Literature DB >> 22476693

Accuracy of cone-beam computed tomography to assess the configuration and extent of ligature-induced peri-implantitis defects. A pilot study.

Vladimir Golubovic1, Ilja Mihatovic, Jürgen Becker, Frank Schwarz.   

Abstract

PURPOSE: This is a pilot study which aims to evaluate the accuracy of cone-beam computed tomography (CBCT) to assess the configuration and extent of ligature-induced peri-implantitis defects.
MATERIALS AND METHODS: Radiographic evaluation of advanced ligature-induced peri-implantitis defects (n = 9) in canine was performed using CBCT (central cross-sections) and compared with the corresponding histomorphometrical measurements of the respective site serving as a validation method. Deviations were calculated for the supracrestal (SC), and intrabony (IC) defect components, as well as defect width (DW) assessed at both vestibular (v) and oral (o) aspects.
RESULTS: Mean differences between CBCT and histological analyses were -0.53 ± 1.48 mm (SC), +0.49 ± 1.18 mm (IC), and +0.18 ± 0.54 mm (DW) at vestibular aspects, and -0.13 ± 0.44 mm (SC), -0.05 ± 0.62 mm (IC), and +0.15 ± 0.48 mm (DW) at the oral aspects (P > 0.05; paired t test, respectively).
CONCLUSION: CBCT may represent an accurate diagnostic tool to estimate the histological extent of advanced peri-implantitis defects.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22476693     DOI: 10.1007/s10006-012-0320-2

Source DB:  PubMed          Journal:  Oral Maxillofac Surg        ISSN: 1865-1550


  14 in total

1.  Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography.

Authors:  Touraj Razavi; Richard M Palmer; Jonathan Davies; Ron Wilson; Paul J Palmer
Journal:  Clin Oral Implants Res       Date:  2010-07       Impact factor: 5.977

2.  Digital volume tomography in the diagnosis of peri-implant defects: an in vitro study on native pig mandibles.

Authors:  Reiner Mengel; Björn Kruse; Lavin Flores-de-Jacoby
Journal:  J Periodontol       Date:  2006-07       Impact factor: 6.993

Review 3.  Peri-implant diseases: diagnosis and risk indicators.

Authors:  Lisa J A Heitz-Mayfield
Journal:  J Clin Periodontol       Date:  2008-09       Impact factor: 8.728

4.  What is cone-beam CT and how does it work?

Authors:  William C Scarfe; Allan G Farman
Journal:  Dent Clin North Am       Date:  2008-10

5.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

6.  Surgical therapy of advanced ligature-induced peri-implantitis defects: cone-beam computed tomographic and histological analysis.

Authors:  Frank Schwarz; Narja Sahm; Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker
Journal:  J Clin Periodontol       Date:  2011-08-31       Impact factor: 8.728

7.  Long-term stability of surgical bone regenerative procedures of peri-implantitis lesions in a prospective case-control study over 3 years.

Authors:  Ann-Marie Roos-Jansåker; Christel Lindahl; G Rutger Persson; Stefan Renvert
Journal:  J Clin Periodontol       Date:  2011-04-13       Impact factor: 8.728

8.  Impact of defect configuration on the clinical outcome following surgical regenerative therapy of peri-implantitis.

Authors:  Frank Schwarz; Narja Sahm; Katrin Schwarz; Jürgen Becker
Journal:  J Clin Periodontol       Date:  2010-03-24       Impact factor: 8.728

9.  Periimplant diseases: where are we now?--Consensus of the Seventh European Workshop on Periodontology.

Authors:  Niklaus P Lang; Tord Berglundh
Journal:  J Clin Periodontol       Date:  2011-03       Impact factor: 8.728

10.  Experimental breakdown of peri-implant and periodontal tissues. A study in the beagle dog.

Authors:  J Lindhe; T Berglundh; I Ericsson; B Liljenberg; C Marinello
Journal:  Clin Oral Implants Res       Date:  1992-03       Impact factor: 5.977

View more
  6 in total

1.  Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters.

Authors:  Lauren O L Bohner; Pedro Tortamano; Juliana Marotti
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

Review 2.  Peri-implantitis. Part 1: Scope of the problem.

Authors:  A Alani; M Kelleher; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

3.  Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects.

Authors:  Jun Ho Kim; Reinaldo Abdala-Júnior; Luciana Munhoz; Arthur Rodriguez Gonzalez Cortes; Plauto Christopher Aranha Watanabe; Claudio Costa; Emiko Saito Arita
Journal:  Imaging Sci Dent       Date:  2020-06-18

4.  Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study.

Authors:  Paweł Sawicki; Piotr Regulski; Artur Winiarski; Paweł J Zawadzki
Journal:  J Clin Med       Date:  2022-07-02       Impact factor: 4.964

5.  Volumetric Analysis of Gingival Crevicular Fluid and Peri-Implant Sulcus Fluid in Healthy and Diseased Sites: A Cross-Sectional Split-Mouth Pilot Study.

Authors:  Lorenzo Bevilacqua; Matteo De Biasi; Maria Giulia Lorenzon; Costanza Frattini; Daniele Angerame
Journal:  Open Dent J       Date:  2016-04-30

6.  Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study.

Authors:  Chu-Nan Zhang; Yu Zhu; Lin-Feng Fan; Xiao Zhang; Yin-Hua Jiang; Ying-Xin Gu
Journal:  J Dent Sci       Date:  2020-11-14       Impact factor: 2.080

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.