Literature DB >> 21282753

Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

D J Langton1, T J Joyce, S S Jameson, J Lord, M Van Orsouw, J P Holland, A V F Nargol, K A De Smet.   

Abstract

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with ARMD. The median chromium and cobalt concentrations in the failed group were significantly higher than in the control group (p < 0.001). Survival analysis showed a failure rate in the patients with Articular Surface Replacement of 12.8% [corrected] at five years, compared with < 1% at five years for the Conserve Plus and 1.5% at ten years for the Birmingham Hip Resurfacing. Two ARMD patients had relatively low wear of the retrieved components. Increased wear from the metal-on-metal bearing surface was associated with an increased rate of failure secondary to ARMD. However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21282753     DOI: 10.1302/0301-620X.93B2.25099

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  111 in total

1.  Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data.

Authors:  Reinhard Schuh; Daniel Neumann; Rauend Rauf; Jochen Hofstaetter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2012-02-22       Impact factor: 3.075

2.  Management of failed metal-on-metal total hip arthroplasty.

Authors:  Justin W Griffin; Michele D'Apuzzo; James A Browne
Journal:  World J Orthop       Date:  2012-06-18

Review 3.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  A more reliable method to assess acetabular component position.

Authors:  John V Tiberi; Nicholas Pulos; Michael Kertzner; Thomas P Schmalzried; Thomas P Schmlazried
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

5.  Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings.

Authors:  Andrea Lazik; Stefan Landgraeber; Patrick Schulte; Oliver Kraff; Thomas C Lauenstein; Jens M Theysohn
Journal:  Skeletal Radiol       Date:  2015-03-25       Impact factor: 2.199

6.  CORR Insights®: What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study.

Authors:  Thomas K Fehring
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

7.  Reply to the Letter to the Editor: Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  Sang-Hyun Park; Zhen Lu; Robert S Hastings; Patricia A Campbell; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2018-11       Impact factor: 4.176

8.  Letter to the Editor: Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  David J Langton
Journal:  Clin Orthop Relat Res       Date:  2018-11       Impact factor: 4.176

9.  Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients.

Authors:  Jonathan Hutt; Ziad Harb; Ian Gill; Fadhil Kashif; John Miller; Matthew Dodd
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

10.  The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial.

Authors:  Maik Stiehler; Jens Goronzy; Albrecht Hartmann; Frank Krummenauer; Klaus-Peter Günther
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.