Literature DB >> 18361983

Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens.

Ulrich Mester1, Frank Holz, Thomas Kohnen, Chris Lohmann, Manfred Tetz.   

Abstract

PURPOSE: To evaluate the effect of the AF-1 (UY) blue-light-filtering intraocular lens (IOL) with a yellow chromophore (Hoya) on visual function, including contrast vision and color perception. SETTINGS: Five clinical ophthalmology centers in Germany.
METHODS: Two types of IOLs that were identical except for a blue-light filter on 1 were compared in a prospective randomized multicenter study with intraindividual comparisons. Postoperatively, uncorrected and best corrected visual acuities, pupil size, contrast vision (Early Treatment Diabetic Retinopathy Study chart, functional acuity contrast test, photopic, mesopic, mesopic with glare), and color discrimination (Farnsworth-Munsell 100-hue test, photopic and mesopic) were evaluated.
RESULTS: There were no significant differences between the 2 IOLs except in color vision dependent on blue light. Color perception for blue with the blue-light-filtering IOL was significantly reduced under mesopic conditions over the 12-month follow-up and under photopic conditions over 6 months. Despite the difference, all measured total error scores were within normal range and no patient reported impaired color vision.
CONCLUSIONS: The blue-light-filtering IOL with a yellow chromophore had no effect on contrast vision and visual acuity. However, the impairment of color perception for blue was statistically significant. The impairment of the blue perception did not exceed the normal range or induce subjective disturbance of color vision.

Entities:  

Mesh:

Year:  2008        PMID: 18361983     DOI: 10.1016/j.jcrs.2007.11.049

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Effect on contrast sensitivity after clear, yellow and orange intraocular lens implantation.

Authors:  Sabyasachi Bandyopadhyay; Mita Saha; Asim Chakrabarti; Abhik Sinha
Journal:  Int Ophthalmol       Date:  2015-08-19       Impact factor: 2.031

2.  A comparison of visual outcomes in three different types of monofocal intraocular lenses.

Authors:  Vijay Shetty; Suhas S Haldipurkar; Rujuta Gore; Rita Dhamankar; Anirban Paik; Maninder Singh Setia
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

3.  [Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Authors:  A Frings; I Steinbrugger; E Wissiak; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Ophthalmologe       Date:  2012-06       Impact factor: 1.059

4.  Accelerated 20-year sunlight exposure simulation of a photochromic foldable intraocular lens in a rabbit model.

Authors:  Liliana Werner; Salwa Abdel-Aziz; Carolee Cutler Peck; Bryan Monson; Ladan Espandar; Brian Zaugg; Jack Stringham; Chris Wilcox; Nick Mamalis
Journal:  J Cataract Refract Surg       Date:  2011-02       Impact factor: 3.351

5.  Role of short-wavelength filtering lenses in delaying myopia progression and amelioration of asthenopia in juveniles.

Authors:  Hai-Lan Zhao; Jin Jiang; Jie Yu; Hai-Ming Xu
Journal:  Int J Ophthalmol       Date:  2017-08-18       Impact factor: 1.779

Review 6.  Cataract surgery with implantation of an artificial lens.

Authors:  Thomas Kohnen; Martin Baumeister; Daniel Kook; Oliver K Klaproth; Christian Ohrloff
Journal:  Dtsch Arztebl Int       Date:  2009-10-23       Impact factor: 5.594

Review 7.  Recent studies provide an updated clinical perspective on blue light-filtering IOLs.

Authors:  James A Davison; Anil S Patel; Joao P Cunha; Jim Schwiegerling; Orkun Muftuoglu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-05-17       Impact factor: 3.117

Review 8.  Comparison of blue light-filtering IOLs and UV light-filtering IOLs for cataract surgery: a meta-analysis.

Authors:  Xiao-feng Zhu; Hai-dong Zou; Yong-fu Yu; Qian Sun; Nai-qing Zhao
Journal:  PLoS One       Date:  2012-03-07       Impact factor: 3.240

Review 9.  Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

Authors:  Laura E Downie; Ljoudmila Busija; Peter R Keller
Journal:  Cochrane Database Syst Rev       Date:  2018-05-22

10.  Patient-Reported Difference following Implantation of a Blue Light-Filtering Aspheric Intraocular Lens and a UV-Filtering Aspheric Intraocular Lens.

Authors:  Cédric Schweitzer; Joseph Colin
Journal:  Case Rep Ophthalmol       Date:  2013-11-08
View more