentration and tilt.

Authors:  Alja Crnej; Nino Hirnschall; Yutaro Nishi; Vinod Gangwani; Juan Tabernero; Pablo Artal; Oliver Findl
Journal:  J Cataract Refract Surg       Date:  2011-08-15       Impact factor: 3.351

7.  Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule.

Authors:  Ken Hayashi; Hideyuki Hayashi
Journal:  J Cataract Refract Surg       Date:  2005-02       Impact factor: 3.351

8.  The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge.

Authors:  A L Marcovich; G Kleinmann; D Epstein; A Pollack
Journal:  Br J Ophthalmol       Date:  2006-07-19       Impact factor: 4.638

9.  Risk factors for retinal detachment after cataract surgery: a case-control study.

Authors:  Stephen J Tuft; Darwin Minassian; Paul Sullivan
Journal:  Ophthalmology       Date:  2006-04       Impact factor: 12.079

10.  Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens.

Authors:  Ulrich Mester; Frank Holz; Thomas Kohnen; Chris Lohmann; Manfred Tetz
Journal:  J Cataract Refract Surg       Date:  2008-04       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.