Literature DB >> 30188810

Acousto-Optic Catheter Tracking Sensor for Interventional MRI Procedures.

Yusuf Samet Yaras, Sarp Satir, Cagla Ozsoy, Rajiv Ramasawmy, Adrienne E Campbell-Washburn, Robert J Lederman, Ozgur Kocaturk, F Levent Degertekin.   

Abstract

OBJECTIVE: The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers.
METHODS: The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5 T MRI system in comparison with an active tracking marker.
RESULTS: Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment.
CONCLUSION: Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. SIGNIFICANCE: Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.

Entities:  

Mesh:

Year:  2018        PMID: 30188810      PMCID: PMC6401342          DOI: 10.1109/TBME.2018.2868830

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  26 in total

1.  Development of an optical fiber hydrophone with fiber Bragg grating

Authors: 
Journal:  Ultrasonics       Date:  2000-03       Impact factor: 2.890

2.  An optical system for wireless detuning of parallel resonant circuits.

Authors:  E Y Wong; Q Zhang; J L Duerk; J S Lewin; M Wendt
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

3.  Active MR guidance of interventional devices with target-navigation.

Authors:  Q Zhang; M Wendt; A J Aschoff; L Zheng; J S Lewin; J L Duerk
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

4.  In vivo safe catheter visualization and slice tracking using an optically detunable resonant marker.

Authors:  Steffen Weiss; Titus Kuehne; Florian Brinkert; Gabriele Krombach; Marcus Katoh; Tobias Schaeffter; Rolf W Guenther; Arno Buecker
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

Review 5.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

6.  Multiplexed fiber Bragg grating strain-sensor system with a fiber Fabry - Perot wavelength filter.

Authors:  A D Kersey; T A Berkoff; W W Morey
Journal:  Opt Lett       Date:  1993-08-15       Impact factor: 3.776

7.  MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique.

Authors:  C J Bakker; R M Hoogeveen; W F Hurtak; J J van Vaals; M A Viergever; W P Mali
Journal:  Radiology       Date:  1997-01       Impact factor: 11.105

8.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes.

Authors:  M E Ladd; H H Quick
Journal:  Magn Reson Med       Date:  2000-04       Impact factor: 4.668

Review 9.  MRI-guided congenital cardiac catheterization and intervention: the future?

Authors:  Phillip Moore
Journal:  Catheter Cardiovasc Interv       Date:  2005-09       Impact factor: 2.692

10.  Cumulative patient effective dose in cardiology.

Authors:  G Bedetti; N Botto; M G Andreassi; C Traino; E Vano; E Picano
Journal:  Br J Radiol       Date:  2008-05-28       Impact factor: 3.039

View more
  3 in total

1.  Sensitivity and phase response of FBG based acousto-optic sensors for real-time MRI applications.

Authors:  Yusuf Samet Yaras; Dursun Korel Yildirim; Ozgur Kocaturk; F Levent Degertekin
Journal:  OSA Contin       Date:  2020-03-15

2.  Real-time device tracking under MRI using an acousto-optic active marker.

Authors:  Yusuf S Yaras; Dursun Korel Yildirim; Daniel A Herzka; Toby Rogers; Adrienne E Campbell-Washburn; Robert J Lederman; F Levent Degertekin; Ozgur Kocaturk
Journal:  Magn Reson Med       Date:  2020-12-21       Impact factor: 3.737

3.  Fabrication and Qualitative Analysis of an Optical Fibre EFPI-Based Temperature Sensor.

Authors:  Fintan McGuinness; Aidan Cloonan; Mohamed Oubaha; Dinesh Babu Duraibabu; M Mahmood Ali; Gerald Kilkelly; Emma Tobin; Gabriel Leen
Journal:  Sensors (Basel)       Date:  2021-06-29       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.