Literature DB >> 16805688

Digital volume tomography in the diagnosis of peri-implant defects: an in vitro study on native pig mandibles.

Reiner Mengel1, Björn Kruse, Lavin Flores-de-Jacoby.   

Abstract

BACKGROUND: The aim of this study of native pig mandibles was to investigate the accuracy and quality of the representation of peri-implant defects by intraoral radiography (IR), panoramic radiography (PR), computer tomography (CT), and digital volume tomography (DVT).
METHODS: The examination was carried out on 19 native pig mandibles. In the toothless sections of the mandibles, one or two implants were inserted. Following the standardized preparation of peri-implant defects (11 each of dehiscences, fenestrations, and 2- to 3-walled intrabony defects), IR, PR, CT, and DVT were performed. The peri-implant defects were measured using appropriate software on the digitized IR and PR image programs. As a control method, the peri-implant bone defects were measured directly using a reflecting stereomicroscope with measuring ocular. The statistical comparison between the measurements of the radiographic scans and those of the direct readings of the peri-implant defects was performed with Pearson's correlation coefficient. The quality of the radiographic scans was determined through the subjective perception and detectability of the peri-implant defects by five independent observers.
RESULTS: In the DVT and CT scans, it was possible to measure all the bone defects in three planes. Comparison with the direct peri-implant defect measurements yielded a mean deviation of 0.17+/-0.11 mm for the DVT scans and 0.18+/-0.12 mm for the CT scans. On the IR and PR images, the defects could be detected only in the mesio-distal and cranio-caudal planes. In comparison with the direct measurements of the peri-implant defects, the IR images revealed a mean deviation of 0.34+/-0.30 mm, and the PR images revealed a mean deviation of 0.41+/-0.35 mm. The quality rating of the radiographic images was highest for the DVT scans.
CONCLUSIONS: Overall, the CT and DVT scans displayed only a slight deviation in the extent of the peri-implant defects. Both radiographic imaging techniques permitted imaging of peri-implant defects in three planes, true to scale, and without overlay or distortion. The DVT scans showed the best imaging quality.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16805688     DOI: 10.1902/jop.2006.050424

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  15 in total

1.  Accuracy of cone-beam computed tomography to assess the configuration and extent of ligature-induced peri-implantitis defects. A pilot study.

Authors:  Vladimir Golubovic; Ilja Mihatovic; Jürgen Becker; Frank Schwarz
Journal:  Oral Maxillofac Surg       Date:  2012-04-04

2.  Comparative evaluation of mandibular canal visibility on cross-sectional cone-beam CT images: a retrospective study.

Authors:  Mahogany S Miles; Edwin T Parks; George J Eckert; Steven B Blanchard
Journal:  Dentomaxillofac Radiol       Date:  2015-11-06       Impact factor: 2.419

3.  Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode.

Authors:  K Kamburoglu; E Kolsuz; S Murat; H Eren; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

4.  Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view.

Authors:  K Kamburoğlu; S Murat; C Kılıç; S Yüksel; H Avsever; A Farman; W C Scarfe
Journal:  Dentomaxillofac Radiol       Date:  2014-03-20       Impact factor: 2.419

5.  Accuracy of peri-implant bone evaluation using cone beam CT, digital intra-oral radiographs and histology.

Authors:  L Ritter; M C Elger; D Rothamel; T Fienitz; M Zinser; F Schwarz; J E Zöller
Journal:  Dentomaxillofac Radiol       Date:  2014-05-02       Impact factor: 2.419

6.  Evaluation of dehiscences using cone beam computed tomography.

Authors:  Nicholas Ising; Ki Beom Kim; Eustaquio Araujo; Peter Buschang
Journal:  Angle Orthod       Date:  2011-07-27       Impact factor: 2.079

7.  Diagnostic accuracy of Cone Beam Computed Tomography, conventional and digital radiographs in detecting interproximal caries.

Authors:  Y Safi; N Shamloo Mahmoudi; M M Aghdasi; M Eslami Manouchehri; R Rahimian; S Valizadeh; Z Vasegh; Z Azizi
Journal:  J Med Life       Date:  2015

8.  Evaluation of the distortion rate of panoramic and periapical radiographs in erupted third molar inclination.

Authors:  F Ezoddini Ardakani; M Zangouie Booshehri; B Behniafar
Journal:  Iran J Radiol       Date:  2011-03-30       Impact factor: 0.212

9.  Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Renata Hernandes Tonin
Journal:  Contemp Clin Dent       Date:  2014-07

Review 10.  Accuracy and precision of cone beam computed tomography in periodontal defects measurement (systematic review).

Authors:  Enas Anter; Mohammed Khalifa Zayet; Sahar Hosny El-Dessouky
Journal:  J Indian Soc Periodontol       Date:  2016 May-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.