BACKGROUND: Inside-out abrasion with externalization of sensing ring or high-voltage cables in St Jude Medical Riata implantable cardioverter-defibrillator leads has been reported. The prevalence of extruded cables, rate of electrical abnormalities, and predictors of failure in Riata leads are unknown. OBJECTIVES: To estimate the incidence of lead failure in the St Jude Medical Riata implantable cardioverter-defibrillator leads and to propose a standard for the fluoroscopic assessment of insulation breakdown. METHODS: Patients undergoing cine-fluoroscopy on Riata implantable cardioverter-defibrillator leads at our institution before January 25, 2012, were included (n = 87). Leads were graded as types 0-3 (0 = normal, 1 = abnormal conductor spacing, 2 ≤1 cm cable extrusion, 3 = >1 cm length extrusion). Comparison to extracted leads (n = 15) was documented. Device interrogation data were used for electrical analysis. RESULTS: The mean time from implant was 5.9 ± 3.45 years. Structural lead failure with externalized cables was seen in 33.3% (29 of 87) of the patients. Thirty-one percent (9 of 29) of the leads with exposed cables showed electrical failure, and 29.7% (19 of 64) of the leads with normal electrical data contained externalized cables. Time from implant ≥5 years predicted structural lead failure (P < 0.05). X-ray grade compared with extracted leads demonstrated a sensitivity and specificity of 86% and 100%, respectively. CONCLUSIONS: Cine-fluoroscopy using a simple scale correlated with the structural integrity of extracted Riata leads. A high percentage of leads with extrusion showed electrical failure. Leads ≥5 years from implant showed a high rate of externalized cables. A large independent multicenter study to determine the prevalence and clinical sequelae of Riata lead failures is warranted.
BACKGROUND: Inside-out abrasion with externalization of sensing ring or high-voltage cables in St Jude Medical Riata implantable cardioverter-defibrillator leads has been reported. The prevalence of extruded cables, rate of electrical abnormalities, and predictors of failure in Riata leads are unknown. OBJECTIVES: To estimate the incidence of lead failure in the St Jude Medical Riata implantable cardioverter-defibrillator leads and to propose a standard for the fluoroscopic assessment of insulation breakdown. METHODS:Patients undergoing cine-fluoroscopy on Riata implantable cardioverter-defibrillator leads at our institution before January 25, 2012, were included (n = 87). Leads were graded as types 0-3 (0 = normal, 1 = abnormal conductor spacing, 2 ≤1 cm cable extrusion, 3 = >1 cm length extrusion). Comparison to extracted leads (n = 15) was documented. Device interrogation data were used for electrical analysis. RESULTS: The mean time from implant was 5.9 ± 3.45 years. Structural lead failure with externalized cables was seen in 33.3% (29 of 87) of the patients. Thirty-one percent (9 of 29) of the leads with exposed cables showed electrical failure, and 29.7% (19 of 64) of the leads with normal electrical data contained externalized cables. Time from implant ≥5 years predicted structural lead failure (P < 0.05). X-ray grade compared with extracted leads demonstrated a sensitivity and specificity of 86% and 100%, respectively. CONCLUSIONS:Cine-fluoroscopy using a simple scale correlated with the structural integrity of extracted Riata leads. A high percentage of leads with extrusion showed electrical failure. Leads ≥5 years from implant showed a high rate of externalized cables. A large independent multicenter study to determine the prevalence and clinical sequelae of Riata lead failures is warranted.
Authors: Peem Lorvidhaya; Ivan Mendoza; Sharmila Sehli; Michael K Atalay; Michael H Kim Journal: J Interv Card Electrophysiol Date: 2013-09-08 Impact factor: 1.900
Authors: Liza P Moorman; J Randall Moorman; John P DiMarco; Rohit Malhotra; Andrew Darby; Kenneth Bilchick; John D Ferguson; J Michael Mangrum; Sandeep Kamath; Pamela K Mason Journal: J Interv Card Electrophysiol Date: 2012-12-20 Impact factor: 1.900
Authors: C W Israel; D Bänsch; D Böcker; C Butter; J Chun; I Deisenhofer; L Eckardt; J-C Geller; T Hanke; T Klingenheben; C Piorkowski; B Schumacher Journal: Herzschrittmacherther Elektrophysiol Date: 2012-06
Authors: Ioana Danciu; James D Cowan; Melissa Basford; Xiaoming Wang; Alexander Saip; Susan Osgood; Jana Shirey-Rice; Jacqueline Kirby; Paul A Harris Journal: J Biomed Inform Date: 2014-02-14 Impact factor: 6.317