Literature DB >> 11516001

Implant-retained mandibular overdentures with Brånemark System MKII implants: a prospective comparative study between delayed and immediate loading.

M Chiapasco1, S Abati, E Romeo, G Vogel.   

Abstract

This study was designed to compare the results of immediate and delayed loading of implants with implant-retained mandibular overdentures. Ten patients (test group) received 40 Brånemark System MKII implants (4 per patient) placed in the interforaminal area of the mandible. Standard abutments were immediately screwed to the implants, rigidly connected with a bar, and immediately loaded with an overdenture. Ten patients (control group) received the same type and number of implants in the same area, but the implants were left to heal submerged. Four to 8 months later, standard abutments were screwed to the implants and the same prosthetic procedure was applied. Each implant was evaluated at the time of prosthetic loading and at 6, 12, and 24 months after the initial prosthetic load with the following parameters: modified Plaque Index (MPI), modified Bleeding Index (MBI), probing depth (PD), and Periotest. Peri-implant bone resorption was evaluated on panoramic radiographs taken 12 and 24 months after initial prosthetic loading. No significant differences were found between the 2 groups regarding MPI, MBI, Periotest, peri-implant bone resorption, and PD at 6 and 24 months (P > .05). The only difference was found regarding PD values on the mesial and lingual sites at 12 months (P < .05). The cumulative success rate of implants was 97.5% in both groups. Results from this study showed that immediate loading of endosseous implants rigidly connected with a U-shaped bar does not seem to have any detrimental effect on osseointegration. Conversely, this method significantly shortens the duration of treatment with relevant satisfaction for the patients.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11516001

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  12 in total

1.  Clinical evaluation of early loaded and unloaded implants in edentulous mandible.

Authors:  S Anil Kumar; Nandkishore Sahoo; V Radhakrishnan; H S Sandhu
Journal:  J Maxillofac Oral Surg       Date:  2011-12-28

Review 2.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

Review 3.  Implant rehabilitation in patients with oral lichen planus: an overview.

Authors:  Massimo Petruzzi; Michele De Benedittis; Roberto Cortelazzi; Lucio Milillo; Alberta Lucchese; Rosario Serpico; Felice Roberto Grassi
Journal:  Clin Oral Investig       Date:  2012-03-01       Impact factor: 3.573

4.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

5.  Immediate loading on mandibular edentulous patient with SFI Bar® overdenture.

Authors:  Ha-Young Kim; Ryan Jin-Young Kim; Sarah Qadeer; Chang-Mo Jeong; Sang-Wan Shin; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

6.  Comparative evaluation of bone in mandibular implant retained overdentures using delayed and immediate loading protocol: an in-vivo study.

Authors:  Manesh Lahori; A S Kaul; Sidhartha Chandra; Rahul Nagrath; Himanshu Gupta
Journal:  J Indian Prosthodont Soc       Date:  2012-12-27

7.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14

8.  The efficacy of flapless implant surgery on soft-tissue profile comparing immediate loading implants to delayed loading implants: A comparative clinical study.

Authors:  Deepak Moses Ravindran; Uma Sudhakar; T Ramakrishnan; N Ambalavanan
Journal:  J Indian Soc Periodontol       Date:  2010-10

9.  Evaluation of stability changes in tapered and parallel wall implants: a human clinical trial.

Authors:  Ar Rokn; Aar Rasouli Ghahroudi; A Mesgarzadeh; Aa Miremadi; S Yaghoobi
Journal:  J Dent (Tehran)       Date:  2011-12-20

10.  Prospective study of treatment outcome of implant retained mandibular overdenture: Two years follow-up.

Authors:  Vimal Arora; Dinesh Kumar; V S Legha; K V Arun Kumar
Journal:  Contemp Clin Dent       Date:  2014-04
View more