Literature DB >> 22491010

Evaluation of deformable image registration and a motion model in CT images with limited features.

F Liu1, Y Hu, Q Zhang, R Kincaid, K A Goodman, G S Mageras.   

Abstract

Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known displacement fields, physical deformable abdominal phantom with implanted fiducials in the liver and small liver structures in patient images. The motion model is derived from a principal component analysis that relates volumetric deformations with the motion of the diaphragm or fiducials in the RCCT. Patient data analysis compares DIR with rigid registration as ground truth: the mean ± standard deviation 3D discrepancy of liver structure centroid positions is 2.0 ± 2.2 mm. DIR discrepancy in the software phantom is 3.8 ± 2.0 mm in lung and 3.7 ± 1.8 mm in abdomen; discrepancies near the chest wall are larger than indicated by image feature matching. Marker's 3D discrepancy in the physical phantom is 3.6 ± 2.8 mm. The results indicate that visible features in the images are important for guiding the DIR algorithm. Motion model accuracy is comparable to DIR, indicating that two principal components are sufficient to describe DIR-derived deformation in these datasets.

Entities:  

Mesh:

Year:  2012        PMID: 22491010      PMCID: PMC3349335          DOI: 10.1088/0031-9155/57/9/2539

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Validation of medical image processing in image-guided therapy.

Authors:  Pierre Jannin; J Michael Fitzpatrick; David J Hawkes; Xavier Pennec; Ramin Shahidi; Michael W Vannier
Journal:  IEEE Trans Med Imaging       Date:  2002-12       Impact factor: 10.048

Review 2.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

3.  Re-optimization in adaptive radiotherapy.

Authors:  Chuan Wu; Robert Jeraj; Gustavo H Olivera; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2002-09-07       Impact factor: 3.609

4.  Fast free-form deformable registration via calculus of variations.

Authors:  Weiguo Lu; Ming-Li Chen; Gustavo H Olivera; Kenneth J Ruchala; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

5.  Results of a multi-institution deformable registration accuracy study (MIDRAS).

Authors:  Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-11-10       Impact factor: 7.038

6.  Enhanced 4D cone-beam CT with inter-phase motion model.

Authors:  Tianfang Li; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

7.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration.

Authors:  Michael Velec; Joanne L Moseley; Cynthia L Eccles; Tim Craig; Michael B Sharpe; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-21       Impact factor: 7.038

8.  A model to accumulate fractionated dose in a deforming organ.

Authors:  D Yan; D A Jaffray; J W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-06-01       Impact factor: 7.038

9.  Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines.

Authors:  Martha M Coselmon; James M Balter; Daniel L McShan; Marc L Kessler
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

10.  Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation.

Authors:  M Birkner; D Yan; M Alber; J Liang; F Nüsslin
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

View more
  14 in total

1.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

2.  A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities.

Authors:  Amy Yuan; Jie Wei; Carl P Gaebler; Hailiang Huang; Devin Olek; Guang Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-09-03       Impact factor: 7.038

3.  Adaptive radiotherapy for NSCLC patients: utilizing the principle of energy conservation to evaluate dose mapping operations.

Authors:  Hualiang Zhong; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2017-05-05       Impact factor: 3.609

4.  Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients.

Authors:  Lei Zhang; Fang-Fang Yin; Tian Li; Xinzhi Teng; Haonan Xiao; Wendy Harris; Lei Ren; Feng-Ming Spring Kong; Hong Ge; Ronghu Mao; Jing Cai
Journal:  Med Phys       Date:  2021-11-18       Impact factor: 4.506

5.  An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation.

Authors:  Taoran Cui; G Wilson Miller; John P Mugler; Gordon D Cates; Jaime F Mata; Eduard E de Lange; Qijie Huang; Talissa A Altes; Fang-Fang Yin; Jing Cai
Journal:  Med Phys       Date:  2018-10-23       Impact factor: 4.071

6.  Bidirectional elastic image registration using B-spline affine transformation.

Authors:  Suicheng Gu; Xin Meng; Frank C Sciurba; Hongxia Ma; Joseph Leader; Naftali Kaminski; David Gur; Jiantao Pu
Journal:  Comput Med Imaging Graph       Date:  2014-01-25       Impact factor: 4.790

7.  A robust deformable image registration enhancement method based on radial basis function.

Authors:  Xiao Liang; Fang-Fang Yin; Chunhao Wang; Jing Cai
Journal:  Quant Imaging Med Surg       Date:  2019-07

8.  Using patient-specific phantoms to evaluate deformable image registration algorithms for adaptive radiation therapy.

Authors:  Nick Stanley; Carri Glide-Hurst; Jinkoo Kim; Jeffrey Adams; Shunshan Li; Ning Wen; Indrin J Chetty; Hualiang Zhong
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

9.  Making the right software choice for clinically used equipment in radiation oncology.

Authors:  Hilke Vorwerk; Klemens Zink; Daniela Michaela Wagner; Rita Engenhart-Cabillic
Journal:  Radiat Oncol       Date:  2014-06-23       Impact factor: 3.481

10.  Quantitative analysis of respiration-related movement for abdominal artery in multiphase hepatic CT.

Authors:  Yang-Hsien Lin; Shih-Min Huang; Chin-Yi Huang; Yun-Niang Tu; Shing-Hong Liu; Tzung-Chi Huang
Journal:  PLoS One       Date:  2014-12-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.