Impact of intraocular lens haptic design and orientation on decentration and tilt.

Alja Crnej1, Nino Hirnschall, Yutaro Nishi, Vinod Gangwani, Juan Tabernero, Pablo Artal, Oliver Findl.   

Abstract

PURPOSE: To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter.
SETTING: Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.
DESIGN: Randomized pilot study with intrapatient comparison.
METHODS: In part 1 of this study, patients received plate-haptic IOLs (Akreos Adapt) in both eyes that were positioned vertically in 1 eye and horizontally in the other eye. In part 2, patients received a 1-piece IOL (Acrysof SA60AT) in 1 eye and a 3-piece IOL (Acrysof MA60AC) in the contralateral eye. Decentration and tilt were measured 1 month and 3 months postoperatively with a new Purkinje meter.
RESULTS: In part 1 (n = 15), the mean decentration of plate-haptic IOLs was 0.4 mm ± 0.2 (SD) with vertical orientation and 0.4 ± 0.2 mm with horizontal orientation and the mean tilt, 1.5 ± 1.1 degrees and 2.9 ± 0.9 degrees, respectively. In part 2 (n = 15), the mean decentration was 0.4 ± 0.3 mm with 1-piece IOLs and 0.6 ± 0.8 mm with 3-piece IOLs and the mean tilt, 2.2 ± 7.2 degrees and 5.3 ± 2.4 degrees, respectively.
CONCLUSIONS: Three-piece IOLs had a greater tendency toward more decentration than 1-piece IOLs, perhaps because of slight deformation of 1 or both haptics during implantation or inaccuracies in production when the haptics are manually placed into the optic. The IOL orientation for plate-haptic IOLs appeared to have no effect on IOL position. The Purkinje meter was useful in assessing the capsule bag performance of the IOLs. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21840681     DOI: 10.1016/j.jcrs.2011.04.028

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Early clinical outcome with a new monofocal microincision intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int Ophthalmol       Date:  2016-01-16       Impact factor: 2.031

2.  The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique.

Authors:  Tansu Erakgun; Hamidu Hamisi Gobeka
Journal:  Int Ophthalmol       Date:  2021-05-20       Impact factor: 2.031

3.  [Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Authors:  A Frings; I Steinbrugger; E Wissiak; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Ophthalmologe       Date:  2012-06       Impact factor: 1.059

4.  Lens oscillations in the human eye. Implications for post-saccadic suppression of vision.

Authors:  Juan Tabernero; Pablo Artal
Journal:  PLoS One       Date:  2014-04-22       Impact factor: 3.240

5.  Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Authors:  Mengmeng Wang; Christine Carole C Corpuz; Megumi Fujiwara; Minoru Tomita
Journal:  Clin Ophthalmol       Date:  2014-05-14

6.  Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.

Authors:  Takashi Fujikado; Makoto Saika
Journal:  Clin Ophthalmol       Date:  2014-11-28

Review 7.  A Review of Complicated Cataract in Retinitis Pigmentosa: Pathogenesis and Cataract Surgery.

Authors:  Yingying Hong; Hongzhe Li; Yang Sun; Yinghong Ji
Journal:  J Ophthalmol       Date:  2020-12-21       Impact factor: 1.909

8.  Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

Authors:  Shuhei Kimura; Yuki Morizane; Yusuke Shiode; Masayuki Hirano; Shinichiro Doi; Shinji Toshima; Atsushi Fujiwara; Fumio Shiraga
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

9.  Determinants of intraocular lens tilt and decentration after cataract surgery.

Authors:  Xiaoxun Gu; Xiaoyun Chen; Guangyao Yang; Wei Wang; Wei Xiao; Guangming Jin; Lanhua Wang; Ye Dai; Xiaoting Ruan; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Ann Transl Med       Date:  2020-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.