Literature DB >> 24530210

Bidirectional elastic image registration using B-spline affine transformation.

Suicheng Gu1, Xin Meng1, Frank C Sciurba2, Hongxia Ma3, Joseph Leader1, Naftali Kaminski2, David Gur1, Jiantao Pu4.   

Abstract

A registration scheme termed as B-spline affine transformation (BSAT) is presented in this study to elastically align two images. We define an affine transformation instead of the traditional translation at each control point. Mathematically, BSAT is a generalized form of the affine transformation and the traditional B-spline transformation (BST). In order to improve the performance of the iterative closest point (ICP) method in registering two homologous shapes but with large deformation, a bidirectional instead of the traditional unidirectional objective/cost function is proposed. In implementation, the objective function is formulated as a sparse linear equation problem, and a sub-division strategy is used to achieve a reasonable efficiency in registration. The performance of the developed scheme was assessed using both two-dimensional (2D) synthesized dataset and three-dimensional (3D) volumetric computed tomography (CT) data. Our experiments showed that the proposed B-spline affine model could obtain reasonable registration accuracy.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Affine registration; B-spline registration; Iterative closest point; Sparse linear equations; Spline affine registration

Mesh:

Year:  2014        PMID: 24530210      PMCID: PMC4019704          DOI: 10.1016/j.compmedimag.2014.01.002

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  39 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Shape "break-and-repair" strategy and its application to automated medical image segmentation.

Authors:  Jiantao Pu; David S Paik; Xin Meng; Justus E Roos; Geoffrey D Rubin
Journal:  IEEE Trans Vis Comput Graph       Date:  2011-01       Impact factor: 4.579

3.  Topology preserving deformable image matching using constrained hierarchical parametric models.

Authors:  O Musse; F Heitz; J P Armspach
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

4.  Automatic lung nodule matching on sequential CT images.

Authors:  Helen Hong; Jeongjin Lee; Yeny Yim
Journal:  Comput Biol Med       Date:  2008-04-15       Impact factor: 4.589

5.  Image matching as a diffusion process: an analogy with Maxwell's demons.

Authors:  J P Thirion
Journal:  Med Image Anal       Date:  1998-09       Impact factor: 8.545

6.  Intensity-Based Image Registration by Nonparametric Local Smoothing.

Authors:  Chen Xing; Peihua Qiu
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2011-02-17       Impact factor: 6.226

7.  Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy.

Authors:  He Wang; Lei Dong; Jennifer O'Daniel; Radhe Mohan; Adam S Garden; K Kian Ang; Deborah A Kuban; Mark Bonnen; Joe Y Chang; Rex Cheung
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

8.  Early registration of diffusion tensor images for group tractography of dystonia patients.

Authors:  An Vo; Miklos Argyelan; David Eidelberg; Aziz M Uluǧ
Journal:  J Magn Reson Imaging       Date:  2012-09-17       Impact factor: 4.813

9.  The Pittsburgh Lung Screening Study (PLuSS): outcomes within 3 years of a first computed tomography scan.

Authors:  David O Wilson; Joel L Weissfeld; Carl R Fuhrman; Stephen N Fisher; Paula Balogh; Rodney J Landreneau; James D Luketich; Jill M Siegfried
Journal:  Am J Respir Crit Care Med       Date:  2008-07-17       Impact factor: 21.405

10.  Robust Point Set Registration Using Gaussian Mixture Models.

Authors:  Bing Jian; Baba C Vemuri
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2010-12-23       Impact factor: 6.226

View more
  3 in total

Review 1.  Data Augmentation for Brain-Tumor Segmentation: A Review.

Authors:  Jakub Nalepa; Michal Marcinkiewicz; Michal Kawulok
Journal:  Front Comput Neurosci       Date:  2019-12-11       Impact factor: 2.380

2.  Fully Automatic Registration Methods for Chest X-Ray Images.

Authors:  Yu-Ching Lee; Muhammad Adil Khalil; Jui-Huan Lee; Abdan Syakura; Yi-Fang Ding; Ching-Wei Wang
Journal:  J Med Biol Eng       Date:  2021-11-03       Impact factor: 1.553

3.  Three-dimensional Reconstruction of Peripheral Nerve Internal Fascicular Groups.

Authors:  Yingchun Zhong; Liping Wang; Jianghui Dong; Yi Zhang; Peng Luo; Jian Qi; Xiaolin Liu; Cory J Xian
Journal:  Sci Rep       Date:  2015-11-24       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.