Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold.

Michael A Bolen1, Randolph M Setser, Ruvin S Gabriel, Rahul D Renapurkar, Yasmeen Tandon, Michael L Lieber, Milind Y Desai, Scott D Flamm.   

Abstract

Flow assessment with phase contrast magnetic resonance imaging (PC-MRI) protocols is an important component of a comprehensive cardiovascular MR (CMR) assessment. Breath-hold (BH) and non-breath-hold (NBH) PC-MRI protocols are widely available for this imaging modality. Because flow in the great vessels is known to vary with the respiratory cycle, we hypothesized that these 2 approaches might yield different results in the clinical assessment of forward and regurgitant flow in the ascending aorta. Further, given renewed awareness of the possible effect of velocity offsets in PC-MRI, we also sought to evaluate the impact of BH and NBH protocols on this potential source of error. A prospective observational study was performed in 55 consecutive patients referred for clinical CMR of the thoracic aorta. Both BH and NBH protocols were performed at the sinotubular junction and at the mid ascending aorta. Ten additional patients underwent repeated scanning at the mid ascending aorta with both BH and NBH protocols so that protocol variability could be assessed. Finally, ten patients were scanned with both BH and NBH protocols, and phantoms were then imaged with identical imaging parameters so that offset errors associated with each protocol could be evaluated. Forward flow was generally greater with the NBH protocol than with the BH protocol (mean values 102.1 mL vs. 97.9 mL; P = 0.0004). The Bland-Altman limits of agreement were quite wide for all indices (e.g, forward flow, -26.7 mL, +18.2 mL), which suggests that results from BH and NBH protocols cannot be interchanged with confidence. Estimated phase offset errors were similar for both protocols and were generally within acceptable ranges at the mid ascending level, with slightly higher values observed at the sinotubular junction for the BH technique. We observed differences in flow values with BH and NBH protocols for PC-MRI. This finding is relevant to patients imaged serially for the evaluation of cardiac output or valve (aortic or mitral) insufficiency, for whom adherence to one PC-MRI breathing protocol is likely most effective.

Entities:  

Mesh:

Year:  2012        PMID: 22527258     DOI: 10.1007/s10554-012-0047-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  19 in total

1.  Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI.

Authors:  H Sakuma; N Kawada; H Kubo; Y Nishide; K Takano; N Kato; K Takeda
Journal:  Magn Reson Med       Date:  2001-02       Impact factor: 4.668

2.  Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging.

Authors:  M W de Haan; M Kouwenhoven; A G Kessels; J M van Engelshoven
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

3.  Clinical blood flow quantification with segmented k-space magnetic resonance phase velocity mapping.

Authors:  George P Chatzimavroudis; Haosen Zhang; Sandra S Halliburton; James R Moore; Orlando P Simonetti; Paulo R Schvartzman; Arthur E Stillman; Richard D White
Journal:  J Magn Reson Imaging       Date:  2003-01       Impact factor: 4.813

4.  MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers.

Authors:  Sebastian Ley; Christian Fink; Michael Puderbach; Julia Zaporozhan; Christian Plathow; Monika Eichinger; Waldemar Hosch; Karl-Friedrich Kreitner; Hans-Ulrich Kauczor
Journal:  AJR Am J Roentgenol       Date:  2006-08       Impact factor: 3.959

Review 5.  Flow measurement by magnetic resonance: a unique asset worth optimising.

Authors:  Philip J Kilner; Peter D Gatehouse; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

6.  The application of phase shifts in NMR for flow measurement.

Authors:  D N Firmin; G L Nayler; P J Kilner; D B Longmore
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Measurement of caval blood flow with MRI during respiratory maneuvers: implications for vascular contrast opacification on pulmonary CT angiographic studies.

Authors:  Ronald S Kuzo; Robert A Pooley; Julia E Crook; Michael G Heckman; Thomas C Gerber
Journal:  AJR Am J Roentgenol       Date:  2007-03       Impact factor: 3.959

9.  Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques.

Authors:  W G Hundley; H F Li; J E Willard; C Landau; R A Lange; B M Meshack; L D Hillis; R M Peshock
Journal:  Circulation       Date:  1995-09-01       Impact factor: 29.690

10.  Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance.

Authors:  Nina Ajmone Marsan; Jos J M Westenberg; Claudia Ypenburg; Victoria Delgado; Rutger J van Bommel; Stijntje D Roes; Gaetano Nucifora; Rob J van der Geest; Albert de Roos; Johan C Reiber; Martin J Schalij; Jeroen J Bax
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more
  4 in total

1.  Cardiac index after acute ST-segment elevation myocardial infarction measured with phase-contrast cardiac magnetic resonance imaging.

Authors:  Gert Klug; Sebastian Johannes Reinstadler; Hans-Josef Feistritzer; Christian Kremser; Johannes P Schwaiger; Martin Reindl; Johannes Mair; Silvana Müller; Agnes Mayr; Wolfgang-Michael Franz; Bernhard Metzler
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

Review 2.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

3.  Results of Late Gadolinium Enhancement in Children Affected by Dilated Cardiomyopathy.

Authors:  Giuseppe Muscogiuri; Paolo Ciliberti; Domenico Mastrodicasa; Marcello Chinali; Gabriele Rinelli; Teresa Pia Santangelo; Carmela Napolitano; Benedetta Leonardi; Aurelio Secinaro
Journal:  Front Pediatr       Date:  2017-02-06       Impact factor: 3.418

4.  Cardiac magnetic resonance systematically overestimates mitral regurgitations by the indirect method.

Authors:  Litten Bertelsen; Niels Vejlstrup; Laura Andreasen; Morten Salling Olesen; Jesper Hastrup Svendsen
Journal:  Open Heart       Date:  2020-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.