Literature DB >> 22447037

Factors associated with exposure of transvaginally placed polypropylene mesh for pelvic organ prolapse.

Karen P Gold1, Renee M Ward, Carl W Zimmerman, Daniel H Biller, Shawn McGuinn, James C Slaughter, Roger R Dmochowski.   

Abstract

INTRODUCTION AND HYPOTHESIS: This study evaluates potential risk factors for mesh exposure following transvaginal placement of polypropylene mesh for pelvic organ prolapse requiring reoperation.
METHODS: We performed a case-control study. Cases had mesh exposure requiring surgical revision; controls had no mesh exposures and were chosen for similar surgical date and type of mesh.
RESULTS: We identified 48 cases and 48 controls. The adjusted odds ratio of having a bleeding complication at the time of mesh implantation was 7.25 [95% confidence interval (CI) 1.47-35.66], smokers versus nonsmokers was 3.17 (95% CI 0.59-17.12), and being 1 year older was 0.96 (95% CI 0.92-1.0), among women with mesh exposure.
CONCLUSIONS: We identified bleeding complications at the time of mesh implantation as a risk factor for mesh exposure requiring reoperation. Despite being one of the largest studies on this topic, our data were inconclusive regarding the impact of other possible factors on mesh exposure.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22447037     DOI: 10.1007/s00192-012-1706-2

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  17 in total

1.  Procedures for pelvic organ prolapse in the United States, 1979-1997.

Authors:  Sarah Hamilton Boyles; Anne M Weber; Leslie Meyn
Journal:  Am J Obstet Gynecol       Date:  2003-01       Impact factor: 8.661

2.  Vaginal mesh erosion after transvaginal repair of cystocele using Gynemesh or Gynemesh-Soft in 138 women: a comparative study.

Authors:  X Deffieux; R de Tayrac; C Huel; J Bottero; A Gervaise; K Bonnet; R Frydman; H Fernandez
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-01-04

Review 3.  Scientific basis for use of grafts during vaginal reconstructive procedures.

Authors:  William Andre Silva; Mickey M Karram
Journal:  Curr Opin Obstet Gynecol       Date:  2005-10       Impact factor: 1.927

4.  ACOG Practice Bulletin No. 85: Pelvic organ prolapse.

Authors: 
Journal:  Obstet Gynecol       Date:  2007-09       Impact factor: 7.661

5.  Words of wisdom. Re: FDA public health notification: serious complications associated with transvaginal placement of surgical mesh in repair of pelvic organ prolapse and stress urinary incontinence.

Authors:  Firouz Daneshgari
Journal:  Eur Urol       Date:  2009-05       Impact factor: 20.096

6.  Vaginal mesh for prolapse: a randomized controlled trial.

Authors:  Cheryl B Iglesia; Andrew I Sokol; Eric R Sokol; Bela I Kudish; Robert E Gutman; Joanna L Peterson; Susan Shott
Journal:  Obstet Gynecol       Date:  2010-08       Impact factor: 7.661

7.  Risk evaluation of smoking and age on the occurrence of postoperative erosions after transvaginal mesh repair for pelvic organ prolapses.

Authors:  Francesco Araco; Gianpiero Gravante; Roberto Sorge; Davide De Vita; Emilio Piccione
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-10-10

8.  Low-weight polypropylene mesh for anterior vaginal wall prolapse: a randomized controlled trial.

Authors:  Reijo Hiltunen; Kari Nieminen; Teuvo Takala; Eila Heiskanen; Mauri Merikari; Kirsti Niemi; Pentti K Heinonen
Journal:  Obstet Gynecol       Date:  2007-08       Impact factor: 7.661

Review 9.  Graft use in transvaginal pelvic organ prolapse repair: a systematic review.

Authors:  Vivian W Sung; Rebecca G Rogers; Joseph I Schaffer; Ethan M Balk; Katrin Uhlig; Joseph Lau; Husam Abed; Thomas L Wheeler; Michelle Y Morrill; Jeffrey L Clemons; David D Rahn; James C Lukban; Lior Lowenstein; Kimberly Kenton; Stephen B Young
Journal:  Obstet Gynecol       Date:  2008-11       Impact factor: 7.661

Review 10.  Open surgical procedures for incisional hernias.

Authors:  Dennis den Hartog; Alphons H M Dur; Wim E Tuinebreijer; Robert W Kreis
Journal:  Cochrane Database Syst Rev       Date:  2008-07-16
View more
  4 in total

1.  Quality of Life, Sexuality, Anatomical Results and Side-effects of Implantation of an Alloplastic Mesh for Cystocele Correction at Follow-up after 36 Months.

Authors:  Christian Fünfgeld; Margit Stehle; Brigit Henne; Jan Kaufhold; Dirk Watermann; Markus Grebe; Mathias Mengel
Journal:  Geburtshilfe Frauenheilkd       Date:  2017-09-25       Impact factor: 2.915

2.  Seeking new surgical predictors of mesh exposure after transvaginal mesh repair.

Authors:  Pei-Ying Wu; Chih-Hung Chang; Meng-Ru Shen; Cheng-Yang Chou; Yi-Ching Yang; Yu-Fang Huang
Journal:  Int Urogynecol J       Date:  2016-03-18       Impact factor: 2.894

3.  Lower exposure rates of partially absorbable mesh compared to nonabsorbable mesh for cystocele treatment: 3-year follow-up of a prospective randomized trial.

Authors:  J Farthmann; D Watermann; A Niesel; C Fünfgeld; A Kraus; F Lenz; H J Augenstein; E Graf; B Gabriel
Journal:  Int Urogynecol J       Date:  2012-08-29       Impact factor: 2.894

4.  Clinical analysis of pain after transvaginal mesh surgery in patients with pelvic organ prolapse.

Authors:  Chang Shi; Ying Zhao; Qing Hu; Runqi Gong; Yitong Yin; Zhijun Xia
Journal:  BMC Womens Health       Date:  2021-01-30       Impact factor: 2.809

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.