Literature DB >> 22463868

Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation.

P Adam1, R Philippe, M Ehlinger, O Roche, F Bonnomet, D Molé, M-H Fessy.   

Abstract

INTRODUCTION: Displaced fractures of the femoral neck in the elderly are best treated with arthroplasty. The type of arthroplasty to be used, either hemi- or total hip arthroplasty, remains controversial as total hip replacements potentially have a higher rate of dislocation. HYPOTHESIS: Dual mobility cups have a low dislocation rate when used to manage acute fractures of the femoral neck. PATIENTS AND METHODS: In a multicenter prospective study conducted in France over an inclusion time of 3 months, all displaced fractures of the femoral neck treated with arthroplasty were operated on with insertion of a dual mobility cup. Patients had clinical and radiological assessment at 3, 6, and 9 months postoperative.
RESULTS: Two hundred and fourteen hips in 214 patients with a mean age of 83 years (range, 70-103 years) were included. None of the patients was lost to follow-up. The mortality rate after 9 months was 19%. Two patients (1%) had early postoperative infection successfully treated with lavage and antibiotics. Three patients (1.4%), operated through a posterior approach, presented one postoperative dislocation, all of which were posterior. Reduction was performed through closed external manipulation under general anesthesia. There was no recurrence of dislocation. DISCUSSION: This low rate of dislocation after acute total hip replacement using dual mobility design cups favorably compares with hemiarthroplasties. Dual mobility cups might therefore be considered a valuable option to prevent postoperative dislocation when treating displaced intracapsular fractures of the proximal femur in elderly patients if a total hip replacement is recommended. Further study is needed before extending the indications for total hip arthroplasty following a fracture of the femoral neck, to assess the potential cost and complications of a longer procedure with its potential acetabular complication, and weigh them against the potential benefits.
Copyright © 2012 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22463868     DOI: 10.1016/j.otsr.2012.01.005

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  32 in total

1.  Dual mobility cup: dislocation rate and survivorship at ten years of follow-up.

Authors:  Jean-Louis Prudhon; André Ferreira; Régis Verdier
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

2.  Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Authors:  Sebastian S Mukka; Sarwar S Mahmood; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Orthop Rev (Pavia)       Date:  2013-06-11

Review 3.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 4.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

Review 5.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

6.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

7.  Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures.

Authors:  Anne S Bensen; Thomas Jakobsen; Niels Krarup
Journal:  Int Orthop       Date:  2014-01-18       Impact factor: 3.075

Review 8.  Wear of dual-mobility cups: a review article.

Authors:  Anna Di Laura; Harry Hothi; Clement Battisti; Arianna Cerquiglini; Johann Henckel; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-12-09       Impact factor: 3.075

9.  Total hip arthroplasty using direct anterior approach and dual mobility cup: safe and efficient strategy against post-operative dislocation.

Authors:  Cécile Batailler; Camdon Fary; Pierre Batailler; Elvire Servien; Philippe Neyret; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-16       Impact factor: 3.075

10.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075