Literature DB >> 16919018

Tissue characteristics at microthreaded implants: an experimental study in dogs.

Ingemar Abrahamsson1, Tord Berglundh.   

Abstract

PURPOSE: The aim of the present study was to analyze bone tissue reactions at implants with and without a microthread configuration.
MATERIALS AND METHODS: In six beagle dogs, one test and two control implants were installed in one side of the mandible. While both implant types had a similar dimension and surface roughness, the test implants were designed with a microthread configuration in the marginal portion. Abutment connection was performed after 3 months. Another 3 months later, fixed partial dentures (FPDs) were cemented to the maxillary canine and premolars and FPDs were connected to the implants in the mandible. Ten months later, the animals were sacrificed and biopsies from each implant region were processed for histological analysis. Radiographs were obtained at implant placement after FPD connection and at the termination of the experiment.
RESULTS: The radiographic examination revealed that the marginal bone level was well preserved at both test and control implants during the entire 16-month period. The degree of bone-implant contact within the marginal portion of the implants was significantly higher at the test (microthread) implants (81.8%) than at the control implants (72.8%).
CONCLUSIONS: It was suggested that the microthread configuration offered improved conditions for osseointegration.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16919018     DOI: 10.1111/j.1708-8208.2006.00016.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  16 in total

1.  Clinical assessment of submerged vs non-submerged implants placed in pristine bone.

Authors:  P Cardelli; F Cecchetti; M Montani; E Bramanti; C Arcuri
Journal:  Oral Implantol (Rome)       Date:  2014-05-19

2.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

3.  A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants.

Authors:  Hee-Jung Yun; Jung-Chul Park; Jeong-Ho Yun; Ui-Won Jung; Chang-Sung Kim; Seong-Ho Choi; Kyoo-Sung Cho
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

Review 4.  Relationship between dental implant macro-design and osseointegration: a systematic review.

Authors:  Simone Kreve; Izabela Ferreira; Mariana Lima da Costa Valente; Andréa Cândido Dos Reis
Journal:  Oral Maxillofac Surg       Date:  2022-09-29

5.  Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia.

Authors:  Omer Cohen; Zeev Ormianer; Haim Tal; Daniel Rothamel; Miron Weinreb; Ofer Moses
Journal:  Clin Oral Investig       Date:  2016-03-02       Impact factor: 3.573

6.  Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs.

Authors:  Yee-Seo Kwon; Hee Namgoong; Jung-Hoon Kim; In Hee Cho; Myung Duk Kim; Tae Gwan Eom; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

7.  A 5-year retrospective clinical study of the Dentium implants.

Authors:  Jeong-Yol Lee; Hyo-Jin Park; Jong-Eun Kim; Yong-Geun Choi; Young-Soo Kim; Jung-Bo Huh; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

8.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

9.  The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium.

Authors:  Omer Cohen; Dieter D Bosshardt; Evegeny Weinberg; Gil Slutzkey; Ofer Moses
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

10.  The influence of thread geometry on biomechanical load transfer to bone: A finite element analysis comparing two implant thread designs.

Authors:  Manisha G Herekar; Viraj N Patil; Shahnawaz S Mulani; Megha Sethi; Omkar Padhye
Journal:  Dent Res J (Isfahan)       Date:  2014-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.