Literature DB >> 19408476

The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants.

Xavier Rodríguez-Ciurana1, Xavier Vela-Nebot, Maribel Segalà-Torres, José Luis Calvo-Guirado, Jordi Cambra, Victor Méndez-Blanco, Dennis P Tarnow.   

Abstract

A distance of more than 3 mm between two adjacent standard implants has been shown to preserve the interproximal bone peak, resulting in only 0.45 mm of resorption. The purpose of this study was to determine whether use of the platform-switching technique would change the bone resorption patterns between adjacent implants placed less than 3 mm apart. Radiographic studies of bone resorption around 41 pairs of implants placed less than 3 mm apart in 37 patients were carried out. Mean vertical bone resorption was 0.62 mm, and the mean horizontal component was 0.60 mm. The bone peak that extended coronally beyond an imaginary line connecting the two implant-abutment interfaces was measured, and the mean bone height preservation above this interimplant line was 0.24 mm.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19408476

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  16 in total

1.  Three-dimensional finite element analysis of platform switched implant.

Authors:  Se-Young Moon; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

Review 2.  Peri-implantitis. Part 1: Scope of the problem.

Authors:  A Alani; M Kelleher; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

3.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

Review 4.  Influence of subcrestal implant placement compared with equicrestal position on the peri-implant hard and soft tissues around platform-switched implants: a systematic review and meta-analysis.

Authors:  Cristina Valles; Xavier Rodríguez-Ciurana; Marco Clementini; Mariana Baglivo; Blanca Paniagua; Jose Nart
Journal:  Clin Oral Investig       Date:  2018-01-08       Impact factor: 3.573

5.  Congenitally missing maxillary lateral incisors: update on the functional and esthetic parameters of patients treated with implants or space closure and teeth recontouring.

Authors:  Núbia Inocencya Pavesi Pini; Luciana Manzotti De Marchi; Renata Corrêa Pascotto
Journal:  Open Dent J       Date:  2015-01-06

Review 6.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

7.  Case presentation of two patients using diagonal platform-switched double implants for maxillary single-first-molar replacement as the alternative of a single-tooth implant.

Authors:  Yasunori Hotta; Koji Ito; Shinichi Komatsu; Takashi Saito
Journal:  Int J Implant Dent       Date:  2015-11-12

8.  Evaluation of a New Dental Implant Cervical Design in Comparison with a Conventional Design in an Experimental American Foxhound Model.

Authors:  Maria Ángeles Pérez-Albacete Martínez; Carlos Pérez-Albacete Martínez; José Eduardo Maté Sánchez De Val; María Luisa Ramos Oltra; Manuel Fernández Domínguez; Jose Luis Calvo Guirado
Journal:  Materials (Basel)       Date:  2018-03-21       Impact factor: 3.623

9.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

Review 10.  Marginal bone loss in relation to platform switching implant insertion depth: An update.

Authors:  Rocío Alonso-González; Amparo Aloy-Prósper; David Peñarrocha-Oltra; M A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2012-07-01