Literature DB >> 22439096

Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Seok-Gyu Kim1, Pil-Young Yun, Hyun-Sik Park, June-Sung Shim, Jung-Won Hwang, Young-Kyun Kim.   

Abstract

PURPOSE: The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12-month postloading period.
MATERIALS AND METHODS: Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during one-year postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test.
RESULTS: Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P<.05). Periimplant marginal bone loss (T: 0.27±0.54 mm, C: 0.40±0.55 mm) and periodontal parameters showed no significant difference between the groups (P>.05).
CONCLUSION: Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.

Entities:  

Keywords:  Anodic oxidized; Loading time; Survival

Year:  2012        PMID: 22439096      PMCID: PMC3303916          DOI: 10.4047/jap.2012.4.1.18

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  43 in total

1.  Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study.

Authors:  K Randow; I Ericsson; K Nilner; A Petersson; P O Glantz
Journal:  Clin Oral Implants Res       Date:  1999-02       Impact factor: 5.977

2.  Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandible. A 1-year randomized controlled clinical trial.

Authors:  Giovanni E Salvi; Guido Gallini; Niklaus P Lang
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

3.  Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data.

Authors:  Carlo Mangano; Francesco Mangano; Jamil A Shibli; Lucia Tettamanti; Michele Figliuzzi; Susana d'Avila; Rachel L Sammons; Adriano Piattelli
Journal:  J Periodontol       Date:  2010-07-27       Impact factor: 6.993

4.  The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants.

Authors:  Xavier Rodríguez-Ciurana; Xavier Vela-Nebot; Maribel Segalà-Torres; José Luis Calvo-Guirado; Jordi Cambra; Victor Méndez-Blanco; Dennis P Tarnow
Journal:  Int J Periodontics Restorative Dent       Date:  2009-04       Impact factor: 1.840

5.  Tissue characteristics at microthreaded implants: an experimental study in dogs.

Authors:  Ingemar Abrahamsson; Tord Berglundh
Journal:  Clin Implant Dent Relat Res       Date:  2006       Impact factor: 3.932

6.  The Gingival Index, the Plaque Index and the Retention Index Systems.

Authors:  H Löe
Journal:  J Periodontol       Date:  1967 Nov-Dec       Impact factor: 6.993

Review 7.  Direct bone anchorage of dental implants.

Authors:  T Albrektsson
Journal:  J Prosthet Dent       Date:  1983-08       Impact factor: 3.426

8.  Implant-retained mandibular overdentures with Brånemark System MKII implants: a prospective comparative study between delayed and immediate loading.

Authors:  M Chiapasco; S Abati; E Romeo; G Vogel
Journal:  Int J Oral Maxillofac Implants       Date:  2001 Jul-Aug       Impact factor: 2.804

9.  Osseointegration of Brånemark fixtures using a single-step operating technique. A preliminary prospective one-year study in the edentulous mandible.

Authors:  J P Bernard; U C Belser; J P Martinet; S A Borgis
Journal:  Clin Oral Implants Res       Date:  1995-06       Impact factor: 5.977

10.  Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures.

Authors:  Alan G T Payne; Andrew Tawse-Smith; Warwick D Duncan; Rohana Kumara
Journal:  Clin Oral Implants Res       Date:  2002-12       Impact factor: 5.977

View more
  1 in total

Review 1.  Sandblasted and Acid Etched Titanium Dental Implant Surfaces Systematic Review and Confocal Microscopy Evaluation.

Authors:  Gabriele Cervino; Luca Fiorillo; Gaetano Iannello; Dario Santonocito; Giacomo Risitano; Marco Cicciù
Journal:  Materials (Basel)       Date:  2019-05-30       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.